background image

 

Power Door Locks: 3 Pin 22 Gauge (optional)  

 

Blue Wire (-) Negative Door Unlock Output  

Connect to factory unlock relay or to relay to activate motors.  
 

Green Wire: (-) Negative Door Lock Output  

Connect ot factory lock relay or to relay to activate motors.  
 

Red Wire (+) +12Volts Constant  

Connect to terminal 86 of after market relay for activating positive, reverse polarity and after market door 
locking systems. DO NOT USE THIS RED WIRE FOR MAIN POWER TO ACTIVATE DOOR LOCK 
MOTORS.  
 

Programming Dip Switches  

There are 4 dip switches under the access door of the control module for pre installation programming.  

Dip Switch #1: Door Lock/Unlock Pulse Time

  

ON: Pulse time = .75 seconds  
OFF: Pulse Time = 3 seconds  

Dip Switch #2: Ignition Controlled Lock/Unlock

  

ON: Lock/Unlock with ignition  
OFF: "NO" Lock/Unlock with ignition  

Dip Switch #3: Passive Arming Locks

  

ON: Doors lock when system arms passively  
OFF: Doors do not lock when system arms passively  

Dip Switch #4: Passive / Active Arming Select

  

ON: Alarm arms automatically 30 seconds after last door is closed (PASSIVE)  
OFF: Alarms arms only with remote control (ACTIVE)  
 
 

Transmitter Programming  

This system uses code learning to learn up to 3 different transmitter codes. Follow these 4 simple steps 
to program a transmitter to your system.  
1. Turn ignition switch on - off - on - off - on. Siren will chirp once.  
2. Push the Valet/Override switch for 5 seconds until the siren chirps 3 times. Release the Valet Switch.  
3. Press the Large Button or button #1 of the transmitter - The Siren will chirp to confirm programming. 
Repeat this procedure within 5 seconds for up to 2 additional transmitters.  
4. Turn off ignition.  
Note 1: If only one transmitter is being programmed, continue holding button #1 until dash LED flashes 4 
times. This means the system has exited program mode. Holding the transmitter button until the LED 
flashes prevents unauthorized code and noise from entering the system.  
Note 2: Program mode is exited automatically after 5 seconds of last code transmission or once three 
new codes have been programmed. LED will flash 4 times indicating program mode has terminated.  
 