![CRIFFER Vibrate Operation Manual Download Page 45](http://html1.mh-extra.com/html/criffer/vibrate/vibrate_operation-manual_2685525045.webp)
www.criffer.com
45
After saving the measurement on the computer, the software will display the
screen below for analysis of the data collected during measurement. The header
will display the event number, task name, date of the execution, sensor type,
measuring time, paused time, exposure time, time weighting, sensor’s name,
serial number, sensitivity, K factor and weighting of axes.
The measurement results are displayed on the left side of the software, which
are Are, Aren, FC, VDVexp (X), VDVexp (Y), VDVexp (Z) and the VDVR. It
also has a field to inform the workday of the worker evaluated.
In the central part of the screen are displayed the time of each record, the recor-
ding interval, the acceleration of each axis, the resulting average acceleration, the
VDV per axis, the crest factor per axis and the acceleration x time graph.
10. Analysing assessment data