![Crewsaver VOYAGER 275N Service Manual Download Page 32](http://html1.mh-extra.com/html/crewsaver/voyager-275n/voyager-275n_service-manual_2685423032.webp)
Servicing Manual: Crewsaver Voyager 275 Lifejacket
Project No: 00154
Date: November 2016
Issue No: 2
Page
of 36
32
8
Section
Fig 8.2 Crewsaver Mk5 Operating Head
With the firing capsule fitted, fit the retaining clip. The clip is
fitted by pressing it over the firing arm and in to the recess
either side in the centre of the operating head. The clip will
click into place, thereby preventing the arm from moving.
The Crewsaver Mk5 and United Moulders Mk5 heads use
different retaining clips which are not interchangeable.
Fig. 8.2.3
Fig. 8.2.4
Fit the new firing capsule onto the operating head. Capsules fitted on
the Crewsaver Mk5 head are navy blue in colour. The capsule should
be screwed tight to the end. Make a note of the batch number and
manufacture date on to the service record sheet.
If the lifejacket is fitted with a United Moulders Mk5 head a M5i firing
capsule must be fitted. These are black in colour.
Fig. 8.2.2
Fig. 8.2.1
Check that the cylinder sealing gasket in the
end of the operating head has been correctly
fitted, or replaced if necessary. Fit the 60
gram CO cylinder. Ensure that the cylinder
2
has been check weighed before fitting to the
lifejacket. Fit the gas cylinder to the firing
mechanism using the torque wrench (4Nm)
and head adaptor from the tool kit. The
cylinder is gripped in one hand and the head
tightened using the torque wrench held in the