Servicing Manual: Crewsaver Voyager 275 Lifejacket
Project No: 00154
Date: November 2016
Issue No: 2
Page
of 36
16
Fig 3.2 Hammar Operating Head
1
1.
Place the lifejacket (PFD) on a
smooth, flat surface and wipe off
any water. Hold the gas cylinder
through the fabric, using one
hand.
2a
Locking ring
Key
2b
2.
Insert metal key as shown in 2a and turn the key counter-clockwise
(2b) between black locking ring and labelled yellow cap. The black
locking ring will now turn counter-clockwise.
Fig. 3.2.1
Fig. 3.2.2
Cap
3a
3b
3.
Now turn black locking ring counter-clockwise (3a) and lift cap (3b).
(cap = yellow inflator operating head) Dispose of used cap.
Inflator body
Sealing ring
Red Indicator
4
4.
Squeeze sealing ring to elongate
and remove the inflator body
through the sealing ring. Dispose
of used inflator body in an
environmentally approved manner.
Please Note: The operating head may not match the images above, but the processes are always as above.
Fig. 3.2.3
Fig. 3.2.4
Section
3