background image

G-Series Touchpanel Interface  

Crestron Isys

®

 

TPS-G-TPI 

 

 

Use the following instructions to create the IP table. 

1. Select 

Functions

 

| IP Table Setup

 from the Toolbox menu bar. 

“IP Table” Window 

 

2.  If the interface already has an IP table, it is displayed at the top of the 

window. 

3. Click 

Add Entry t

o add a new IP table entry or select an existing IP entry 

from the list and click 

Modify Entry

. Up to 252 entries can be listed on a 

interfaces IP table. Click 

Remove [Del] 

to remove a selected IP entry or 

click 

Clear List

 to remove all of the entries from the IP table.  

NOTE: 

IP table entries that have not yet been sent to the device are listed in 

red. 

 

4. Click 

Load From File…

 to browse for a saved IP table. 

“Open” Window 

 

5.  To enter a new IP ID, select the hexadecimal IP ID of the control system 

from the 

IP ID 

list. The IP ID of the control system must match the IP ID 

that is specified for the interface in the SIMPL Windows program.  

     

¥

 Isys

®

 G-Series Touchpanel Interface: TPS-G-TPI  

   

Operations Guide – DOC. 6445 

48 

Summary of Contents for TPS-G-TPI

Page 1: ...Crestron Isys TPS G TPI G Series Touchpanel Interface Operations Guide...

Page 2: ...by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respectiv...

Page 3: ...Requirements for the PC 33 Programming with Crestron System Builder 34 Programming with SIMPL Windows 34 Programming with VisionTools Pro e 37 MultiByte International Characters 39 Uploading and Upgr...

Page 4: ......

Page 5: ...and high resolution computer graphics up to 1600 x 1200 The interface s screens can generate a dual Window display to view full motion video and high resolution RGB The TPS G TPI also includes built i...

Page 6: ...t 10BaseT 100BaseTX auto switching Fast Ethernet 802 3U compliant full duplex Serial mouse support for Microsoft and Kensington devices Built in Annotation Capability allows the live output of writing...

Page 7: ...ort or VGA connector and QM sound via the stereo headphone jack QuickMedia The TPS G TPI acts as both a QuickMedia QM receiver and transmitter Its two QM input ports support both video and audio as de...

Page 8: ...put 1 only QM OUT One RJ 45 QuickMedia output connector for RGBHV video and WAV audio output LAN One 8 wire RJ 45 Ethernet port with link activity LED indicators 10BaseT 100BaseTX high speed Ethernet...

Page 9: ...boots 5 Although flash memory is expandable to 192MB the current suggested maximum project size is 170MB or less Projects larger than this may load without error but may not display correctly 6 Refer...

Page 10: ...PS G TPI Physical View Front 1 70 in 4 38 cm TPS G TPI Physical Views Top 16 92 in 42 98 cm 9 94 in 25 25 cm 10 43 in 26 49 cm 17 03 in 43 26 cm View of Rear Connectors Cover Removed Isys G Series Tou...

Page 11: ...external plug not supplied for either a pair of external amplified speakers or headphones RS 232 This 6 pin RJ 11 connector mates with a 9 pin serial port of a PC The connecting cable is not supplied...

Page 12: ...4 N C 5 N C 6 RC 7 N C 8 N C 24VDC One 24 Volt DC power jack PW 2420RU power supply sold separately powers the TPS G TPI interface in lieu of Cresnet power NET The four pin 5 mm detachable terminal b...

Page 13: ...es or only contains files you want loaded to the interface prior to inserting into the interface When unknown files reside on the compact flash existing files on the interface may be overridden or era...

Page 14: ...ew compensation QM Input 2 is capable of the following QM Input 2 Maximum Cable Length SIGNAL TYPE RESOLUTION MAXIMUM CABLE LENGTH FEET Video S video 480i 300 Component 480p 300 Component 720p 300 Com...

Page 15: ...rges if support is required to identify performance deficiencies as a result of using improper wire CAUTION Use only Crestron power supplies for Crestron equipment Failure to do so could cause equipme...

Page 16: ...r three conductors NOTE For larger networks i e greater than 28 network devices it may become necessary to add a Cresnet Hub Repeater CNXHUB to maintain signal quality throughout the network Also for...

Page 17: ...PI This QM RMCRX BA does not violate the two midpoint rule as it is receiving an RGB signal from the TPS G TPI transmitter QM RMCRX BA QM MD7x2 QM MD7x2 QM Midpoints This TPS G TPI acts as both an end...

Page 18: ...move your finger when the message SETUP MODE briefly appears on the touchscreen Upon entering SETUP MODE the MAIN MENU as shown in the following illustration displays four buttons Touch Screen Calibra...

Page 19: ...be as accurate as possible Use the tip of a capped pen or the eraser end of a pencil To cancel calibration and return to the CALIBRATION MENU without saving calibration data create a calibration erro...

Page 20: ...INTERFACE MENU The Cresnet network identity number CRESNET ID also known as the Net ID is displayed on the INTERFACE MENU Net ID is the two digit hexadecimal number The hexadecimal number can range fr...

Page 21: ...able of this type of communication Select Enable to permit this protocol recognition and Disable to prohibit any CIP connection CIP must be enabled for the TPS G TPI to communicate with other Crestron...

Page 22: ...device to control the interface For convenience the RS 232 MENU Consol Port Mode also permits the selection of the RS 232 communication options RTS On Off XON XOFF On Off Baud Rate Data Bits Parity an...

Page 23: ...channel 2 when selected QM Transmitter ID Displays the ID of the QM transmitter in the range of 03 to FE Setup QM 1 Displays the QM 1 SETUP MENU By default the QM 1 SETUP MENU displays video controls...

Page 24: ...ode RGB Pressing this before pressing the Setup QM 2 button will open the QM 2 SETUP MENU in RGB mode To open the QM 1 SETUP MENU press the Setup QM 1 button from the QM SETUP MENU The QM 1 SETUP MENU...

Page 25: ...lue signals for RGB video QM 1 Preset Displays the current QM 1 Preset number Saved presets can also be called up using this control Plus and minus buttons increment the displayed value Load Preset Wi...

Page 26: ...ter Volume Key Click and WAV volume Bass and Treble in the audio mix The Play Test WAV File button plays a short audio file while the Restore Default Audio Settings button returns all audio parameters...

Page 27: ...is set to 100 the volume for any type of audio is at maximum If the Master Volume is set to 0 the value of all audio types is overridden and the interface is silent If Master Volume is a percentage s...

Page 28: ...r to the following table for additional QM AUDIO INPUT SETUP MENU details QM Audio Input Setup Details QM AUDIO INPUT SETUP MENU CONTROLS DESCRIPTION QM Audio 1 Selects the source of the QM data QM Pr...

Page 29: ...ameters have been set select the Return button to return to the SETUP MENU QM AUDIO OUTPUT SETUP MENU Refer to the following table for additional QM AUDIO OUTPUT SETUP MENU details QM Audio Output Set...

Page 30: ...ctivity to QuickMedia You can perform Auto Detect by selecting QM Audio 1 or QM Audio 2 or manually choose Video S Video Component or RGB as an input source Enable Black White can also be selected for...

Page 31: ...TUP MENU in Component mode RGB Pressing this before pressing the Setup Video 1 button will open the VIDEO 1 SETUP MENU in RGB mode Setup Video 2 Displays the VIDEO 2 SETUP MENU By default the VIDEO 2...

Page 32: ...he displayed preset number Restore Default Color Settings Restores the color settings to their original defaults Color Control When Video S Video or Component is selected as the video type these contr...

Page 33: ...tons return the controls to default position and allow manual adjustment respectively Position 4 This control allows you to set the position of the video screen the interface sends to a video device T...

Page 34: ...e support The options available from the DIAGNOSTICS MENU are numeric in nature and their interpretation is beyond the scope of this manual DIAGNOSTICS MENU Rack Ears Assembly The TPS GTPI interface i...

Page 35: ...uipment under any external load conditions shall not exceed a current limit that is suitable for the minimum wire gauge used in interconnecting cables The ratings on the connecting unit s supply input...

Page 36: ...TROL SYSTEM AND OTHER CRESNET DEVICES QM OUT QUICKMEDIA VIDEO KEYCLICK WAV OUTPUT QM IN QUICKMEDIA VIDEO AUDIO MIC INPUT QM IN QUICKMEDIA VIDEO AUDIO MIC INPUT COMPACT FLASH CARD SLOT AND DUAL PCMCIA...

Page 37: ...nterface using templates with a different look and feel this can be accomplished by making a custom template This custom template can then be used by SystemBuilder to create the final project files to...

Page 38: ...ystem logic Crestron System Builder is fully integrated with the Crestron suite of software development tools including SIMPL Windows VT Pro e Crestron Database User IR Database and User Modules Direc...

Page 39: ...ogram Refer to the latest version of the 2 Series Control System Reference Guide Doc 6256 and the SIMPL Windows help file for more details Configuration Manager is where programmers build a Crestron c...

Page 40: ...SIMPL Windows automatically changes Net ID values of a device added to a program if a duplicate device or a device with the same Net ID already exists in the program Always ensure that the hardware a...

Page 41: ...vanced VT Pro e high performance programming technique involving the TPS G TPI is the concept of multi mode objects A multi mode object i e button legend etc is an object drawn on a VT Pro e page that...

Page 42: ...deo memory allocates 24 bits for each pixel on the screen enabling each pixel to take on any one of a possible 16 7 million colors Each 24 bit value is composed of 8 bits for red 8 bits for green and...

Page 43: ...ompiling The 16 Bits checkbox converts a 24 bit or 32 bit image to 16 bits This conversion to a 16 bit image may cause the loss of some subtle shading To compensate for this use the dithering to simul...

Page 44: ...ial that the operating system understand the language Windows XP is available in many international languages and add on software is available for other versions of Windows Uploading and Upgrading NOT...

Page 45: ...resnet connection Refer to the following figure for a typical connection diagram connecting to an interface via a control system Indirect Serial Communications Setup Connections RS 232 Serial Cable Cr...

Page 46: ...tem Communications are confirmed when the network devices are displayed Network Device Tree To view a specific device expand the network device tree by clicking Expand the network device tree till the...

Page 47: ...t of the interface using Crestron Cable Number STCP 502PC Refer to page 7 for pin assignments NOTE Direct serial communication is a faster method for transferring programming and projects than indirec...

Page 48: ...s the Connection Type and select the serial settings of the device This sets the PC to the same serial settings Enter the settings and click OK For the interface the default settings are Port COM 1 Ba...

Page 49: ...e of device TCP IP Communication This section explains how to configure a TPS G TPI to communicate over Ethernet using TCP IP These procedures assume that the interface has been powered up and connect...

Page 50: ...communicating via DHCP Dynamic Host Configuration Protocol A network server uses this protocol to dynamically assign IP addresses to networked devices The DHCP client is not guaranteed to have a parti...

Page 51: ...ox and click Tools Manage Address book to display the Address Book window 6 Select the interface from the address book or click Add Entry and type a new name for the new device such as TPS 7 Click TCP...

Page 52: ...ntries can be listed on a interfaces IP table Click Remove Del to remove a selected IP entry or click Clear List to remove all of the entries from the IP table NOTE IP table entries that have not yet...

Page 53: ...systems that will control the interface 8 Click Save To File on the IP Table window to save this IP table to the PC Save As Window 9 Once all of the control systems have been listed click Send to Devi...

Page 54: ...umentation for further information about the COM ports on your PC 4 Remove and reapply power to the control system 5 If communication still cannot be established contact Crestron customer service Uplo...

Page 55: ...tart erase retrieve and upload a SIMPL program This menu also permits you to upload to compact flash or internal flash CAUTION Verify that any compact flash used either contains no files or only conta...

Page 56: ...into the interface When unknown files reside on the compact flash existing files on the interface may be overridden or erased if the interface reboots NOTE The current suggested maximum project size...

Page 57: ...l File Types sends the entire project Send Selected File Types sends only the file types that are selected Core Files are files that include interface logic join number remapping and other files relat...

Page 58: ...may load without error but may not display correctly NOTE With a browser project there is no vtz or hex file rather VT Pro e creates a web folder with the name of the project This web folder contains...

Page 59: ...ld becomes Retrieval Complete open the Network Device Tree window the firmware upgrade function is also available in the SMW Program Tree window 5 Right click on the device and select Functions Firmwa...

Page 60: ...play in Firmware File dropdown on the Firmware window 9 Click the Send button on the Firmware window and the File Transfer window will open File Transfer Window 10 The Firmware window reopens indicati...

Page 61: ...e screen to remove the message and verify correct wiring to all connectors Incorrect configuration parameters Enter Setup and verify parameters Interface Cresnet ID is not set to match the Net ID in t...

Page 62: ...ate specific information or have questions after reviewing this guide please take advantage of Crestron s award winning customer service team by calling the Crestron corporate headquarters at 1 888 CR...

Page 63: ...ands data or instructions from or to another computer b for local campus or wide area network internet or web hosting services or c pursuant to any rental sharing or service bureau arrangement The Sof...

Page 64: ...inety 90 days from the date of receipt and b that any hardware accompanying the Software will be subject to its own limited warranty as stated in its accompanying written material Crestron shall at it...

Page 65: ...scent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent...

Page 66: ...Crestron Electronics Inc Operations Guide DOC 6445 15 Volvo Drive Rockleigh NJ 07647 2014202 Tel 888 CRESTRON 02 06 Fax 201 767 7576 Specifications subject to www crestron com change without notice...

Reviews: