CLC-FANDELVEX-W
infiNET EX
®
Fan Controller
Installation Guide
Description
The Crestron
®
CLC-FANDELVEX-W is an infiNET EX fan and light controller. The compact
design allows it to securely fit in a fan canopy.
Refer to the following table for specifications for the CLC-FANDELVEX-W.
Installation
WARNING
: To avoid fire, shock, or death, turn off the power at the circuit breaker or
fuse and test that the power is off before wiring!
WARNING
: To reduce the risk of electric shock, install the CLC-FANDELVEX-W with an
isolating wall control or switch.
CAUTION
: To reduce the risk of overheating and possible damage to other equipment,
do not install to control a receptacle.
NOTES
: Observe the following points:
• Install and use this prodct in accordance with appropriate electrical codes and
regulations.
• A licensed electrician should install this product.
• Do not install in a damp or moist environment. This product is for indoor use only.
NOTE
: Before using the CLC-FANDELVEX-W, ensure the device is using the latest
firmware. Check for the latest firmware for the CLC-FANDELVEX-W at
www
.
crestron
.
com
/
firmware. Firmware is loaded onto the device using Crestron
Toolbox™ software.
NOTE
: Refer to the documentation for the fan for proper installation or disassembly and
reassembly.
NOTE
: Using the fan’s hardware controls, set the fan to high speed and the lights to on.
NOTE
: Remove any pre-installed fan remote controller before installing the
CLC-FANDELVEX.
Install the CLC-FANDELVEX-W after all connections have been made. The
CLC-FANDELVEX-W can be inserted into most common fan canopies. Refer to the
following illustration for details.
Additional Resources
Visit the product page on the Crestron website (www.crestron.com)
for additional information and the latest firmware updates. Use a QR
reader application on your mobile device to scan the QR image.
To Junction Box
CLC-FANDELVEX-W
Ceiling Fan
Mounting
Bracket
To Junction Box
CLC-FANDELVEX-W Installed in Fan Canopy
The CLC-FANDELVEX-W has a multifunction ACQUIRE button and STATUS, LIGHT, and
FAN LEDs. Their functions are described below.
The ACQUIRE button:
• Allows the device to connect to the infiNET EX network. Refer to the “Wireless
Communications” section for details.
• Press to toggle the dimming load between on and off.
• Press to exit Identify mode.
The STATUS LED:
• Illuminates green to indicate it is receiving power.
• Flashes green to indicate infiNET EX acquire status.
• Flashes red to indicate error conditions.
NOTE
: The green LED extinguishes after 1 minute. The red LED extinguishes
when the error is cleared.
The LIGHT LED:
• Illuminates to indicate that a command was received to turn on the light.
NOTE
: The LIGHT LED extinguishes after 1 minute.
The FAN LED:
• Illuminates to indicate that a command was received to turn on the fan.
NOTE
: The FAN LED extinguishes after 1 minute.
SPECIFICATION
DETAILS
Current Ratings
Fan Load
120 Vac, 0.8 A, 60 Hz
Light Load
120 Vac, 200 W, 60 Hz
(100 W Max for CFL or LED Loads)
Load Types
Dimmed incandescent, CFL, LED, tungsten,
electronic low voltage
NOTE
: Do not connect to magnetic low-voltage
type loads.
Environmental
Temperature
32° to 104 °F (0° to 40 °C)
Humidity
10% to 90% RH (noncondensing)