infiNET™ SWITCHES

 

Physical view of CLW-SW4RF/-SWS4RF  
(clockwise from top; Top, Side, and Front)  

FCC ID: EROCWD1011 

RUN

SET

OFF

1.75 in

(4.45 cm)

2.38 in

(6.03 cm)

3.28 in

(8.32 cm)

3.81 in

(9.68 cm)

4.13 in

(10.48 cm)

1.88 in

(4.77 cm)

2.70 in

(6.86 cm)

1.50 in

(3.81 cm)

 

Compliance Statement (Part 15.19 ) 

This device complies with Part 15 of the FCC Rules. 
Operation is subject to the following two conditions: 

1.  This device may not cause harmful interference, and 

2.  This device must accept any interference received, 

including interference that may cause undesired 
operation. 

Warning (Part 15.21) 

Changes or modifications not expressly approved by the 
party responsible for compliance could void the user’s 
authority to operate the equipment. 

RF Exposure (OET Bulletin 65) 

To comply with FCC's RF exposure limits for general 
population / uncontrolled exposure, this transmitter must 
be installed to provide a separation distance of at least 20 
cm from all persons and must not be co-located or 
operating in conjunction with any other antenna or 
transmitter. 

Physical view of CLW-SLVS1RF (clockwise from top; Top, 
Side, and Front) 

Industry Canada Statement

 

The term "IC" before the certification/registration number 
only signifies that the Industry Canada technical 
specifications were met. 
IC: 5683A-CWD1011 

1.75 in

(4.45 cm)

3.81 in

(9.68 cm)

4.13 in

(10.48 cm)

3.28 in

(8.32 cm)

1.88 in

(4.77 cm)

2.70 in

(6.86 cm

1.50 in

(3.81 cm)

 

Important Notes 

Read before installation. 

• 

Codes: Install in accordance with all local and 
national electrical codes. 

• 

CAUTION

:  TO REDUCE THE RISK OF 

OVERHEATING AND POSSIBLE DAMAGE 
TO OTHER EQUIPMENT, DO NOT INSTALL 
TO CONTROL A RECEPTACLE. 

• 

Wiring: Use copper wire only. For supply 
connection, use wires rated for at least 75°C. 

• 

Load Type: The -SW1RF, -SW4RF, -SWS1RF,  
-SWS4RF, and -SLVS1RF are designed for use 
with permanently installed incandescent, 
fluorescent (non-dimmable), low voltage, 
neon/cold cathode, HID, ceiling fan, or tungsten 
halogen lighting. 

These devices mount in a standard wallbox and are 
covered using a decorative faceplate (not included). 

Industry Compliance 

This product is Listed to applicable UL Standards and 
requirements by Underwriters Laboratories Inc.  

• 

Temperature: The -SW1RF, -SW4RF,  
-SWS1RF, -SWS4RF, and -SLVS1RF are 
designed to be used where temperatures are 
between 32° to 104°F (0° to 40°C). 

E239013 

 

Installation Guide - DOC. 6293A 

infiNET™ Wall Box Switch:  CLW-SW1/4RF, SWS1/4RF, & SLVS1RF  

  3  

 

Summary of Contents for infiNET CLW-SLVS1RF

Page 1: ...ve unit that when used in conjunction with the SWS1RF or the SWS4RF acts as an additional switch control point in a multi switch single circuit application It does not connect to a Cresnet system and cannot be used without a SWS1RF or SWS4RF The SLVS1RF does not have a mode selection switch It will emulate the RUN mode of the SWS1RF even if connected to a SWS4RF unless the mode selection switch of...

Page 2: ... the latest Crestron Product Catalog for a complete list of 2 Series control systems 4 Refer to Derating Charts for Multigang Installations on page 4 Physical view of CLW SW1RF SWS1RF clockwise from top Top Side and Front 5 VA ratings are for input power to the transformer If you do not know the input power requirement of the transformer use the bulb s wattage rating to determine proper rating 1 7...

Page 3: ...ide and Front Industry Canada Statement The term IC before the certification registration number only signifies that the Industry Canada technical specifications were met IC 5683A CWD1011 1 75 in 4 45 cm 3 81 in 9 68 cm 4 13 in 10 48 cm 3 28 in 8 32 cm 1 88 in 4 77 cm 2 70 in 6 86 cm 1 50 in 3 81 cm Important Notes Read before installation Codes Install in accordance with all local and national el...

Page 4: ...ng installations several controls are grouped horizontally in one wallbox For a smooth appearance one piece multigang faceplates not supplied can be installed VA ratings are for input power to the transformer If you do not know the input power requirement of the transformer use the bulb s wattage rating to determine proper rating 1 When combining controls in a wallbox remove inner side sections pr...

Page 5: ...uit breaker 2 Wire the switches as shown in Figure 3 on page 8 NOTE Do not connect the BLUE Slave wire to the Black Hot or RED Load wires NOTE The RED Load and BLACK Hot wires are 14 AWG The BLUE Slave and WHITE Neutral wires are 18 AWG The GREEN Ground wire is 16 AWG When installing a SWXRF or a SWSXRF without a slave follow the instructions in Wiring a SW S XRF No Slaves below If wiring a SWSXRF...

Page 6: ...witch s mode selection switch shown in the following diagrams to the RUN position and perform either of the following steps depending on the switch model Parts of CLW SW1RF SWS1RF Button Mode Selection Switch RUN SET OFF Parts of CLW SW4RF SWS4RF Button 2 Mode Selection Switch Button 4 Button 3 Button 1 RUN SET OFF Testing a SW1RF and SWS1RF With the mode selection switch in the RUN position tap t...

Page 7: ...are not covered Further Inquiries This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any If you cannot locate specific information or have questions after reviewing this guide please take advantage of Crestron s award winning customer service team by ...

Page 8: ...LW SWS1RF shown To continue a circuit past a switched light fixture to one or more duplex receptacles connect the switch as shown in the following diagram Figure 2 Adding a Duplex Receptacle Past a Switched Light Fixture Master Slave Installation Figure 3 Wiring a CLW SWSXRF CLW SWS4RF shown with a CLW SLVS1RF 8 infiNET Wall Box Switch CLW SW1 4RF SWS1 4RF SLVS1RF Installation Guide DOC 6293A ...