Crestron Green Light DIN-PWS50 Operations & Installation Manual Download Page 20

DIN Rail 50 Watt Cresnet

®

 Power Supply   

Crestron 

DIN-PWS50 

Return and Warranty Policies 

Merchandise Returns / Repair Service 

1.  No merchandise may be returned for credit, exchange or service without prior authorization 

from CRESTRON. To obtain warranty service for CRESTRON products, contact an 
authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory 
and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying 
the nature of the problem, name and phone number of contact person, RMA number and 
return address. 

2.  Products may be returned for credit, exchange or service with a CRESTRON Return 

Merchandise Authorization (RMA) number. Authorized returns must be shipped freight 
prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N.J. or its authorized subsidiaries, with 
RMA number clearly marked on the outside of all cartons. Shipments arriving freight collect 
or without an RMA number shall be subject to refusal. CRESTRON reserves the right in its 
sole and absolute discretion to charge a 15% restocking fee plus shipping costs on any 
products returned with an RMA. 

3.  Return freight charges following repair of items under warranty shall be paid by CRESTRON, 

shipping by standard ground carrier. In the event repairs are found to be non-warranty, return 
freight costs shall be paid by the purchaser. 

CRESTRON Limited Warranty 

CRESTRON ELECTRONICS, Inc. warrants its products to be free from manufacturing defects in materials 
and workmanship under normal use for a period of three (3) years from the date of purchase from 
CRESTRON, with the following exceptions: disk drives and any other moving or rotating mechanical 
parts, pan/tilt heads and power supplies are covered for a period of one (1) year; touchscreen display and 
overlay components are covered for 90 days; batteries and incandescent lamps are not covered.  
This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON 
dealer. Purchasers should inquire of the dealer regarding the nature and extent of the dealer's warranty, if 
any. 
CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any 
application other than that for which it was intended or if it has been subjected to misuse, accidental 
damage, modification or improper installation procedures. Furthermore, this warranty does not cover any 
product that has had the serial number altered, defaced or removed. 
This warranty shall be the sole and exclusive remedy to the original purchaser. In no event shall 
CRESTRON be liable for incidental or consequential damages of any kind (property or economic damages 
inclusive) arising from the sale or use of this equipment. CRESTRON is not liable for any claim made by a 
third party or made by the purchaser for a third party. 
CRESTRON shall, at its option, repair or replace any product found defective, without charge for parts or 
labor. Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the 
unexpired portion of the warranty. 
Except as expressly set forth in this warranty, CRESTRON makes no other warranties, expressed or 
implied, nor authorizes any other party to offer any warranty, including any implied warranties of 
merchantability or fitness for a particular purpose. Any implied warranties that may be imposed by law are 
limited to the terms of this limited warranty. This warranty statement supersedes all previous warranties. 

Trademark Information

 

All brand names, product names and trademarks are the sole property of their respective owners. Windows is a registered trademark 
of Microsoft Corporation. Windows95/98/Me/XP/Vista and WindowsNT/2000 are trademarks of Microsoft Corporation. 

16  

  DIN Rail Power Supply: DIN-PWS50 

Operations & Installation Guide – DOC. 6667A 

Summary of Contents for Green Light DIN-PWS50

Page 1: ...Crestron GreenLight DIN PWS50 DINRail50WattCresnet PowerSupply Operations Installation Guide ...

Page 2: ...n by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respective owners 2008 Crestron Electronics Inc ...

Page 3: ...ications 2 Specifications 3 Physical Description 4 Industry Compliance 7 Setup 8 Network Wiring 8 Installation 8 Hardware Hookup 10 Problem Solving 13 Troubleshooting 13 Check Network Wiring 14 Further Inquiries 15 Future Updates 15 Return and Warranty Policies 16 Merchandise Returns Repair Service 16 CRESTRON Limited Warranty 16 Operations Installation Guide DOC 6667A Contents i ...

Page 4: ......

Page 5: ...er third party DIN rail mountable devices All wiring connections are made using screw terminals positioned along the top and bottom clearly accessible from the front for easy installation and servicing Three Cresnet power ports are provided Features and Functions 50 Watt Cresnet power supply module Powers the DIN Rail series of Crestron products and other Cresnet devices Includes three Cresnet pow...

Page 6: ...net Power Supply Crestron DIN PWS50 Applications The following diagram shows a DIN PWS50 in a typical application DIN PWS50 in a Typical Application 2 DIN Rail Power Supply DIN PWS50 Operations Installation Guide DOC 6667A ...

Page 7: ...al Temperature 0º to 40º C 32º to 104º F Humidity 10 to 90 RH non condensing Heat Dissipation 26 BTU Hr Enclosure Light gray polycarbonate housing with polycarbonate label overlay UL94 V 0 rated 35 mm DIN EN 60715 rail mount DIN 43880 form factor for enclosures with 45 mm front panel cutout occupies 6 DIN module spaces 108 mm Dimensions Height 94 2 mm 3 71 in Width 106 mm 4 18 in Depth 58 mm 2 29 ...

Page 8: ...restron DIN PWS50 Physical Description This section provides information on the connections controls and indicators available on your DIN PWS50 DIN PWS50 Physical View 4 DIN Rail Power Supply DIN PWS50 Operations Installation Guide DOC 6667A ...

Page 9: ... PWS50 DIN Rail 50 Watt Cresnet Power Supply DIN PWS50 Overall Dimensions 58 mm 2 29 in 106 mm 4 18 in 94 2 mm 3 71 in 90 mm 3 55 in 2 3 1 4 Operations Installation Guide DOC 6667A DIN Rail Power Supply DIN PWS50 5 ...

Page 10: ...icates 24 Volts DC output at all NET ports extinguished when fuse is blown 3 NET 3 4 pin 3 5 mm detachable terminal blocks paralleled Cresnet power output ports with data pass through Connects to Cresnet control network Pin 1 24 Power 24 Volts DC Pin 2 Y Data Pin 3 Z Data Pin 4 G Ground 4 FUSE Main fuse located under cover T3 15AH 5 x 20 mm 250V 3 15 A time lag ceramic cartridge Interface connecto...

Page 11: ...ules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installa...

Page 12: ...er DIN HUB is advised whenever the number of Cresnet devices on a network exceeds 20 or when the combined total length of Cresnet cable exceeds 914 meters 3000 feet For more details refer to Check Network Wiring which starts on page 14 Installation The DIN PWS50 must be installed by a licensed electrician in accordance with all national and local codes CAUTION This equipment is for indoor use only...

Page 13: ...rail products it may be necessary to use a flat head screwdriver to pull the DIN rail release tab while snapping the device onto the DIN rail To remove the DIN PWS50 from the DIN rail use a small flat object i e a flat head screwdriver to pull the DIN rail release and tilt the bottom of the DIN PWS50 away from the DIN rail NOTE Certain third party DIN cabinets provide space for an informational la...

Page 14: ...o do so may result in serious injury or damage to the device Restore power after all connections have been made NOTE Install in accordance with all local and national electric codes NOTE High voltage connections accept 2 5 mm2 12 AWG wire Wire should be stripped to 8 mm 1 3 inch Tighten terminal blocks to 0 5 Nm 5 in lbs NOTE Use copper wire only For high voltage connections use wire rated for at ...

Page 15: ...ly Hardware Connections for the DIN PWS50 NET TO CONTROL SYSTEM AND OTHER CRESNET DEVICES 100 240 50 60Hz FROM AC POWER LINE FUSE IS LOCATED UNDER THIS COVER POWER TO OTHER DEVICES Operations Installation Guide DOC 6667A DIN Rail Power Supply DIN PWS50 11 ...

Page 16: ...ft corner To replace the fuse 1 Disconnect power to the DIN PWS50 2 Remove the cover from the lower left corner on the front of the DIN PWS50 3 Remove the defective fuse from the fuse holder and replace with a new one CAUTION Use only time lag type fuses 3 15 Amps 250 Volts Failure to do so may cause damage to the DIN PWS50 4 Replace the fuse cover 5 Connect power to the DIN PWS50 12 DIN Rail Powe...

Page 17: ...oting TROUBLE POSSIBLE CAUSE S CORRECTIVE ACTION 24VDC LED does not illuminate DIN PWS50 is not receiving power Verify the DIN PWS50 is connected to an AC power line Fuse is blown Replace fuse with T3 15AH 5 x 20 mm 250 V 3 15 A time lag ceramic cartridge Refer to Fuse Replacement on page 12 Output is short circuited Disconnect all output connectors LED will light if problem was a short circuit on...

Page 18: ...k unit to be connected must be taken into consideration Use Crestron Certified Wire only If Cresnet units are to be daisy chained on the run the Cresnet power usage of each network unit to be daisy chained must be added together to determine the Cresnet power usage of the entire chain If the unit is home run from a Crestron system power supply network port the Cresnet power usage of that unit is t...

Page 19: ...e combined total length of Cresnet cable exceeds 914 meters 3000 feet Further Inquiries If you cannot locate specific information or have questions after reviewing this guide please take advantage of Crestron s award winning customer service team by calling Crestron at 1 888 CRESTRON 1 888 273 7876 You can also log onto the online help section of the Crestron website www crestron com onlinehelp to...

Page 20: ...for 90 days batteries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for wh...

Page 21: ...Crestron DIN PWS50 DIN Rail 50 Watt Cresnet Power Supply Operations Installation Guide DOC 6667A DIN Rail Power Supply DIN PWS50 17 This page is intentionally left blank ...

Page 22: ...DIN Rail 50 Watt Cresnet Power Supply Crestron DIN PWS50 This page is intentionally left blank 18 DIN Rail Power Supply DIN PWS50 Operations Installation Guide DOC 6667A ...

Page 23: ...Crestron DIN PWS50 DIN Rail 50 Watt Cresnet Power Supply This page is intentionally left blank Operations Installation Guide DOC 6667A DIN Rail Power Supply DIN PWS50 19 ...

Page 24: ...ron Electronics Inc Operations Installation Guide DOC 6667A 15 Volvo Drive Rockleigh NJ 07647 2020749 Tel 888 CRESTRON 05 08 Fax 201 767 7576 Specifications subject to www crestron com change without notice ...

Reviews: