background image

Crestron 

DIN-PWS50

 

DIN Rail 50 Watt Cresnet

®

 Power Supply

 

Hardware Connections for the DIN-PWS50 

NET:

TO CONTROL SYSTEM AND

OTHER CRESNET DEVICES

100-240~50/60Hz:

FROM AC

POWER LINE

FUSE IS LOCATED
UNDER THIS COVER

POWER TO

OTHER DEVICES

 

 
 
 
 
 
 
 
 

Operations & Installation Guide – DOC. 6667A 

DIN Rail Power Supply: DIN-PWS50  

  11 

Summary of Contents for Green Light DIN-PWS50

Page 1: ...Crestron GreenLight DIN PWS50 DINRail50WattCresnet PowerSupply Operations Installation Guide ...

Page 2: ...n by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respective owners 2008 Crestron Electronics Inc ...

Page 3: ...ications 2 Specifications 3 Physical Description 4 Industry Compliance 7 Setup 8 Network Wiring 8 Installation 8 Hardware Hookup 10 Problem Solving 13 Troubleshooting 13 Check Network Wiring 14 Further Inquiries 15 Future Updates 15 Return and Warranty Policies 16 Merchandise Returns Repair Service 16 CRESTRON Limited Warranty 16 Operations Installation Guide DOC 6667A Contents i ...

Page 4: ......

Page 5: ...er third party DIN rail mountable devices All wiring connections are made using screw terminals positioned along the top and bottom clearly accessible from the front for easy installation and servicing Three Cresnet power ports are provided Features and Functions 50 Watt Cresnet power supply module Powers the DIN Rail series of Crestron products and other Cresnet devices Includes three Cresnet pow...

Page 6: ...net Power Supply Crestron DIN PWS50 Applications The following diagram shows a DIN PWS50 in a typical application DIN PWS50 in a Typical Application 2 DIN Rail Power Supply DIN PWS50 Operations Installation Guide DOC 6667A ...

Page 7: ...al Temperature 0º to 40º C 32º to 104º F Humidity 10 to 90 RH non condensing Heat Dissipation 26 BTU Hr Enclosure Light gray polycarbonate housing with polycarbonate label overlay UL94 V 0 rated 35 mm DIN EN 60715 rail mount DIN 43880 form factor for enclosures with 45 mm front panel cutout occupies 6 DIN module spaces 108 mm Dimensions Height 94 2 mm 3 71 in Width 106 mm 4 18 in Depth 58 mm 2 29 ...

Page 8: ...restron DIN PWS50 Physical Description This section provides information on the connections controls and indicators available on your DIN PWS50 DIN PWS50 Physical View 4 DIN Rail Power Supply DIN PWS50 Operations Installation Guide DOC 6667A ...

Page 9: ... PWS50 DIN Rail 50 Watt Cresnet Power Supply DIN PWS50 Overall Dimensions 58 mm 2 29 in 106 mm 4 18 in 94 2 mm 3 71 in 90 mm 3 55 in 2 3 1 4 Operations Installation Guide DOC 6667A DIN Rail Power Supply DIN PWS50 5 ...

Page 10: ...icates 24 Volts DC output at all NET ports extinguished when fuse is blown 3 NET 3 4 pin 3 5 mm detachable terminal blocks paralleled Cresnet power output ports with data pass through Connects to Cresnet control network Pin 1 24 Power 24 Volts DC Pin 2 Y Data Pin 3 Z Data Pin 4 G Ground 4 FUSE Main fuse located under cover T3 15AH 5 x 20 mm 250V 3 15 A time lag ceramic cartridge Interface connecto...

Page 11: ...ules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installa...

Page 12: ...er DIN HUB is advised whenever the number of Cresnet devices on a network exceeds 20 or when the combined total length of Cresnet cable exceeds 914 meters 3000 feet For more details refer to Check Network Wiring which starts on page 14 Installation The DIN PWS50 must be installed by a licensed electrician in accordance with all national and local codes CAUTION This equipment is for indoor use only...

Page 13: ...rail products it may be necessary to use a flat head screwdriver to pull the DIN rail release tab while snapping the device onto the DIN rail To remove the DIN PWS50 from the DIN rail use a small flat object i e a flat head screwdriver to pull the DIN rail release and tilt the bottom of the DIN PWS50 away from the DIN rail NOTE Certain third party DIN cabinets provide space for an informational la...

Page 14: ...o do so may result in serious injury or damage to the device Restore power after all connections have been made NOTE Install in accordance with all local and national electric codes NOTE High voltage connections accept 2 5 mm2 12 AWG wire Wire should be stripped to 8 mm 1 3 inch Tighten terminal blocks to 0 5 Nm 5 in lbs NOTE Use copper wire only For high voltage connections use wire rated for at ...

Page 15: ...ly Hardware Connections for the DIN PWS50 NET TO CONTROL SYSTEM AND OTHER CRESNET DEVICES 100 240 50 60Hz FROM AC POWER LINE FUSE IS LOCATED UNDER THIS COVER POWER TO OTHER DEVICES Operations Installation Guide DOC 6667A DIN Rail Power Supply DIN PWS50 11 ...

Page 16: ...ft corner To replace the fuse 1 Disconnect power to the DIN PWS50 2 Remove the cover from the lower left corner on the front of the DIN PWS50 3 Remove the defective fuse from the fuse holder and replace with a new one CAUTION Use only time lag type fuses 3 15 Amps 250 Volts Failure to do so may cause damage to the DIN PWS50 4 Replace the fuse cover 5 Connect power to the DIN PWS50 12 DIN Rail Powe...

Page 17: ...oting TROUBLE POSSIBLE CAUSE S CORRECTIVE ACTION 24VDC LED does not illuminate DIN PWS50 is not receiving power Verify the DIN PWS50 is connected to an AC power line Fuse is blown Replace fuse with T3 15AH 5 x 20 mm 250 V 3 15 A time lag ceramic cartridge Refer to Fuse Replacement on page 12 Output is short circuited Disconnect all output connectors LED will light if problem was a short circuit on...

Page 18: ...k unit to be connected must be taken into consideration Use Crestron Certified Wire only If Cresnet units are to be daisy chained on the run the Cresnet power usage of each network unit to be daisy chained must be added together to determine the Cresnet power usage of the entire chain If the unit is home run from a Crestron system power supply network port the Cresnet power usage of that unit is t...

Page 19: ...e combined total length of Cresnet cable exceeds 914 meters 3000 feet Further Inquiries If you cannot locate specific information or have questions after reviewing this guide please take advantage of Crestron s award winning customer service team by calling Crestron at 1 888 CRESTRON 1 888 273 7876 You can also log onto the online help section of the Crestron website www crestron com onlinehelp to...

Page 20: ...for 90 days batteries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for wh...

Page 21: ...Crestron DIN PWS50 DIN Rail 50 Watt Cresnet Power Supply Operations Installation Guide DOC 6667A DIN Rail Power Supply DIN PWS50 17 This page is intentionally left blank ...

Page 22: ...DIN Rail 50 Watt Cresnet Power Supply Crestron DIN PWS50 This page is intentionally left blank 18 DIN Rail Power Supply DIN PWS50 Operations Installation Guide DOC 6667A ...

Page 23: ...Crestron DIN PWS50 DIN Rail 50 Watt Cresnet Power Supply This page is intentionally left blank Operations Installation Guide DOC 6667A DIN Rail Power Supply DIN PWS50 19 ...

Page 24: ...ron Electronics Inc Operations Installation Guide DOC 6667A 15 Volvo Drive Rockleigh NJ 07647 2020749 Tel 888 CRESTRON 05 08 Fax 201 767 7576 Specifications subject to www crestron com change without notice ...

Reviews: