Crestron
DM-MD64X64/DM-MD128X128
DigitalMedia Switchers
Operations & Installation Guide – DOC. 7318D
DigitalMedia Switchers: DM-MD64X64/DM-MD128X128
•
27
Identity Code
The IP ID can be set from the front panel touch screen or from a web browser. The
IP IDs of multiple DM switchers in the same system must be unique.
When setting the IP ID, consider the following:
•
The IP ID of each unit must match an IP ID specified in the Crestron
Studio™ or SIMPL Windows program.
•
Each device using IP to communicate with a control system must have a
unique IP ID.
DigitalMedia devices that receive their IP address configuration via the DM switcher
also receive their IP table configuration from the DM-MD64X64.
Installation
Ventilation
The DM switcher should be used in a well-ventilated area. The venting holes should
not be obstructed under any circumstances.
To prevent overheating, do not operate this product in an area that exceeds the
environmental temperature range listed in the table of specifications. Consider using
forced air ventilation and/or increasing the spacing between units to reduce
overheating.
Contact with thermal insulating materials should be avoided on all sides of the unit.
NOTE:
If the DM switcher detects an unsafe operating temperature, it will enter
low power protection mode and, as a result, video functionality will be disabled.
Rack Mounting
The DM switcher can be mounted in a rack or stacked with other equipment.
WARNING:
Do not lift the DM switcher using the power supply handles. Doing so
will damage the unit and can cause bodily injury.
NOTE:
The DM switcher has rack ears integrated into the chassis. They cannot be
removed.
NOTE:
To facilitate installation, four handles are provided on the front and on the
rear of the DM-MD128X128. If desired, the handles on the front of the unit can be
removed after installation using a Phillips head screwdriver.
To attach the unit to a rack, use four screws (not supplied) for each rack ear.
WARNING:
To prevent bodily injury when mounting or servicing this unit in a
rack, observe the following guidelines:
•
When mounting this unit in a partially filled rack, load the rack from the
bottom to the top with the heaviest component at the bottom of the rack.
•
If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the
rack.
Summary of Contents for DigitalMedia DM-MD128X128
Page 1: ...Crestron DM MD64X64 DM MD128X128 DigitalMedia Switchers Operations Installation Guide ...
Page 4: ......
Page 6: ......