Power Requirements 

 

CAUTION:

  Use only Crestron power supplies for Crestron equipment. 

Failure to do so could cause equipment damage or void the Crestron 
warranty. 

CAUTION:

  If using 24 VDC power from a Cresnet network to power 

the CSP-RS232I, sufficient power must be provided. Insufficient power 
can lead to unpredictable results or damage to the equipment. Please use 
the Crestron Power Calculator to help calculate how much power is 
needed for the system (

www.crestron.com/calculators

). 

When calculating the length of wire for a particular Cresnet run, the wire 
gauge and the Cresnet power usage of each network unit to be connected 
must be taken into consideration. Use Crestron Certified Wire only. If 
Cresnet units are to be daisy-chained on the run, the Cresnet power usage 
of each network unit to be daisy-chained must be added together to 
determine the Cresnet power usage of the entire chain. If the unit is 
home-run from a Crestron system power supply network port, the 
Cresnet power usage of that unit is the Cresnet power usage of the entire 
run. The wire gauge and the Cresnet power usage of the run should be 
used in the following equation to calculate the cable length value on the 
equation’s left side. 

Cable Length Equation 

L = Length of run (or chain) in feet
R = 6 Ohms (Crestron Certified Wire: 18 AWG (0.75 MM  ))

or 1.6 Ohms (Cresnet HP: 12 AWG (4 MM  ))

P = Cresnet power usage of entire run (or chain)

2

2

L <

40,000

R x P

Where:

 

Make sure the cable length value is less than the value calculated on the 
right side of the equation. For example, a Cresnet run using 18 AWG 
Crestron Certified Wire and drawing 20 watts should not have a length of 
run more than 333 feet. If Cresnet HP is used for the same run, its length 
could extend to 1250 feet. 

 

Operations & Installation Guide – DOC. 6634A 

RS-232 Isolator: CSP-RS232I  

  11 

Summary of Contents for CSP-RS232I

Page 1: ...Crestron CSP RS232I RS 232Isolator Operations Installation Guide...

Page 2: ...by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respectiv...

Page 3: ...ysical Description 3 Industry Compliance 8 Setup 9 Installation 9 Hardware Hookup 9 Problem Solving 10 Troubleshooting 10 Power Requirements 11 Further Inquiries 12 Future Updates 12 Return and Warran...

Page 4: ......

Page 5: ...troller or irrigation system the CSP RS232I can prevent damage to the control system in the event of a near lightning strike ground loop or short from a high voltage line Features and Functions Recomm...

Page 6: ...W 1205 or PW 1210RU power supply sold separately 1 Watt 0 04 Amp 24 Volts DC Enclosure Steel surface mount box with 2 integral mounting flanges printed label Environmental Temperature Humidity Heat Di...

Page 7: ...escription This section provides information on the connections controls and indicators available on your CSP RS232I CSP RS232I Physical View Top CSP RS232I Physical View Bottom Operations Installatio...

Page 8: ...or Crestron CSP RS232I CSP RS232I Overall Dimensions 3 76 in 9 55 cm 3 40 in 8 64 cm 1 75 in 4 45 cm 4 52 in 11 48 cm 1 34 in 3 40 cm 1 4 2 5 3 4 RS 232 Isolator CSP RS232I Operations Installation Gui...

Page 9: ...TS signals Supports up to 115 2k baud PIN DESCRIPTION 1 No Connection 2 RX Input from device s TX output 3 TX Output from device s RX input 4 No Connection 5 Isolated Signal Ground 6 No Connection 7 R...

Page 10: ...o Connection 2 RX Output to control system s RX input 3 TX Input to control system s TX output 4 No Connection 5 Signal Ground 6 No Connection 7 RTS Input to control system s RTS output 8 CTS Output t...

Page 11: ...cated power supply not included 5 PWR2 12VDC 1 2 5mm barrel DC power jack 12 Volt DC power input PW 1205 or PW 1210RU power supply sold separately 1 Interface connector for PWR 24VDC port is provided...

Page 12: ...mful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful...

Page 13: ...nnections have been made When making connections to the CSP RS232I note the following Use Crestron power supplies for Crestron equipment Power can be supplied to either the 12 VDC port or the 24 VDC p...

Page 14: ...is not receiving sufficient power Use the Crestron Power Calculator to help calculate how much power is needed for the system PWR LED does not illuminate Device is not receiving power Connect power t...

Page 15: ...ork unit to be daisy chained must be added together to determine the Cresnet power usage of the entire chain If the unit is home run from a Crestron system power supply network port the Cresnet power...

Page 16: ...w crestron com onlinehelp to ask questions about Crestron products First time users will need to establish a user account to fully benefit from all available features Future Updates As Crestron improv...

Page 17: ...ys batteries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regardin...

Page 18: ...RS 232 Isolator Crestron CSP RS232I 14 RS 232 Isolator CSP RS232I Operations Installation Guide DOC 6634A This page is intentionally left blank...

Page 19: ...Crestron CSP RS232I RS 232 Isolator This page is intentionally left blank Operations Installation Guide DOC 6634A RS 232 Isolator CSP RS232I 15...

Page 20: ...on Electronics Inc Operations Installation Guide DOC 6634A 15 Volvo Drive Rockleigh NJ 07647 2019289 Tel 888 CRESTRON 02 08 Fax 201 767 7576 Specifications subject to www crestron com change without n...

Reviews: