Crestron
CP3 & CP3N
3-Series Control Systems
Operations Guide
Page 1: ...Crestron CP3 CP3N 3 SeriesControlSystems Operations Guide ...
Page 2: ...tron is not responsible for errors in typography or photography This document was written by the Technical Publications department at Crestron 2013 Crestron Electronics Inc Regulatory Compliance These products are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc As of the date of manufacture the CP3 and CP3N have been tested and found to comply with specification...
Page 3: ...dware Hookup 14 Additional Configuration 17 Uploading and Upgrading 18 Establishing Communication 18 Control Subnet CP3N Only 19 Programs and Firmware 20 Configure for Operations 21 Set Date Time 21 Online Configuration 21 Problem Solving 23 Troubleshooting 23 Check Network Wiring 24 Reference Documents 25 Further Inquiries 25 Future Updates 26 Return and Warranty Policies 27 Merchandise Returns R...
Page 4: ......
Page 5: ...where noted Features and Functions Continued on following page Next generation control system Core 3 OS substantially faster and more powerful than other control systems Exclusive modular programming architecture Vector floating point coprocessor Onboard 512 MB RAM and 4 GB flash memory Expandable storage up to 1 TB Rear panel memory card slot High speed USB 2 0 host port Industry standard Etherne...
Page 6: ...ms simultaneously This exclusive programming architecture lets programmers independently develop and run device specific programs for AV lighting HVAC security etc allowing for the optimization of each program and allowing changes to be made to one program without affecting the whole As the system grows processing resources can easily be shifted from one 3 Series processor to another without rewri...
Page 7: ...t on the CP3N provides a single point connection to the customer s LAN requiring just one IP address for the complete control system The LAN port allows full interconnectivity between devices on the local subnet with other devices systems servers and WAN Internet connections outside the local subnet For sensitive applications that require absolute security the entire Control Subnet can be complete...
Page 8: ...three bidirectional COM ports and eight IR ports to interface directly with all of the centralized AV sources video displays and other devices Eight programmable relay ports are included for controlling window shades projection screens lifts power controllers and other contact closure actuated equipment Eight Versiport I O ports enable the integration of occupancy sensors power sensors door switch...
Page 9: ...ew applications Control Subnet CP3N Only 10 100 1000 Mbps Ethernet auto switching auto negotiating auto discovery full half duplex DHCP server DNS server port forwarding Isolation mode Cresnet Cresnet master mode USB Supports USB HID and USB mass storage class devices via rear panel USB 2 0 host port supports computer console via front panel USB 2 0 device port RS 232 422 485 For 2 way device cont...
Page 10: ...tive BACnet IP Interface License C2N HBLOCK Cresnet Network Distribution Block CEN SW POE 16 16 Port Managed PoE Switch CEN SW POE 24 24 Port Managed PoE Switch CEN SW POE 5 5 Port PoE Switch CNSP XX Custom Serial Interface Cable Crestron Mobile Control App for iPhone and iPod touch Crestron Mobile Pro G Control App for iPhone iPad and Android Devices CSP LIR USB IR Learner Fusion RV Remote Asset ...
Page 11: ...trol Systems Operations Guide DOC 7316C 3 Series Control Systems CP3 CP3N 7 Physical Description This section provides information on the connections controls and indicators available on the CP3 CP3 Physical View CP3N Physical View ...
Page 12: ... Systems Crestron CP3 CP3N 8 3 Series Control Systems CP3 CP3N Operations Guide DOC 7316C CP3 and CP3N Overall Dimensions 6 56 in 17 28 in 1 70 in 44 mm 439 mm 167 mm 6 7 8 9 11 12 13 15 16 17 10 1 2 3 4 5 14 CP3 CP3N ...
Page 13: ...2 3 4 2 8 pin 3 5 mm detachable terminal blocks comprising 8 normally open isolated relays Rated 1 amp 30 volts ac dc MOV arc suppression across contacts 7 I O 1 8 1 2 3 4 5 6 7 8 G 1 9 pin 3 5 mm detachable terminal block comprising 8 Versiport digital input output or analog input ports referenced to GND Digital Input Rated for 0 24 volts dc input impedance 20 kΩ logic threshold 3 125 V low 0 and...
Page 14: ...s Up to 115 2k baud software handshaking support 11 MEMORY 1 Memory card slot Accepts up to 32 GB for memory expansion SD memory card not included 12 USB 1 USB Type A female USB 2 0 port for storage devices 13 LAN Amber Green LED Amber LED Pin 8 Pin 1 1 8 pin RJ 45 with two LED indicators 10BASE T 100BASE TX Ethernet port CP3 10 100 1000BASE T Ethernet port CP3N Left LED indicates link status Ambe...
Page 15: ...es a dedicated local network for Crestron Ethernet devices PIN SIGNAL PIN SIGNAL 1 BI_DA 5 BI_DC 2 BI_DA 6 BI_DB 3 BI_DB 7 BI_DD 4 BI_DC 8 BI_DD 15 NET G Y Z 24 1 4 pin 3 5 mm detachable terminal block Cresnet master port Outputs power to Cresnet devices if a power pack is connected to the 24 Vdc power input jack Receives Cresnet network power if no power pack is connected to the 24 Vdc power inpu...
Page 16: ...ww crestron com manuals Identity Code Net ID The Net ID of the CP3 has been factory set to 02 This Net ID is defined as the Master control system on the Cresnet network and cannot be changed IP ID The IP ID is set within the CP3 s IP table using Crestron Toolbox For information on setting an IP table refer to the Crestron Toolbox help file When setting the IP ID consider the following The IP ID of...
Page 17: ...duced Air Flow Installation of the equipment in a rack should be such that the amount of airflow required for safe operation of the equipment is not compromised Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading Circuit Overloading Consideration should be given to the connection of the equipment to the...
Page 18: ... should be attached prior to the hookup procedure Refer to the following illustration for placement of the feet Foot Placement for the CP3 Mounting Feet 2002389 QTY 4 NOTE No more than two CP3 units should be stacked Hardware Hookup Connect the Device Make the necessary connections as called out in the illustration that follows this paragraph Refer to Network Wiring on page 12 before attaching the...
Page 19: ...d I O 1 8 To Controllable Devices Hardware Connections for the CP3N Rear RELAY OUTPUT 1 8 To Contact Closure Devices IR SERIAL 1 8 To TTL RS 232 Devices COM 1 To Serial Controlled Devices COM 2 3 To Serial Controlled Devices MEMORY SD Compatible Card Slot LAN 10 100 1000BASE T Ethernet to LAN 24V DC 2 0 A From AC Power Pack Ground USB To Storage Devices NET To Cresnet Devices I O 1 8 To Controllab...
Page 20: ...ct the CONTROL SUBNET port to the LAN The CONTROL SUBNET port must only be connected to Crestron Ethernet devices Control Subnet Application The Control Subnet can host up to 64000 Crestron Ethernet devices Connect a Crestron Ethernet switch such as the CEN SWPOE 16 16 Port Managed PoE Switch sold separately to the CP3N s CONTROL SUBNET port to use as a connection point a variety of Crestron Ether...
Page 21: ...P3N 3 Series Control Systems Operations Guide DOC 7316C 3 Series Control Systems CP3 CP3N 17 Additional Configuration The CP3 can be configured from a Web browser For details refer to Online Configuration on page 21 ...
Page 22: ...Communications with the Control System in the Crestron 3 Series Control Systems Reference Guide Doc 7150 for connection details If communications cannot be established refer to Troubleshooting Communications in the same guide Establishing Communication Use Crestron Toolbox for communicating with the CP3 refer to the Crestron Toolbox help file for details There are two methods of communication USB ...
Page 23: ...o communicate with Crestron Ethernet devices on a subnet that is independent of the local area network that is connected to the LAN port When using the Control Subnet observe the following The CP3N is a DHCP server to all devices connected to the Control Subnet and assigns IP addresses as needed A DNS server is built in to the CP3N to resolve hostnames Only Crestron Ethernet devices should be conn...
Page 24: ...lbox For details on uploading and upgrading refer to the Crestron Studio help file SIMPL Windows help file or the Crestron Toolbox help file Crestron Studio SIMPL Windows If a Crestron Studio or SIMPL Windows program is provided it can be uploaded to the control system using Crestron Studio or SIMPL Windows or Crestron Toolbox Firmware Check the Crestron Web site to find the latest firmware New us...
Page 25: ...ation on page 18 2 In Crestron Toolbox select Functions System Clock 3 Set the date and time Online Configuration The CP3 can be configured using the built in Web based setup tool 1 Using Internet Explorer navigate to http xxx xx xx xxx setup where xxx xx xx xxx is the IP address of the control system NOTE The Web based setup tool is only accessible from Internet Explorer NOTE If a security warnin...
Page 26: ...ys HDCP hostname IP address subnet mask default router domain and MAC address settings Click Advanced Settings to specify DNS servers Web server settings and SSL settings Click MyCrestron Dynamic DNS to configure the myCrestron com Dynamic DNS service Click Ethernet Diagnostics to test Ethernet communications Click Reboot to reboot the CP3 Application Setup Selects programs to be loaded on startup...
Page 27: ...w much power is needed for the system MSG LED illuminates Hardware or software failure Verify that hardware configuration matches software configuration Use Crestron Toolbox to display the error log Compilation error RLCMCVT166 RLCMCVT177 Poor analog versus serial signal definition in the SIMPL Windows program Confirm properly defined signal definition in the program System locks up Various Hold d...
Page 28: ...al conditions it lasts for approximately 10 years In the event that the clock fails only an authorized technician should replace it Refer to caution statement below CAUTION Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Check Network Wiring Us...
Page 29: ... chaining Cresnet units strip the ends of the wires carefully to avoid nicking the conductors Twist together the ends of the wires that share a pin on the network connector and tin the twisted connection Apply solder only to the ends of the twisted wires Avoid tinning too far up the wires or the end becomes brittle Insert the tinned connection into the Cresnet connector and tighten the retaining s...
Page 30: ...capabilities of the CP3 and CP3N additional information may be made available as manual updates These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision Check the Crestron Web site periodically for manual update availability and its relevance Updates are identified as an Addendum in the Download column ...
Page 31: ...es and incandescent lamps are not covered This warranty extends to products purchased directly from Crestron or an authorized Crestron dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any Crestron shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended...
Page 32: ...Crestron Electronics Inc Operations Guide DOC 7316C 15 Volvo Drive Rockleigh NJ 07647 2032696 Tel 888 CRESTRON 03 13 Fax 201 767 7576 Specifications subject to www crestron com change without notice ...