![Crestron CNXIO-16 Operation Manual Download Page 6](http://html.mh-extra.com/html/crestron/cnxio-16/cnxio-16_operation-manual_2683652006.webp)
CRESTRON
2
••
CNX Analog/Digital Input/Output Expansion Card: CNXIO-16
Operations Guide - DOC. 8125
Leading Specifications
The table below provides a summary of leading specifications for the CNXIO-16.
Dimensions and weight are approximations rounded to the nearest hundredth unit.
Leading Specifications of the CNXIO-16
DETAILS
Connectors
(2) 9-pin terminal block
Power Requirements
24VDC, network power; 2 Watts
Ratings:
Digital Output
250mA sync from maximum 24VDC
Digital Input
0-24VDC
Input Impedance
20K Ohm
Input Logic Threshold
1.25VDC
Analog Input
0-10VDC, protected to 24VDC maximum
SIMPL™ Windows®
Version 1.20.04 or later
CNX Operating System
Version 5.01.21X or later
CNX Monitor
Version 2.05X or later
Dimensions:
Height
0.98 in (2.49 cm)
Width
5.00 in (12.70 cm)
SPECIFICATIONS
As of the date of manufacture, the unit has been tested and found to comply with
specifications for CE marking.
Installation
Items required to install the CNXIO-16 are already attached to the unit. The only
tools required are a Phillips tip screwdriver and a grounding strap. Follow the
assembly procedure below.
CAUTION:
The CNXIO-16 contains electrostatic sensitive devices (ESD); observe
precautions for handling ESDs to avoid damaging the card.
NOTE:
If installing the CNXIO-16 into a CNMSX-AV, it is assumed that the
CNXCAGE has been installed.
1.
Disconnect power from the CNMSX.
2.
Use the Phillips tip screwdriver and remove two screws and blank
faceplate from the control system.
3.
Align the CNXIO-16 with the card guides in the open slot and slide
the expansion card into position.
4.
Firmly press both ends of the CNXIO-16 faceplate to seat the
expansion card into the control system connector.
5.
Tighten the thumb screws to secure the CNXIO-16 to the control
system.
6.
Reapply power to the CNMSX.