  1

CNX Control Processor Card:
CNXCPU

Description

Functional Description

The CNX Control Processor Card, CNXCPU,                    

CNXCPU Physical View

is the central processor unit of the CNX Modular
Control System. The CNXCPU performs the
execution of the SIMPL Windows program and
SIMPL+ programs as well as managing the
Cresnet network and the expansion cards
installed in the control system. The CNXCPU
requires an external power supply, CNPWS-75
(sold separately).

The CNXCPU features Crestron’s exclusive
DPA (Direct Processor Access) slot for
Ethernet/LAN expansion of the control network.
This slot provides high-speed access to the
processor, allowing high-bandwidth network
connections. The DPA permits 10BaseT and is
ready to support Firewire, ATM, 100BaseT and
other future protocols.

Physical Description

The CNXCPU, shown at the right, is a circuit
board fastened to an aluminum faceplate. The
faceplate contains one computer port, two
Cresnet connectors, and two LED indicators.
The circuit board (not shown) contains the DPA
slot that is used by the optional Ethernet
Expansion Card. The LAN/DPA port on the
faceplate is available when that card is installed.
The ports, connectors and indicators are
described on the next page.

24

Y

Z

G

C
R
E
S
N
E
T

C R E S T R O N

CNXCPU

CONTROL

PROCESSOR

PWR

NET

COMPUTER

LAN

DPA

5.00 in

(12.70 cm)

1.56 in

(3.96 cm)

Summary of Contents for CNXCPU

Page 1: ......

Page 2: ......

Page 3: ... CNXCPU 1 Description 1 Functional Description 1 Physical Description 1 Leading Specifications 4 Setup 4 Installation or Replacement 4 Hookup 5 Programming with SIMPLTM Windows 6 Problem Solving 6 Troubleshooting 6 Further Inquiries 6 Return and Warranty Policies 7 Merchandise Returns Repair Service 7 CRESTRON Limited Warranty 7 ...

Page 4: ......

Page 5: ...cessor Access slot for Ethernet LAN expansion of the control network This slot provides high speed access to the processor allowing high bandwidth network connections The DPA permits 10BaseT and is ready to support Firewire ATM 100BaseT and other future protocols Physical Description The CNXCPU shown at the right is a circuit board fastened to an aluminum faceplate The faceplate contains one compu...

Page 6: ...system and both ports are electrically connected The ports are modem compatible but the null modem cable is not included CRESNET Cresnet 4 Wire and 6 Pin Connectors 24 Y Z G C R E S N E T This 4 wire male connector typical Crestron network port labeled 24 Y Z G is used to provide 24VDC power via an external power supply that is sold separately Crestron recommends specific power supplies for its ne...

Page 7: ...ion Card Operations Installation Guide latest revision of Doc 8129 for further information LAN DPA Optional LAN DPA Port LAN DPA This 8 pin RJ type port is used to connect the control network to an Ethernet LAN It is part of the optional Ethernet Expansion Card CNXCPU Indicators The CNXCPU contains two LED indicators located on the faceplate The indicators are described below PWR This green LED il...

Page 8: ... of the remaining expansion cards Do not exceed 75 watts for total load factor As of the date of manufacture this unit has been tested and found to comply with specifications for CE marking NOTE This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference recei...

Page 9: ...seat the card into the control system connector 5 Tighten the thumb screws finger tight to secure the CNXCPU to the control system 6 Reapply power to the control system Hookup Refer to the example hookup diagram below and aside from applying power last complete the connections in any order Hookup Connections for CNXCPU TO SERIAL PORT ON PC PARALLEL DB9 CONNECTOR ALSO ON CONTROL SYSTEM FRONT PANEL ...

Page 10: ...to CNXCPU is are secure not illuminate SIMPL Windows program error Verify the SIMPL Windows program Hardware or software failure hardware incompatibility with software definitions or programming error Verify that hardware configuration matches software configuration i e card is in proper slot as defined by program Poll the network F4 via SIMPL Windows or VisionToolsTM Pro VT Pro Further Inquiries ...

Page 11: ...s from the date of shipment to purchaser Disk drives and any other moving or rotating mechanical parts are covered for a period of one 1 year CRESTRON warrants all its other products for a period of one year from the defects mentioned above excluding touchscreen display components which are covered for 90 days Incandescent lamps are completely excluded from Crestron s Limited Warranty CRESTRON sha...

Page 12: ......

Reviews: