An analog ramp is used to adjust the room volume. The symbol receives volume_up
and volume_down signals (
B
) from the touchpanel buttons. The level of the volume
is sent to the CNX-PAD8 (
E
). The ramp will adjust through the entire range of the
volume (0% to 100%) in 5-seconds.
Detail View of Volume Adjust Symbol (S-1) in SIMPL Windows’ Programming Manager
The next two symbols (S-4 and S-5) control the mute function of the CNX-PAD8.
While the room is receiving audio, pressing the MUTE button of the touchpanel (
C
)
clocks the toggle S-4 to output the room_1_mute signal from the high output. This
signal is sent to the CNX-PAD8 (
E
) to mute the audio. When in the “mute mode”,
pressing the touchpanel MUTE button again clocks the toggle to remove the mute
signal.
While in the “mute mode”, pressing any source or volume button of the touchpanel
(
A
) is also input to the OR symbol S-5. The output of this symbol resets toggle S-4
to remove the mute signal (
E
) from the CNX-PAD8.