CLW-SW1, SWS1, & SLVS1(W/A/B)
Wiring Diagram for CLW-SW1 (L) or CLW-SWS1 (R)
NOTE:
The WHITE (Neutral) connection on the
-SLVS1 is optional and is only required for operation of
the LED. If the neutral is not available, the white lead
should be capped off.
Cresnet
Hot
Neutral
Load
RED
BLACK
WHITE
BLUE
Ground
GREEN
LINE
120VAC
60Hz
60Hz
120VAC
LINE
GREEN
Ground
WHITE
BLACK
RED
Load
Neutral
Hot
Cresnet
5. Splice the gray wires of the -SW1 or -SWS1 to
the Class 2 low voltage wires connected to the
Crestron control system or a Crestron connection
block device. Push the wires and the splices into
a hole in the drywall to provide the necessary
separation.
6. Push all Class 1 Power wires back into the
wallbox and fasten the device to the wallbox
with the provided screws.
NOTE:
The RED (Load) and BLACK (Hot) wires are
#14 AWG. The BLUE (Slave) and WHITE (Neutral)
wires are #18 AWG. The GREEN (Ground) wire is #16
AWG. The GRAY (Cresnet) wires are #22 AWG. The
BLACK wire (Cresnet ground) paired with the GRAY
(Cresnet) wires is #22 AWG.
7. Attach decorative faceplate.
8. Restore
power.
Operating Button and Switch
The -SW1, -SWS1, and -SLVS1 feature one pushbutton.
The -SW1 and -SWS1 also have a three-position mode
selection switch. The function the pushbutton is
determined by the position of the mode selection switch.
Refer to the following diagram.
CLW-SWS1 with CLW-SLVS1 Wiring
NOTE:
The -SWS1 must be installed in the same
wallbox that contains the connections to the load.
Buttons of CLW-SW1, -SWS1, and -SLVS1
The following wiring diagram illustrates installation of
the -SWS1 with a -SLVS1.
Wiring Diagram of CLW-SWS1 with CLW-SLVS1
GREEN
LINE
120VAC
60Hz
WHITE
Ground
GREEN
BLACK
BLUE
CLW-SLVS1
Hot
Neutral
Load
RED
CLW-SWS1
BLACK
WHITE
CLW-SLVS1
BLUE
BLACK
BLUE
Ground
Ground
GREEN
WHITE
Cresnet
Button
Mode Selection Switch
(-SW1 & -SWS1 Only)
NOTE:
The -SLVS1 does not have a mode selection
switch. It will act in the same mode as the -SWS1.
NOTE:
Do not connect the BLUE (Slave) wire to the
BLACK (Hot) or RED (Load) wires.
OFF
When the mode selection switch is in the “OFF” position,
the pushbutton will not have any function and the load is
disconnected from the power source. This
must
be used
when changing light bulbs to ensure that the load is fully
disconnected from power.
NOTE:
The RED (Load) and BLACK (Hot) wires are
#14 AWG. The BLUE (Slave) and WHITE (Neutral)
wires are #18 AWG. The GREEN (Ground) wire is #16
AWG. The GRAY (Cresnet) wires are #22 AWG. The
BLACK wire (Cresnet ground) paired with the GRAY
(Cresnet) wires is #22 AWG.
NOTE:
If a -SWS1 is installed without a -SLVS1, the
BLUE lead (Slave) should be capped.
Installation Guide – DOC. 6251
Stand Alone Wall Box Switch: CLW-SW1, SWS1, & SLVS1
•
5