If the program is not running yet, loads can be tested by 
using Local Mode. Use Local Mode to verify that each 
load is connected to the proper output on the modules.  

If you cannot locate specific information or have 
questions after reviewing this guide, please take 
advantage of Crestron's award winning customer service 
team by calling the Crestron corporate headquarters at  
1-888-CRESTRON [1-888-273-7876]. For assistance in 
your local time zone, refer to the Crestron website 
(

www.crestron.com/offices

) for a listing of Crestron 

worldwide offices. 

1. Press 

the 

SETUP

 button momentarily (less than 

three seconds) to enter Local Mode. 
The 

SETUP

 LED and output LED 

1

 illuminate 

and power is applied to the loads connected to 
the 

DIM1 

output.  

2. Press 

the 

SETUP

 button again to turn off output 

1

 and turn on output 

2

.  

You can also log onto the online help section of the 
Crestron website (

www.crestron.com/onlinehelp

) to ask 

questions about Crestron products. First-time users will 
need to establish a user account to fully benefit from all 
available features.

 

3. Press 

the 

SETUP

 button again for each output. 

4.  After turning on the last output, press the 

SETUP

 button again to turn on all outputs. 

 

5. Press 

the 

SETUP

 button once more to turn off 

all outputs and LEDs and exit Local Mode. 

Industry Compliance 

As of the date of manufacture this device has been tested 
and found to comply with specifications for CE marking. 

 

Reference Documents 

The latest version of all documents mentioned within the 
guide can be obtained from the Crestron website 
(

http://www.crestron.com/manuals

). This link will 

provide a list of product manuals arranged in alphabetical 
order by model number.  

List of Related Reference Documents 

DOCUMENT TITLE 

CAEN Automation Enclosures 
CAENIB Automation Enclosures  
CAENIB-BP Blank Plate for CAENIB 
CLTIBN Circuit Breaker Terminal Block 

 

4  

  Terminal Block & Module:  CLTI- & CLXI-2DIM8 

Installation Guide – DOC. 6411A 

Summary of Contents for CLTI-

Page 1: ...DULE ROUNDING ERMINAL BLOCK TERMINAL BLOCK INSTALL INTO LOWEST AVAILABLE SPACES NOTE The two input lines must be the same phase or split phase NOTE When connecting to an Arc Fault Breaker the load should not exceed 1000 watts Terminal Block Module Locations Double wide Enclosure Installation The terminal block and module must be mounted into a Crestron Automation Enclosure by a licensed electricia...

Page 2: ...OUP 2 FEED DIM5 DIM8 FROM 16 AMP CIRCUIT BREAKER NEUTRAL AREA FOR MODULE LOCATION LABEL TO LOAD S LEFT SIDE WIRING LABEL TERMINAL BLOCK GND GROUNDING TERMINAL BLOCK NEUTRAL GROUP 1 FEED DIM1 DIM4 FROM 16 AMP CIRCUIT BREAKER LINE 1 LINE 2 3 Use the two supplied self tapping pan Phillips screws 8B x 6 mm length to secure the terminal block to the Crestron Automation Enclosure CAUTION Bypass jumpers ...

Page 3: ... is delivered to the loads 5 Turn off the circuit breakers and remove the bypass jumpers on the brown and red sections of the terminal block The jumpers on the blue sections of the terminal block must remain installed Refer to the figures in the next column for a close up of the jumpers NOTE Before the bypass jumpers are removed the Crestron Professional Automation Computer PAC2 which provides con...

Page 4: ...lso log onto the online help section of the Crestron website www crestron com onlinehelp to ask questions about Crestron products First time users will need to establish a user account to fully benefit from all available features 3 Press the SETUP button again for each output 4 After turning on the last output press the SETUP button again to turn on all outputs 5 Press the SETUP button once more t...

Page 5: ...r 90 days batteries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for whic...

Page 6: ...Terminal Block Module Crestron CLTI CLXI 2DIM8 6 Terminal Block Module CLTI CLXI 2DIM8 Installation Guide DOC 6411A This page is intentionally left blank ...

Reviews: