3.

 

Operating Instructions 

3.1

 

Introduction 

Before  operating,  user  is  required  to  perform  manual  check  on  items  as  listed 
below in sequence:  

 

Verify  that  the  plastic  cap  on  the  drain  nipple  of  the  tank  is  securely 
tight. Or, if the drain outlet is fitted with a valve, be sure that the valve is 
closed 

 

Fill the tank with the appropriate liquid to a depth sufficient to cover the 
parts being cleaned 

 

Check generator serial tag for proper power requirement 

 

3.2

 

Importance Safety Notification 

 

 

 

 

Be sure the receptacle provides proper electrical ground. 

 

 

 

Be certain generator location permits air passage through the 
cabinet. Rear of generator should be at least 6” from any wall 
or other obstruction. 

 

 

 

Generators  should  be  kept  dry  at  all  times.  Do  not  allow 
moisture  or  chemicals  to  collect  on  or  near  the  ultrasonic 
generators. 

 

Summary of Contents for Crest Ultrasonics Genesis

Page 1: ...Genesis Advanced Ceramics Technology M Sdn Bhd A Crest Group Inc Company No 1536 Jalan Perusahaan Kawasan Perusahaan Bukit Tengah 13600 Perai Penang Malaysia Tel 60 4 507 0018 Fax 60 4 507 0020 www c...

Page 2: ...TION 2 1 2 1 INTRODUCTION 2 1 2 2 POWER AND GROUNDING REQUIREMENT 2 2 2 3 POTENTIOMETERS 2 2 2 4 STANDARD CONTROLS 2 3 3 OPERATING INSTRUCTIONS 3 1 3 1 INTRODUCTION 3 1 3 2 IMPORTANCE SAFETY NOTIFICAT...

Page 3: ...number and voltage which may be found on a label at the rear of the generator chassis You should also refer to the circuit board part number with revision notation and serial number which are printed...

Page 4: ...efer to them whenever there is any question at all about the use of the cleaning liquids Adequate Ventilation Some cleaning liquids can be harmful or toxic to human life when used improperly Always av...

Page 5: ...arrying handle and an eight pin connector receptacle to which is attached the line cord At the front of the cabinet are two receptacles to receive the captive fasteners which hold the Plug In chassis...

Page 6: ...justment changes the peak amplitude of the power delivered to the load but it does not change the duty cycle as a power intensity control would It is particularly useful when power reduction is necess...

Page 7: ...Figure 2 4 Genesis Ultrasonic Generator rear view The features on the Genesis Ultrasonic Generators are as follows Item Feature On Off Switch With integral pilot light Located at the front panel of t...

Page 8: ...the generator was factory adjusted Degassing Modulation Selector Toggle Switch Located at the rear side of the Genesis Ultrasonic Generator The Hi position is a full wave modulation The Lo position is...

Page 9: ...be sure that the valve is closed Fill the tank with the appropriate liquid to a depth sufficient to cover the parts being cleaned Check generator serial tag for proper power requirement 3 2 Importanc...

Page 10: ...ap Instead move the one with the spade connection 3 Before operating check generator serial tag for proper power requirement 4 Plug the generator line cord into the appropriate outlet 5 Set the modula...

Page 11: ...el on off switch The red pilot light will turn off 3 3 2 Immersible Transducers and Generator Follow instruction below to operate immersible transducers and generator No Description 1 Refer to Immersi...

Page 12: ...of the hardware provided make the connection liquid tight 2 Mount or place the junction box so that liquid from the tank will not spill on the box If two mounting studs are present such as in Type DB...

Page 13: ...result in injury or death due to the presence of high voltages Item PM Activity Schedule Ultrasonic Cleaning ultrasonic generator M D daily W weekly M monthly Q quarterly HY half yearly Y yearly TBD...