background image

TIME

GAGE

DIVE TIME

          (MIN.)

MAX DEPTH

DEPTH

TEMP.

AVG

DEPTH

DIVE TIME

(SEC.)

MODE

DEPTH 

STOPWATCH

START / STOP

RESET

TIME

LONG PRESS FOR SWITCH 

DEPTH/AVG STOPWATCH

(Page 2)

AIR

DESAT TIME

COUNTDOWN

SURF TIME

DIVE

TIME

MAX 

DEPTH

NO FLY

TIME

COUNTDOWN

NITROX

DESAT TIME

COUNTDOWN

SURF TIME

DIVE

TIME

MAX 

DEPTH

NO FLY

TIME

COUNTDOWN

POST DIVE

SESSION TIME

FREE

DIVE TIME

          (MIN.)

MAX DEPTH

TEMP.

DIVE 

TIME

(SEC.)

DEPTH N° DIP

(Page 2)

11

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for CARTESIO

Page 1: ... THE COMPLETE CRESSI INSTRUCTION MANUAL at www cressi com manuals LONG LIFE BATTERY HIGH CONTRAST DISPLAY WIDE DIAMETER DISPLAY EASY ACCESS MULTI MODE MENU 35 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...mode long press Gas change in NITROX mode In surface or dive mode is available in SEL SEL ESC ESC MIX MIX SCROLL UP short press increase one step long press enter the function or confirm light top menu chrono mode dive mode OPERATING BUTTONS 2 Not avaible for GOA All manuals and user guides at all guides com ...

Page 3: ...2nd Time is ON 2nd TIME If the computer is in OFF lock mode The underwater diving funtcions are disabled STAGE INDICATOR OXYGEN DEEP STOP INDICATOR ASCENT ALARM SPEED OFF PPO2 VIOLATION ALTITUDE MODE DAILY ALARM BATTERY LOW SAFETY FACTOR INDICATOR OXYGEN TOXICITY BAR OFF MODE HIGH SPEED ASCENT 3 All manuals and user guides at all guides com ...

Page 4: ...e Time Alarm DIVE T 0 10 6 00 OFF Deep stop ON OFF Safety Factor SF 0 1 2 Altitude ALT 0 1 2 3 02 21 50 GAS 1 PPO2 1 2 1 6 GAS 1 02 21 99 GAS 2 PPO2 GAS 2 Deep stop ON OFF Safety Factor SF 0 1 2 Altitude ALT 0 1 2 3 PPO2 1 2 1 6 AIR MODE AIR MODE NITROX MODE NITROX MODE APNEA MODE APNEA MODE GAUGE MODE LOCK MODE Not avaible for GOA 4 Scroll the SET and confirm SEL Scroll and confirm SEL ESC TO RET...

Page 5: ...OUR SET MINUTE SET H 12 24 SET DAY SET MONTH SET YEAR SET HOUR SET MINUTE NO DECO TIME DEPTH INCREASE DEPTH DECREASE DEPTH SET 2nd TIME ON OFF Scroll 30 Min and confirm SEL see page 6 7 see page 9 Scroll the SET and confirm SEL Scroll and confirm SEL 5 ESC TO RETURN All manuals and user guides at all guides com ...

Page 6: ...NITS SEL TO CHANGE UNITS ESC TO RETURN ESC TO RETURN HISTORY HOURS IN USE COUNTER MAX DEPTH HISTORY CONNECT THE INTERFACE AND DOWNLOAD LATEST SOFTWARE UPDATES 6 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 7: ...ng this function the computerwillshowabarredspeakericonduring the entire dive If you decide to erase the tissue nitro gen saturation using the T ERASE function thecomputer willnotbeabletocalculateanysuc cessive dives in relation to nitrogen saturation In any event do not use this function if 48 hours have not passed since the last dive HIGH SPEED ASCENT ALARM SEL TO CHANGE ON OFF ALARM SPEED ESC T...

Page 8: ...ODE Page 1 Page 2 Page 2 Page 2 Page 2 Page 3 APNEA MODE SESSION TIME MAX DEPTH N DIP TEMP SURF TIME DIVE TIME Page 1 MAX DEPTH GAGE MODE DEPTH STOPWATCH DIVE TIME AVG DEPTH TEMP Page 1 Page 1 PPO2 O2 DIVE TIME SAFETY FACTOR NITROX MODE Not avaible for GOA 8 All manuals and user guides at all guides com ...

Page 9: ... DEPTH DIVE TIME SEC DEPTH DEPTH GAGE DIVE TIME MIN MAX DEPTH DIVE TIME SEC NITROX GAS INDICATOR PPO2 MAX DEPTH GAS 1 O2 GAS 1 PPO2 GAS 1 MAX1 Page 2 GAS INDICATOR PPO2 MAX DEPTH GAS 2 O2 GAS 2 PPO2 GAS 2 MAX Gas 1 2 Not avaible for GOA 9 All manuals and user guides at all guides com ...

Page 10: ...TH MAX MODE 02 PPO2 MAX PPO2 MAX DEPTH GAS SWITCH INDICATOR LONG PRESS FOR CHANGE GAS1 2 Page 2 Select the GAS and confirm NITROX GAS SWITCH SEL Not avaible for GOA 10 NO DECO TIME TOTAL ASCENT TIME TEMP DEPTH NITROX Page 2 DIVE TIME MIN MAX DEPTH MODE TIME 02 MIX All manuals and user guides at all guides com ...

Page 11: ... AVG STOPWATCH Page 2 AIR DESAT TIME COUNTDOWN SURF TIME DIVE TIME MAX DEPTH NO FLY TIME COUNTDOWN NITROX DESAT TIME COUNTDOWN SURF TIME DIVE TIME MAX DEPTH NO FLY TIME COUNTDOWN POST DIVE SESSION TIME FREE DIVE TIME MIN MAX DEPTH TEMP DIVE TIME SEC DEPTH N DIP Page 2 11 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 12: ... 39 010 830 79 220 info cressi sub it www cressi com BATTERY SURFACE ESC TO END THE SESSION SURFACE Scroll YES NO and confirm SEL FREE DIVE TIME LAST DIP MAX DEPTH LAST DIP TEMP SURFACE TIME TOTAL DIP Page 2 LOW BATTERY YOU SHOULD CHANGE THE BATTERY SOON YOU MUST CHANGE THE BATTERY DIVE FUNCTION IS DISABLED All manuals and user guides at all guides com ...

Reviews: