OPERATING and MAINTENANCE INSTRUCTIONS
for CCB-96A and CCB-120A Banquet Warming Cabinets
TROUBLE-SHOOTING CHART:
FAILURE
POSSIBLE CAUSE
1. Yellow light at switch does NOT light.
1a. Circuit breaker/fuse to wall outlet blown.
2a. Cord is unplugged from wall outlet.
3a. Switch is “OFF.”
2. Unit does not get hot.
2a. Thermostat set too low or are off.
2b. Switch is “OFF.”
3. Unit gets too hot or won’t shut off
3a. Defective electrical parts.
3b. UNPLUG UNIT FROM WALL OUTLET
4. Blower does not work or makes noise.
4a. Defective Blower
5. Excess moisture in cabinet.
5a. Foods taken from oven or fryer should be “slacked
out” for 5 minutes before placing in hot cabinet.
NOTE:
Optional digital thermometer will fl ash if cabinet temperature is below 140°F or above 250°F.
Call the Factory if you need different settings.
If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400.
REPLACEMENT PARTS:
CABINET PARTS:
DESCRIPTION
120 VOLT
240 VOLT
DESCRIPTION
PART NO.
Hot Unit
HU18671-184*
HU18671-185
Door Latch Kit
1006-143-K
Terminal Block
0852-091
0852-091
Latch Strike
1006-144-K
Blower Kit
0769-180-K
0769-182-K
Door Gasket, CCB-96A
0861-173
Heater Kit
0811-214-01
0811-215-01
Door Gasket, CCB-120A
0861-172
Thermostat Kit
0848-062-K
0848-062-K
Door Hinge
0519-084
Thermometer Kit
5238-030-K
5238-030-K
Push Handle
1072-089
Power Cord
0810-029-02*
0810-039-03
Wire Grid
1170-095
Switch Kit
0808-118-K
0808-118-K
Door Assembly, CCB-96A
1221-460-K
Door Assembly, CCB-120A 1221-461-K
For Canadian Use:*
Hot Unit (120 Volt)
HU18671-184C
Power Cord Plug
0713-017
Thermometer Kit, °C
5238-024-01