D I A M A N T
Pro
39
Original instructions.
USER PROGRAMMING
Group overuse
Use the following steps to program the group overuse settings:
1. Press the Group Overuse
button to enter the
programming menu.
℃
℃
℃
℃
Alarms settings:
CLEAN OVERDUE TRIGGER:
Trigger to release the “CLEAN OVERDUE WARNING”, in which
the machine notifies the user that there hasn’t been a proper group
cleaning in “x group” in the last 4 to 72h (depends on the parameter
specified). Referred to “group cleaning” NOT the SmartSteam.
GROUP OVER USE TRIGGER:
Trigger of the “GROUP OVER USE “ alarm in which when it reaches
the parameter “MIN COFFEES GR.OVER USE” then it adds all total
counters for all groups. If one of the groups is used 1 to 3 times the
total counter, then “GROUP OVER USE” alarm is triggered.
MIN COFFEE GROUP MINIMUM:
Minimum number of coffees to define the group overuse (500)
Group cleaning
Important:
When using this function to perform the weekly cleaning with espresso machine detergent no
water will flow from the group when the portafilter with blind filter is installed, however hot water
will still flow from the other groups, so the cleaning with detergent must be repeated separately
for each group. It is important to perform two or three more clearings without detergent
afterward for each group to ensure all detergent has been flushed out of the group.
WARNING!
THE CLEANING WATER IS VERY HOT! DO NOT PLACE FINGERS OR HANDS UNDER THE
GROUP, OPEN THE GROUP OR REMOVE THE PORTAFILTER UNTIL THE CLEANING CYCLE
HAS FINISHED TO AVOID SCALDING OR BURNS! WAIT 3-4 SECONDS AFTER DISPENSING
HAS FINISHED BEFORE REMOVING THE PORTAFILTER TO ALLOW PRESSURE TO RELEASE.
Pro Tip:
Optionally, as a time saving
step,weekly cleaning with
detergent can be done on
all groups simultaneously
if extra blind filters are
purchased for use with
the extra groups. Ask
your distributor about
purchasing extra blind
filters if desired.
Use the following steps to activate the automatic group cleaning cycle for the brewing groups:
1. Press the Group Cleaning
button to enter the
programming menu.
2. Select the group to be cleaned,
or select the brush button to
clean all groups simultaneously.
Use the
X
to exit.
Note:
Automatic group cleaning with detergent takes approximately four minutes.
i
℃
℃
℃
℃
AUTO
℃
℃
℃
℃
2
3
1
AUTO
AUTO
AUTO