CI380X01R5

ANGLE ADJUSTMENT 

STEP 1:

After the luminaire is installed, the angle of the 
luminaire can be adjusted approximately 90° up or 
down in 5° increments. 

STEP 2: 

To adjust the angle, loosen the four 3/8 – 16 X 1.5" 
Socket Head Cap Screws located in the top section 
of the Mounting Clamp using the provided 5/16” Hex 
Wrench.

STEP 3: 

Using the Angle Bracket, shown in 

Figure 3, 

as a 

guide rotate the luminaire to the desired position and 
retighten the screws loosened in Step 2 to 120 in.-lbs. 

LATERAL ADJUSTMENT

STEP 1:

The position of the luminaire can also be adjusted 
laterally. To adjust the Lateral position, loosen the four  
3/8 – 16 X 1.5" Socket Head Cap Screws located in the 
top section of the Mounting Clamp using the provided 
5/16" Hex Wrench. See 

Figure 3.

STEP 2: 

Remove the Angle Bracket and (2) screws and set aside. 
See 

Figure 3

 

STEP 3: 

The Angle Bracket can be secured using the existing 
holes on the luminaire bar. Set the Mounting Clamp to 
desired lateral adjustment using the following positions 
on the bar (See 

Figure 4)

•  Position 2  - Left justification.
•  Position 4  - Center position (when angle 

bracket is on the left side of the mounting 
clamp).

•  Position 5  -  Center position (when angle 

bracket is on the right side of the mounting 
clamp).

•  Position 7  - Right justification.

NOTE:

 Positions 1,3,6 and 8 will not be able to be used.

NOTE:

 Mounting two luminaires to a 24” Bullhorn 

Tenon will require one luminaire mounted in position 2 
and one luminaire mounted in position 7.

STEP 4:

Once desired position is achieved reinstall the Angle 
Bracket using (2) screws that were removed in Step 2. 

STEP 5:

Retighten screws that were loosened in Step 1 to 120 
in-lbs.

NEMA

® 

 RECEPTACLE (OPTIONAL) 

STEP 1: 

DO NOT loosen/tighten pan head screws for the NEMA

® 

 

receptacle.

STEP 2: 

Rotational adjustment of the photo control is tool-less.

STEP 3: 

Engage/install photo control into NEMA

® 

 receptacle on 

top of the fixture.

STEP 4: 

Firmly rotate photo-control with its photo-eye 
approximately in the ‘N’ north direction. Some photo-
controls operate best somewhere between NW and NE.

3

Mounting 

Clamp

Angle 

Bracket

Angle Markings

Socket Head 

Cap Screws

Numbers on angle bracket are shown for illustration purpose 

only. Actual bracket doesn’t show numbers.

4

4

3

2

1

8

7

6

5

Angle Bracket is Shown in Position 5 in This Illustration

Mounting Clamp