ELECTRICAL CONNECTIONS
STEP 1:
Using Listed 90°C minimum rated wire connectors make the following
electrical connections within the adjustable fitter wiring compartment:
a. For 208/277V connect the black fixture lead to the voltage supply
or Hot 1 (for 240/347/480V wiring).
b. For 208/277V connect the white fixture lead to the neutral supply
or Hot 2 (for 240/347/480V wiring).
c. Connect the green or green/yellow ground lead to ground.
d. For Dimming connect the violet dimming positive lead to the
supply dimming positive lead. If dimming is not going to be used
cap of the violet lead.
e. For Dimming connect the grey dimming
negative lead
to the
supply dimming negative lead. If dimming is not going to be used
cap of the grey lead.
f. Connect orange fixture lead to orange supply lead.
g. Connect brown fixture lead to brown supply lead.
LINE
OR HOT 1
GREEN
LINE-BLACK
GROUND-GREEN
NEUTRAL-WHITE
GREY
VIOLET
NEUTRAL
OR HOT 2
VIOLET
GREY
SUPPL
Y WIRING
(DIMMING OPTIONAL)
LUMINAIRE
BROWN
ORANGE
BROWN
(C
ONTROLS FROM
PHO
TOC
ONTROL
OPTIONAL)
ORANGE
DRV
DRV
CRTL
1 2 3 4 5
9 1 2
3
4
5
6
7
8
5
6
Luminaire Cover
Door
NEMA
®
RECEPTACLE (OPTIONAL)
STEP 1:
Rotational adjustment of the photocontrol
receptacle is tool-less . DO NOT loosen/
tighten the screws securing the receptacle to
the housing.
STEP 2:
Engage/install photocontrol into photocontrol
receptacle on to of luminaire.
STEP 3:
If necessary, rotate photo-control so its
photo-eye is aimed in the north direction.
Some photo-controls operate best
somewhere between north-west and north-
east.
FIELD ADJUSTABLE DIMMING -
(OPTIONAL)
NOTE: This luminaire may be provided with
field adjustable dimming. If so, luminaires
leave the factory adjusted to the maximum
setting specified when ordered. Visit
www.cree.com/Lighting/Document-Library
for product dimming spec sheet.
STEP 1:
The Dimming module (see
Figure 5) is
located inside the luminaire. Open the
luminaire door cover by loosening the (7)
screws. See
Figure 6.
STEP 2:
Establish the desired input power multiplier
by referring to the product dimming spec
sheet and adjust the setting on the Dimming
Module to the desired position.
STEP 3:
Replace the Luminaire Door Cover that was
removed in Step 1. Torque screws to 23 in-lbs
[2.6 N•m]. Ensure that the Luminaire Door
Cover Seal does not get disturbed during this