ELECTRICAL CONNECTIONS

STEP 1:

Using Listed 90°C minimum rated wire connectors make the following 
electrical connections within the adjustable fitter wiring compartment:

a.  For 208/277V connect the black fixture lead to the voltage supply 

or Hot 1 (for 240/347/480V wiring).

b.  For 208/277V connect the white fixture lead to the neutral supply 

or Hot 2 (for 240/347/480V wiring).

c.  Connect the green or green/yellow ground lead to ground.
d.  For Dimming connect the violet dimming positive lead to the 

supply dimming positive lead. If dimming is not going to be used 
cap of the violet lead.

e.  For Dimming connect the grey dimming 

negative lead 

to the 

supply dimming negative lead. If dimming is not going to be used 
cap of the grey lead.

f.  Connect orange fixture lead to orange supply lead.
g.  Connect brown fixture lead to brown supply lead.

   LINE

OR HOT 1

GREEN

LINE-BLACK

GROUND-GREEN

NEUTRAL-WHITE

GREY

VIOLET

NEUTRAL

OR HOT 2

VIOLET

GREY

SUPPL

Y WIRING

(DIMMING OPTIONAL)

LUMINAIRE

BROWN

ORANGE

BROWN

(C

ONTROLS FROM

PHO

TOC
ONTROL

 OPTIONAL)

ORANGE

DRV

DRV

CRTL

1   2   3  4   5 

9 1 2

3

4

5

6

7

8

5

6

Luminaire Cover 

Door

NEMA

® 

 RECEPTACLE (OPTIONAL) 

STEP 1: 

Rotational adjustment of the photocontrol 
receptacle is tool-less . DO NOT loosen/
tighten the screws securing the receptacle to 
the housing.

STEP 2: 

Engage/install photocontrol into photocontrol 
receptacle on to of luminaire.

STEP 3: 

If necessary, rotate photo-control so its 
photo-eye is aimed in the north direction. 
Some photo-controls operate best 

somewhere between north-west and north-
east.

FIELD ADJUSTABLE DIMMING - 

(OPTIONAL)

NOTE: This luminaire may be provided with 
field adjustable dimming. If so, luminaires 
leave the factory adjusted to the maximum 
setting specified when ordered. Visit 
www.cree.com/Lighting/Document-Library 
for product dimming spec sheet. 

STEP 1:

The Dimming module (see 

Figure 5) is 

located inside the luminaire. Open the 
luminaire door cover by loosening the (7) 
screws. See 

Figure 6.

STEP 2:

Establish the desired input power multiplier 
by referring to the product dimming spec 
sheet and adjust the setting on the Dimming 
Module to the desired position.

STEP 3:

Replace the Luminaire Door Cover that was 
removed in Step 1. Torque screws to 23 in-lbs 
[2.6 N•m]. Ensure that the Luminaire Door 
Cover Seal does not get disturbed during this 
process.

Reviews: