background image

2 of 3

LPN00355X0001A1_A

20°

45°

60°

90°

180°

STEP 9:

Make wire connections in Adjustable Fitter Wiring 
Compartment per Electrical Connections section on 
the back page. Cut leads from the luminaire power 
supply cord and re-strip as necessary.

STEP 10:

Replace the Wiring Compartment Cover that 

was removed in Step 1 and secure with (3) self-

retaining screws. Torque screws to 23 in-lbs 

[2.6 N•m]. Ensure that the o-ring does not get 

pinched. See 

F

igure 1.

 

FIXTURE AIMING

STEP 1:

Remove the Wiring Compartment Cover from the 
Adjustable Fitter, if necessary, and set cover aside to 
reinstall later. See 

Figure 1.

STEP 2:

Loosen 7/16” hex bolt in Adjustable Fitter Wiring 
Compartment until Adjustable Fitter can be 
articulated. It is not necessary to remove this 
fastener.

STEP 3:

Adjust the luminaire to the desired aiming angle. 
The luminaire may be aimed in 5° increments. 
Markings are located on the exterior of the 
Adjustable Fitter for ease of aiming. See 

Figure 4.

STEP 4:

Upon completion of aiming, torque the 7/16" hex 
bolt to 360 in-lbs [41 N•m] and verify that the teeth 
are properly aligned and fully engaged. See  
Figure 3.

STEP 5:

Replace the Wiring Compartment Cover that was 
removed in Step 1 and secure with (3) self-retaining 
screws. Torque screws to 23 in-lbs [2.6 N•m]. 
Ensure that the o-ring does not get pinched. See 
Figure 1.

15°

45°

45°

45°

45°

1/2" and 2" (51mm) Adjustable Fitter Positions

4

Major Divisions: 45°
Minor Divisions: 15°

3