OSQ HO Series
LED Area Light
Adjustable Arm Mount
1 of 3
LPN00355X0001A1_A
INSTALLATION INSTRUCTIONS
INSTRUCTIONS D’INSTALLATION
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be
followed including the following:
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
1. DANGER
- Risk of shock- Disconnect power before installation.
DANGER
– Risque de choc – Couper l’alimentation avant l’installation.
2. This luminaire must be installed in accordance with the NEC or your local
electrical code. If you are not familiar with these codes and requirements,
consult a qualified electrician.
Ce produit doit être installé conformément à NEC ou votre code électrique
local. Si vous n’êtes pas familier avec ces codes et ces exigences, veuillez
contacter un électricien qualifié.
SAVE THESE INSTRUCTIONS FOR FUTURE
REFERENCE
ADJUSTABLE ARM MOUNT
INSTALLATION
STEP 1:
Remove the wiring compartment cover from
the adjustable fitter and set cover aside to
reinstall later.
See
Figure 1.
STEP 2:
Route the luminaire power supply cord
through the Adjustable Fitter, luminaire
side and engage the adjustable fitter onto
the luminaire using (4) 3/8” hex bolts on the
top and bottom of the luminaire. Torque hex
bolts to 360 in-lbs (41 N•m).
STEP 3:
Place the provided O-ring into the retaining
groove on the Adjustable Fitter Luminaire Side.
Route luminaire power supply wires into wiring
compartment on Adjustable Fitter Pole Side
using 1 of 2 available access holes as shown
in
Figure 2. Hole selection is dependent on
desired aiming angle. Use hole A for 0-90° and
hole B for 90-180° aiming, respectively. See
Figures 1 and 2.
STEP 4:
Join the luminaire and pole side adjustable
fitter components using the 7/16” hex bolt.
The 7/16” hex bolt should be started by hand
to ensure proper thread alignment. Prior to
applying full torque to hex bolt, ensure that
the teeth of the two mating components are
properly aligned. See Figures 1 and 3. Take
care to ensure the O-ring is not dislodged
during this process. The Fixture aiming
procedure may be performed at this point. See
Fixture Aiming section of this document. Upon
completion of aiming, torque 7/16” hex bolt to
360 in-lbs (41 N•m) and verify that the teeth
are properly aligned and fully engaged. See
Figure 3 on the next page.
STEP 5:
Install and tighten the 5/16” setscrews on
the side of the Luminaire Housing. Torque
setscrews to 120 in-lbs [14 N•m]. See Figure 1.
STEP 6:
Route the pole’s supply leads up through the
adjustable fitter and into the adjustable fitter
wiring compartment. See
Figure 1.
STEP 7:
Slip the Adjustable Fitter onto the tenon.
Securely tighten (4) 3/8”Allen head
setscrews. Ensure that the tenon remains
centered inside the fitter by alternating
between the setscrews. Torque setscrews to
180 in-lbs [20 N•m]. See
Figure 1.
STEP 8:
Strain relief is required for electrical
connections on the adjustable fitter mount for
mount heights of 25’ (7.6 m) and higher. Tie a
knot in the supply wires above the hole in the
adjustable fitter wiring compartment to reduce
the strain on the connections. Ensure that
the knot will not slip through the hole in the
Adjustable Fitter Wiring Compartment.
TO INSTALL:
1
Wiring
Compartment
O-Ring
Wiring
Compartment
Cover
Allen Head Set
Screws
Adjustable Fitter
Luminaire Side
(4) 3/8" Bolts
Tools Required:
• #2 Philips screwdriver
• 5/8" socket
• 9/16" socket
• 3/16" hex drive
• 5/32" hex drive
• Wire cutter, if necessary
• Wire stripper, if
necessary
• T20 torx drive (for Field
Adjustable Dimming, if
necessary)
• 3” Socket Extension
• #2 Phillips Bit
• T20 Bit
Adjustable Fitter
Pole Side
7/16" Bolt
A
B
2