3 of 4
LPN00611X0001A1_C
4
Test Switch
Large Trim Ring
Small Trim Ring
Ceiling
5
RF Module
Access Hole, Reset
Button Inside
Blue LED
Placement
RESET RF MODULE
NOTE:
The Blue LED is located behind the CREE logo on the RF
Module. The CREE logo with illuminate blue when the Blue LED
is active.
STEP 1:
Actuate RESET button through the access hole. Push and hold
until LED on RF module begins blinking rapidly (approximately
6-7 seconds). See
Figure 5.
STEP 2:
Release for 1 sec.
STEP 3:
Press/Hold RESET button for 0.5 sec. Light will turn off for a
few seconds then go to full bright and the Blue LED on the RF
Module should begin a 2 blink sequence.
Figure 4.
INSTALLING TEST SWITCH
STEP 1:
Install test switch assembly into ceiling by drilling a 1” hole into
the ceiling.
STEP 2:
Unscrew the small trim ring and place test switch assembly
through the ceiling. See
Figure 5
.
STEP 3:
Secure the test switch assembly by screwing the small trim ring
removed in Step 5 back onto the test switch assembly. Tighten
the larger trim ring above the ceiling until it is snugged tight
against the ceiling. See
Figure 5
.
CLEANING LENS
STEP 1:
Remove lens and end cap assembly by pulling straight
downward gently. See
Figure 6.
STEP 3:
After cleaning is complete insert lens and end cap assembly
back into the luminaire housing. Check end caps for any visible
gap between the end cap and end panel. If necessary push end
cap against the end panel to eliminate gaps. Check lens for any
visible gap between the lens and luminaire.
TROUBLESHOOTING:
Out of the box, if the light does not turn on when power is
applied:
• Check Wiring with power off
• If wired correctly, check to see if Blue LED blinking on
the RF Module.
• If Blue LED is blinking, then perform a RESET
(See RESET RF MODULE section).
• If Blue LED is on solid or off, call Cree Customer Service.
• If you have done a RESET, and the light is still off, call
Cree Customer Service.
If light is unresponsive, use Cree Configuration Tool to verify
configuration.
6
Lens