background image

 Page 2 of 2

The information in this document in subject to change without notice. 
Visit website for patents that cover these products: Patent http://www.cree.com/patents

 

 

     Visit website for warranties that cover Cree® BetaLED® Technology products:  

 

 

     Warranties http://www.cree.com/lighting/products/warranty

1. 

Using the supplied wiring harness, connect the supply wire to 
the supply harness wires using the provided wire connectors.  

 

NOTE

: The ground wires that are attached to the Electrical 

Connections Compartment Cover and to the inside of the 

mounting arm need to be connected to the Supply Ground 
wire using the provided wire connector.  

2.  If luminaire has 0-10V Dimming Option, connect the Violet Dim 

(+) and Gray Dim (-) leads.

3.  Connect the fixture and supply harnesses. See 

Figure 4

.

1. 

Using the supplied wiring harness, connect the supply wire to 
the supply harness wires using the provided wire connectors.  
 

NOTE

: The ground wires that are attached to the Electrical 

Connections Compartment Cover and to the inside of the 
mounting arm need to be connected to the Supply Ground 
wire using the provided wire connector.  

2.  Connect the fixture and supply harnesses. See 

Figure 5

.

1. 

Using the supplied wiring harness, connect the supply wire to 
the supply harness wires using the provided wire connectors.  

 
NOTE: The ground wires that are attached to the Electrical 

Connections Compartment Cover and to the inside of the 
mounting arm need to be connected to the Supply Ground 
wire using the provided wire connector. 

2.  See 

Figure 6

.

3.  Connect the supply side connector to the fixture wiring 

connector.

 

 
 

 

STANDARD ELECTRICAL CONNECTIONS - 
PHASE TO PHASE 208, 240V

LUTRON ELECTRICAL CONNECTIONS – 
ECOSYSTEM DIGITAL DIMMING

Figure 4

Figure 5

UTRON ELECTRICAL CONNECTIONS – 
3-WIRE DIMMING

Figure 6

   

   

   

Reviews: