HOOK AND CORD MOUNT

STEP 1:

Push down on retainer spring until top of spring 
is free of luminaire hook. See 

Figure 2.

STEP 2:

Slide hook into securely mounted  customer 
supplied eye hanger and return retainer spring to 
original position.

Note: 

The luminaire should already be factory set 

for correct balance. However, should you need 
to, the fixture may be balanced by loosening 
the hook adjustment set screw on the top of the 
housing and sliding the hook as necessary for 
correct balance. Tighten hook set screw when 
finished. See 

Figure 2.

REFLECTOR INSTALLATION

STEP 1:

Loosen the (4) screws, shown in 

Figure 3

, at least 

0.1 inch from the heatsink. 

NOTE:

 The view in Figure 7 is off the underside of 

the luminaire.

STEP 2:

Bring trim into housing and line up the (4) 
screws from Step 1, with the keyhole slots on the 
reflector. See 

Figure 4.

STEP 3:

Rotate trim, turn clockwise and tighten the (4) 
screws from Step 1. See 

Figure 4

.

ELECTRICAL CONNECTIONS

STEP 1:

Make the following Electrical Connections :

a.  Connect the black fixture lead to the voltage supply 

position of the terminal block.

b.  Connect the white fixture lead to the neutral supply 

position of the terminal block.

c.  Connect the green or green/yellow ground lead to the 

green wire position of the terminal block.

   LINE

GREEN

LINE-BLACK

GROUND-GREEN

NEUTRAL-WHITE