Creda Spa100 Installation And User Manual Download Page 6

 

 

HOW TO MAINTAIN YOUR 

SPA100 

 SHOWER 

5.

 

Re-Fit the front cover (see Diagram 5) and replace the top and bottom fastening screws. 
a.

 

Ensure outer knob “A” is aligned fully anti-clockwise to the “   (stop)“ position. 

b.

 

Ensure inner knob “B” is aligned to the “  (high)” position.   

c.

 

In the main body of the shower, turn the “Drive Spider” fully anti-clockwise until it stops. 

d.

 

In the main body of the shower, turn the “Drive Gite” anti-clockwise until it is at “12 o’clock”. 

e.

 

Fit the front cover of the shower to the main body ensuring that the 3 x “Drive Spider Legs” 

engage with the slots in outer knob “A”. 

f.

 

Check that outer knob “A” has been correctly aligned by ensuring that all 3 power settings can 

be selected, and returns to the “  (stop)“ position.  

g.

 

Check that inner knob “B” has been correctly aligned by turning clockwise and ensuring that 
knob turns approximately 3/4 of a turn (270°) and when turned back fully anti-clockwise, 

returns to the “  (high)” position. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

6.

 

Fit the shower hose, and operate the shower first without the handset to flush out particles,                    

fit the handset and then operate the shower as on page 7 or 12 and check: 

a.

 

That the water gets to a satisfactory temperature. 

b.

 

Water flow can be adjusted by inner control knob “B”. 

c.

 

Power selection operates in all 3 positions, giving a change in water temperature and 

that the neon light functions correctly. 

d.

 

Check again for leaks and that the holes in the shower handset are not blocked 

 

8.

 

DEMONSTRATE OPERATION TO USERS 

 

 

It is recommended that the shower unit and hose etc. be cleaned using a soft cloth and that the use 

of abrasive or solvent based cleaning fluid be avoided, especially on any plated finishes.  

We recommend that before any cleaning, the isolating switch be turned off, thus avoiding 

accidentally switching on the shower.

 

 

WARNING: YOU MUST REGULARLY INSPECT THE SHOWER HOSE FOR WEAR AND DAMAGE.                                                    
                    REPLACE IF NECESSARY, OR EVERY TWO YEARS, WITH A CREDA APPROVED PART. 

 

WARNING: IN ORDER TO MAINTAIN THE PERFORMANCE OF YOUR SHOWER, 

YOU MUST CLEAN THE SHOWER HANDSET REGULARLY.

 

 

All water contains particles of lime, which build up in the shower handset and unit reducing the 
performance. It is therefore important to clean the shower handset by simply rubbing the rubber 

nozzles

or soaking in a proprietary lime-scale remover and rinsing thoroughly before use.

  

 

NOTE:

  After use it is normal for some water to drip from the shower handset for a few moments.  

            This inhibits scale build-up over prolonged use. 

 

IF WATER IS TOO COLD 

 

Turn inner knob “B”

 

clockwise

 in the 

direction of the “red arrows” to “1 o’clock” 

and continue turning clockwise until you get 
the water temperature of your liking.  

 

Wait 20 seconds

 after each adjustment 

for the water temperature to stablise. 

 

IF WATER IS TOO HOT 

 

Turn

 

inner

 

knob “B” anti-clockwise

 in the 

direction of the “blue arrows” to “11 o’clock” 

and continue turning anti-clockwise until you 
get the water temperature of your liking.                                                                          

 

Wait 20 seconds

 after each adjustment for 

the water temperature to stabilise.  

      

If after turning fully anti-clockwise, water is 

still too hot, adjust outer knob “A” to          
“  (medium)” setting and re-adjust as above. 

 

Water flow will be reduced on this setting. 

 

 

 

1.

 

Ensure the electricity and water are turned on to the unit. 

 

2.

 

Your shower has 3 power settings selected by turning outer                                                                        
knob “A” (see Diagram 6). 
The most popular is “

 (high)”.  

There are also options for a “

 (medium)”                                                                                             

or “

 (cold)” shower (see notes 8 and 9). 

 

For this example turn outer knob “A” to “ 

 (high) ”                                                                                

and set inner knob “B”  to “12 o’clock”. 

 

3.

 

The water will flow and the neon light will glow brightly.  

 

4.

 

Allow about 20 seconds

 for the temperature of the water                                                                             

to stabilise. It is recommended that you do not wholly enter                                                                           

the water spray during this period, even if the shower has just been used. 

 

   

 

5. 

Once a temperature setting to your liking 
has been achieved, inner knob “B” will rarely 

need adjusting. You must however take into 

account required adjustments for variations 
of incoming mains water temperature between summer and winter (see “Effect of Seasonal 

Incoming Water Temperature Changes” page 10).

 

 

6.

 

When you have 

finished

 showering, turn outer knob “A” anti-clockwise to the “  (stop)” 

position. 

Water will continue to flow for up to 3 seconds before switching off.

                              

This reduces the temperature of the water in the tank for the next user.                                                                      

Switch off the electricity at the ceiling switch or local isolator. 

 

7.

 

The “  (medium)” setting of outer knob “A” reduces the power used by the shower giving a 

cooler shower or the option of reduced water flow. This option is mainly used for summer usage 

and if this is used then inner knob “B” must be re-adjusted. 

 

8.

 

The “  (cold)” setting of outer knob “A” will supply water without any heating, and the neon 

light will go out. 

 

9.

 

Your shower is 

designed to stabilise temperature

 changes caused by water pressure 

fluctuations (see “Effect of Other Water Devices on Incoming Water Supply” page 10).  

 

10.

 

Note that inner knob “B” 

IS NOT A TAP

 and does not turn the water off. 

 

WARNING: DO NOT SWITCH THE SHOWER ON IF YOU SUSPECT IT OF BEING FROZEN.  

WAIT UNTIL YOU ARE SURE IT HAS THAWED OUT.

 

 

WARNING: DO NOT OPERATE THE SHOWER IF WATER IS DISCHARGED FROM THE PRESSURE 

RELIEF VALVE. MAINTENANCE IS REQUIRED BEFORE THE SHOWER CAN BE USED. 

 

WARNING: CONSIDERATION SHOULD BE GIVEN TO SUPERVISING THE YOUNG, ELDERLY AND 

THE INFIRM WHILST THEY USE THIS SHOWER. 

HOW TO USE YOUR SPA100 

 SHOWER (DETAILED) 

Reviews: