4.4.5   Stacker Status Response Datasheet 

      The following table shows stacker status response datasheet.   

Status 

Code 

Specification 

Full  of  cards  in 
stacker 

‘0’ (0x30) 

There are enough cards in stacker 

Lack  of  card  in 
stacker 

‘1’(0x31) 

Card  is  not  sufficient,  please 
replenish cards 

No card in stacker 

‘2’(0x32) 

There is no card in stacker 

Note:    Data in parentheses is the hex value of matched ASCII. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for CRT-541

Page 1: ...spenser Machine Ver 1 0 PRODUCT SPECIFICATION CREATOR CHINA TECH CO LTD 2F M 10 Building Center Area Hi tech Industrial Park Shenzhen Guangdong China TEL 86 755 26710691 FAX 86 755 26710105 Http www china creator com ...

Page 2: ...ATA PACKAGE STRUCTURE 7 4 4 2 1 FROM HOST TO UNIT 7 4 4 2 2 FROM UNIT TO HOST 7 4 4 3 COMMAND LIST 8 4 4 4 WORKING STATUS RESPONSE DATASHEET 8 4 4 5 STACKER STATUS RESPONSE DATASHEET 9 5 GENERAL COMMUNICATION PROCESS 10 5 1 TYPICAL COMMUNICATION PROCESS BETWEEN HOST UNIT 11 5 1 1 NORMAL PROCESS OF DISPENDING 11 5 1 2 RECEIVED DISPENSING COMMAND 11 5 1 3 RECEIVED DISPENSING COMMAND WHILE DISPENSER ...

Page 3: ...3 Revision Log Version Revision Time Content 1 0 2010 1 25 First Release ...

Page 4: ...l aspects including communication protocol mounting holes position and so on In addition CRT 541 has the following features Prevent 2 cards dispensing Paper card dispensing design Easy adjustment of card thickness Easy card loading maintenance Support ISP download on line Support multi units communication Card stacker empty and pre empty detection Pre Card dispensing function Iron Block available ...

Page 5: ...nal stackers Extra long stacker 285PCS CRT 500 TCZ 285pcs 0 76 standar card Long stacker 170PCS CRT 500 CKZ 170pcs 0 76 standar card Short stacker 60PCS CRT 500 DKZ 60pcs 0 76 standar card TTL connect wire CRT 500 CB1 Comm wire for extension CRT 500 CB2 25cm CRT 500 CB3 100cm Communication T TTL R RS232 Bezel N No J J Type Bezel Version Serials Number 1 9 Client Code 0 0 Standard Product XX Custom...

Page 6: ...zed Card Dimensions Size 55mm 86mm Thickness 0 20mm 1 2mm require customization Ex work standard card thickness is 0 8 mm Weight 2 0 Kg Approx Dimensions Refer to 4 2 Machanical Drawing Card Stacking Capability 120pcs in case of 0 76mm standard card Available to set to 500pcs max Card Pre Empty Detection 7 50pcs 2pcs Default setting 15pcs Enviromental Condition Operation 0 50 0 90 RH Without Conde...

Page 7: ...enient and inaccurate gap adjustment defects With this feature CRT 541 is quite suitable for the unattended vending devices to dispense various cards of distinct thickness There are several steps to adjust the thickness of cards 1 Confirm the thickness of cards Raised type character are not involved in 2 Push the turn knob and turn around to the graducation pointed by the red arrow Seeing pictures...

Page 8: ... î î ø Ö Ð Ð ú Æ Ã û Æ C R T 541 Ï µ Á Ð µ ç ú C R T 541 001 N X 10 20 30 40 50 60 70 92 98 80 5 M ax 125 8 110 M ax 187 Ô Ø ê 0 76m m 140PC S 37 75 38 5 82 17 17 9 6 4 0 166 4 2 CRT 541 Have bezel 1 8 5 0 3 6 À 0 05 ê Ç ü Ä Î Ä þ º Å Ê ý È ÕÆ Ú Ç Ö 2 3 1 4 5 6 18 À 0 07 À 0 10 À 0 15 À 0 21 À 0 15 À 0 18 À 0 25 À 0 30 À 0 40 À 0 35 À 0 52 À 0 62 À 0 74 À 1 00 Ü 3 À 0 02 À 0 10 À 0 25 2 5 0 5 0 0 ...

Page 9: ...ation Mode 4 31 RS 232 Communication Interface Baud rate BPS 9600 bps Communication type Asynchronous communication Transmit type Half duplex 4 32 Frame Bit Details Start bit 1 bit Data bit 8 bits Parity bit None Stop bit 1 bit 4 33 Frame Structure Diagram 1 0 D0 D1 D2 D3 D4 D5 D6 D7 Data bit Start bit ...

Page 10: ...od as follow BCC STX dispenser address high byte dispenser address low byte command high byte command low byte ETX means XOR 2 Data package transfer by ASCII 3 Find command in Command list 4 Data in below table are valid value of address and all of them are character type 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 4 4 2 2 From Unit To Host Total 7 Bytes in Length STX Dispenser Address High By...

Page 11: ...8400baud 4 4 4 Working Status Response Datasheet The following table shows working status response datasheet Status Code Specification Dispenser is ready 0 0x30 Response this status while dispenser is waiting for command Dispenser dispensing card 1 0x31 Response this status while dispensing card Last dispensing success 3 0x33 Response this status while receive the first Enquiry command after card ...

Page 12: ...owing table shows stacker status response datasheet Status Code Specification Full of cards in stacker 0 0x30 There are enough cards in stacker Lack of card in stacker 1 0x31 Card is not sufficient please replenish cards No card in stacker 2 0x32 There is no card in stacker Note Data in parentheses is the hex value of matched ASCII ...

Page 13: ...response or BCC error NAK ADDRESS ADDRESS is the address of dispenser 2 bytes If the address is not matched data package cannot be re sent by unit 2 The host must re send command package when connect with PC again after receiving negative response If it is still not correct after several re send suggest the host alarm and the user to check the communication circuit 3 The host must not send nonexis...

Page 14: ...till turn to 5 1 1 process 5 1 3 Received dispensing command while dispenser error The host The unit Inquiry command ACK ADDRESS Dispenser error Waiting for a while 200ms Repeat above communication process twice suggest the host alarm error Note 1 The host should not communicate with another unit before the ending of communication with one unit to guarantee the communication fluency 2 ACK ADDRESS ...

Page 15: ...12 16 6 Munti Unit Communication Setting 6 1 Sketch map of Multi Unit PCB The following diagram show the PCB of Multi Unit CRT 541 Note 1 232 ZIP Two 232 interfaces complete the same One connects to extension 2 DIP ZIP The multi switch used to distribute the address of dispenser ...

Page 16: ...Unit Address Multi switch 4 3 2 1 Corresponding address ON ON ON ON 00 ON ON ON OFF 01 ON ON OFF ON 02 ON ON OFF OFF 03 ON OFF ON ON 04 ON OFF ON OFF 05 ON OFF OFF ON 06 ON OFF OFF OFF 07 OFF ON ON ON 08 OFF ON ON OFF 09 OFF ON OFF ON 10 OFF ON OFF OFF 11 OFF OFF ON ON 12 OFF OFF ON OFF 13 OFF OFF OFF ON 14 OFF OFF OFF OFF 15 Note Address default setting is 15 ...

Page 17: ...e corresponding 7 2 Cautions For Safe Use 1 Ensure the power is off while repairing the whole machine 2 Notice the cathode and anode of the machine power while power on for the first time 3 Notice the Specification of JUMP when using for the first time because improper JUMP will cause work off or unpredictable status 4 Prohibit to inset or pull out the receptacle of the port when power on Otherwis...

Page 18: ...ter exceeding guarantee period We will take some material fee if need to replace fittings And we will take some upkeep in the follows situations although it is in guarantee period a Damage and trouble caused artificially b Damage and trouble caused by non professional operation c Damage and trouble caused by instability of user s power supply d Damage and trouble caused by force majeure such as ea...

Reviews: