background image

 

Temperature Measurement Software 

 

1. 

 

Find the ODS setup software in the SD card.

  

2.   Right-click on 

ODS_setup_Vx.x.x.x.exe

 and click 

Run as administrator

.

  

 

 

3.   Choose your preferred language, and click 

OK

.

  

 

 

 

4.   Follow the instructions until successful installation.

  

 

Summary of Contents for Artemis TI-CS-T11

Page 1: ...TI CS T11 Quick Guide Product By CreativeStar Solutions 1601 Trapelo Road Suite 260 Waltham MA 02451 V1 0 3 June 2020 ...

Page 2: ...ments Recommended configuration CPU i7 16GB RAM Window 7 or Window 10 The software and electronic manuals are stored on the SD card that comes with the package Please unzip the files to the folder as required and install the software ...

Page 3: ...erly then twist the metal lock ring clockwise and then complete the installation after hearing a click When releasing the plug please twist the plug counterclockwise and pull the plug away from the receptacle Note After being powered on the equipment needs about half an hour to warm up and adapt to the ambient temperature before it can accurately and stably measure temperature Tips You can power o...

Page 4: ...infrared transmission especially air flow air transmission rate environmental humidity environment temperature and other factors Therefore it is strongly recommended that you install the camera indoor and choose an appropriate installation height and temperature measurement distance Recommended height 1 8 2 meters Effective working distance 2 5 meters Optimal temperature measurement distance 2 3 m...

Page 5: ...5 ...

Page 6: ...USB flash disk or a SD card that comes with the package Thermal Scanner Software 1 Find the T11 setup software in the SD card 2 Right click on T11_setup_Vx x x x exe and click Run as administrator 3 Choose your preferred language and click OK 4 Follow the instructions until successful installation ...

Page 7: ...7 ...

Page 8: ... Software 1 Find the ODS setup software in the SD card 2 Right click on ODS_setup_Vx x x x exe and click Run as administrator 3 Choose your preferred language and click OK 4 Follow the instructions until successful installation ...

Page 9: ...9 ...

Page 10: ...u Control Panel Network and Sharing Center or Network and Internet Network and Sharing Center 2 Click Change adapter settings 3 Right click on Ethernet and click Properties 4 Select Internet Protocol Version 4 TCP IPv4 and click Properties ...

Page 11: ...11 5 Set the IP address to 192 168 1 XXX Note XXX can be set to1 255 except for 64 and 65 6 Click OK ...

Page 12: ...rator Note Please keep this server running and do NOT close the window when you are running the T11 temperature measurement software You can minimize the window of the Human body temperature measuring server 2 Right click on the TI CS T11 icon and click Run as administrator to start the thermal scanner software ...

Page 13: ...and Password and click Login Username admin Password Abc 12345 4 Click Info Mgt Video Manager 5 Click Add The Add Video dialog box displays 6 Add IP Address 192 168 1 64 for Light Video 192 168 1 65 for IRD Video 7 Click Save ...

Page 14: ...ctions until successful installation 4 Open IE browser and type in 192 168 1 65 Note It is recommended to use the 32 bit Internet Explorer to configure the Thermal Scanner Software The Google Chrome browser is also supported however you may not be able to view the real time scene 5 Enter the username and password and click Login Username admin Password Abc 12345 Note You can switch languages at th...

Page 15: ...15 6 Click the Setting tab 7 On the Body temperature detection sub tab select the Body temperature detection enable checkbox ...

Page 16: ...the blackbody is not used the Blackbody real time calibration checkbox must be deselected Otherwise the test result may be incorrect 9 Click redraw blackbody area to draw a proper rectangle or square at the center of the blackbody furnace Note After drawing the blackbody area the blackbody shall always be kept at the original position Once the blackbody is moved to a different place you must redra...

Page 17: ...urement Note It may take up to 2 3 minutes for the cameras to finish self diagnosis after each start up Therefore it is recommended that you run the software 2 3 minutes after you power on the equipment In case the camera fails to load into the software please restart the software ...

Page 18: ...evice Manager msi software to start installing the Onvif Device Manager 2 Follow the instructions until successful installation 3 Right click on the Onvif Device Manager icon and click Run as administrator 4 Enter your username and password and click Login Your device will be automatically detected and displayed in the device list Username admin Password Abc 12345 ...

Page 19: ...lly Check the connection and click Refresh From the navigation panel click Add to manually add the two cameras 5 Select a device from the device list e g IPC The device menu displays 6 Click Time settings The Time settings screen displays to the right of the device menu ...

Page 20: ...chronization method as required It is recommended to select the Synchronize with computer time option 9 Click Apply 10 Repeat steps 5 9 to set up the time for the other camera Note Please make sure that you use the same time settings for the two cameras Note For more detailed instructions please refer to the full manual CreativeStar Solutions 1601 Trapelo Road Suite 260 Waltham MA 02451 info cssin...

Reviews: