background image

pg 10 of 19

REF: AC102 - TRENT ACTIVITY CENTRE

AC102a

AC102b

AC102b

AC102d

Installation Instructions

Attach the TIMBER AC101p to the TIMBERS AC102b/c

Using 4x @200mm  M12 SQUARE CUP HEX BOLTS / 4x NYLOCS / 4x RED CAPS

7

8

q

p

p

h

AC102c

AC102c

AC102a

Attach the TIMBERS AC101q and AC102a to the TIMBERS 

AC101/h- AC102b/c/d

Using 8x @200mm  M12 SQUARE CUP HEX BOLTS / 8x NYLOCS / 8x RED CAPS

All manuals and user guides at all-guides.com

Summary of Contents for AC102

Page 1: ...TRENT ACTIVITY CENTRE Installation Instructions REF AC102 TRENT ACTIVITY CENTRE pg 1 of 19 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...lk Pre assembly x1 CLATTERBRIDGE x1 CLATTERBRIDGE 90 x 90 FLOOR x1 1m CLIMBING WALL x1 LEFT SLIDE SIDE x1 RIGHT SLIDE SIDE x1 1m SLIDE x1 ZENITH STANDARD FLOOR 90x90 x1 ROPE CLIMB x1 RAMP ROPE x2 FLAT SIDES x2 GROOVED SIDES All manuals and user guides at all guides com ...

Page 3: ... M12 x 100 Square Cup HEX bolt x2 M12 x 130 Square Cup HEX bolt x4 M12 x 150 Square Cup HEX bolt x34 M12 x 200 Square Cup HEX bolt x82 M12 NYLOC x4 M8 Plastic Cover x1 D Shackle x82 end caps x3 FM40 Brass screws x58 FM80 Brass screws x8 Quicklink x2 M12 x 80 Eyebolt x4 M12 x 130 Eyebolt x4 small end caps All manuals and user guides at all guides com ...

Page 4: ...d 90x90 3000 1 AC102b 90x90 3000 1 AC102c 90x90 3000 1 AC101h 90x90 3000 1 AC101i 90x90 3000 1 AC101j 90x90 965 1 CODE TYPE SIZE QTY AC101k 90x90 1145 3 AC101l 90x90 1145 1 AC101m 90x90 1145 1 AC101o 90x90 2100 2 AC101p 90x90 2400 2 AC101q 90x90 2400 1 AC102a 90x90 2400 3 AC101s 120x90 3455 1 AC101t 120x90 3600 1 AC101v 120x90 3600 1 All manuals and user guides at all guides com ...

Page 5: ...AC102 TRENT ACTIVITY CENTRE Foundation Details 600 Concrete 150 Soil 350 Concrete 150 Soil FIG 1 RAMP CLATTERBRIDGE CROSSING TYRE LOG WALK NET BAR SLIDE 873 91 1023 91 650 All manuals and user guides at all guides com ...

Page 6: ...pg 6 of 19 REF AC102 TRENT ACTIVITY CENTRE MINIMUM SPACE SURFACE AREA Surfacing Details All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 7: ...llow fundation details 1 2 Installation Instructions a b b d h i c c c b b c a Attach the floor to the timbers AC101b c and place the Hexboard on top Using 4x 150mm M12 SQUARE CUP HEX BOLTS 4x NYLOCS 4x RED CAPS CLATTERBRIDGE FLOOR AC102c AC102d AC102b All manuals and user guides at all guides com ...

Page 8: ...S AC101a b c Using 6x 200mm M12 SQUARE CUP HEX BOLTS 6x NYLOCS 6x RED CAPS Attach the timbers AC101l k to the TIMBERS AC101a Using 4x 200mm M12 SQUARE CUP HEX BOLTS 4x NYLOCS 4x RED CAPS 3 4 Installation Instructions t v a a a l k a c c b b All manuals and user guides at all guides com ...

Page 9: ...1d AC102d Using 6x 200mm M12 SQUARE CUP HEX BOLTS 6x NYLOCS 6x RED CAPS Attach the TIMBER AC101s to the TIMBERS AC101d i h AC102d Using 4x 200mm M12 SQUARE CUP HEX BOLTS 4x NYLOCS 4x RED CAPS 5 6 i h d m k k s d i h b b c c NOTES Attach 800mm x 90mm Slats to 210mm from AC102d AC102d AC102d All manuals and user guides at all guides com ...

Page 10: ...TIMBER AC101p to the TIMBERS AC102b c Using 4x 200mm M12 SQUARE CUP HEX BOLTS 4x NYLOCS 4x RED CAPS 7 8 q p p h AC102c AC102c AC102a Attach the TIMBERS AC101q and AC102a to the TIMBERS AC101 h AC102b c d Using 8x 200mm M12 SQUARE CUP HEX BOLTS 8x NYLOCS 8x RED CAPS All manuals and user guides at all guides com ...

Page 11: ... Attach the RAMP to the AC101c Using 2x 200mm M12 SQUARE CUP HEX BOLTS 2x NYLOCS 2x RED CAPS 10x FM80 Brass Screws RAMP HOLE 148mm from the top of the floor 850mm from the ground 1412mm from the top 9 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 12: ...on Instructions Attach the EYEBOLTS to the TIMBERS AC101l m Using 4x 130mm M12 EYEBOLT 4x NYLOCS 4x RED CAPS Attach the TYRES to the SWING HANGERS Using 1x D SHACKLE 4x M8 Plastic covers 10 11 d a a l AC102d m All manuals and user guides at all guides com ...

Page 13: ...S AC101q AC102b c Using 22x NYLOCS 22x RED CAPS Attach the CLATTERBRIDGE to the EYEBOLTS METAL FLOOR and to the TIMBERS AC101b d AC102d Using 2x 80mm 2x 130mm M12 EYEBOLT 6x NYLOCS 6x RED CAPS 4 QUICKLINKS 12 13 A A A A B b b d A AC102b AC102c AC102d p p All manuals and user guides at all guides com ...

Page 14: ... Instructions Attach the TIMBERS AC101j and 1m CLIMBING HEXBOARD to AC101b c Using 14x FM80 Brass Screws Attach the EYEBOLTS to AC101j and HEXBOARD Using 2x 130mm M12 EYEBOLT 2x NYLOCS 2x RED CAPS 14 15 j c c b b All manuals and user guides at all guides com ...

Page 15: ...RENT ACTIVITY CENTRE Installation Instructions Attach the LOG WALK to the EYEBOLTS and AC101t v Using 4x QUICKLINK 8x NYLOCS 8x RED CAPS 16 A A B B B B A A A A A A A B v t a a b c All manuals and user guides at all guides com ...

Page 16: ...n Instructions Attach STANDARD BAR to the TIMBERS AC101h i Using 4x FM80 Brass Screws 4x Small end caps Attach the RAMP ROPE to the ramp and AC101v Using 2x NYLOCS 2x RED CAPS 17 18 h i v All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 17: ... the SLIDE to the HEXBOARD FLOOR Using 3x FM40 Brass Screws 2x FM80 Brass Screws Insert the SLIDE SIDES to the SLIDE and to the timbers AC101b c 4x FM80 Brass Screws 19 20 b c b c Installation Instructions All manuals and user guides at all guides com ...

Page 18: ... Attach the RAMP and LOG WALK SIDE PANELS Using 14x FM80 Brass Screws 21 Installation Instructions RAMP SIDE PANEL 4x Brass Screw holes each panel LOG WALK SIDE PANEL 3x Brass Screw holes each panel All manuals and user guides at all guides com ...

Page 19: ...pg 19 of 19 REF AC102 TRENT ACTIVITY CENTRE Additional Dimensions All manuals and user guides at all guides com ...