- 10 -
Output rating
Fixed 2.5V/3.3V/5V, 3A
No tracking
Series/Parallel
mode
CH3 does not have tracking series/parallel mode. Also, CH3 output is not affected by CH1 and 2
modes.
Panel operation
1.
Connect the load to the front panel CH3 +/- terminal.
2.
Select the output voltage from 2.5V, 3.3V and 5V, using the CH3
voltage selector switch.
3.
To turn on the output, press the output key. The key LED turns on.
CC to CV
When the output Current level exceeds 3A, the overload indicator turns red and CH3 operation mode
switches from Constant Voltage to Constant Current.
Note: “overload” in this case does not mean an abnormal operation.
3.3 CH1/CH2 Tracking Series Mode
Background
Tracking series operation doubles the Voltage capacity of the power supply series by internally
connecting CH1 (Master) and CH2 (Slave) in series and combining the output to a single channel.
CH1 (Master) controls the combined Voltage output level.
The following describes two types of configurations depending on the common ground usage.