background image

 

Rev 12-31-2018 

GETTING STARTED 

The Pendant works in conjunction with Spikemark and the Showstopper 3 Base to bring the power of 

Spikemark to anywhere in the theater.  Once connected to Spikemark, you are no longer tied to the 

automation table! 

Although the Pendant is portable, it is not indestructible - it’s a little computer after all.  Take care to 

avoid dropping the Pendant, spilling liquids on it and scratching the touch screen. 

FEATURES 

7” Touchscreen 

Network connected device 

Rugged locking cable connectors 

Self terminating Remote E-Stop button 

Factory set with Hold To Run (HTR) functionality 

Jog any motor manually or to a Spike 

Jog motor groups manually 

Use the jog wheel for fine tuning position 

Adjust Spikes on the fly 

Bluetooth keyboard for adjusting default settings  

SETUP 

The Pendant communicates with Spikemark through the same network the Stagehands use.  It is not 

a stand alone controller, but an arm of Spikemark.  Setting up the Pendant is straightforward, with 

only two cable connections and a few IP Addresses you’ll be up and running in no time. 

MAKING THE CONNECTIONS 

The Pendant has two physical connections: 

Showstopper 3 Accessory input 

Network input 

The Accessory input provides power to the Pendant as well as the Remote E-Stop capability.  This 

connection is a standard Showstopper 3 Accessory cable connector, a male Harting style 6B locking 

connector.  The Pendant is self terminating, meaning it will be the final accessory in that line.  It can 

be connected to the system through the Stage Manager or any open Accessory port on a 

Showstopper 3 Base or Hub.   

Network connectivity is provided through a Neutrik EtherCon receptacle.  We like these connectors 

due to their ruggedness but don’t worry if you only have a standard RJ45 cable - they plug right in as 

well.  Once the physical connections are complete, it’s time to set up the network properties. 

Page 3 of 24 

Summary of Contents for Spikemark Pendant

Page 1: ...Spikemark Pendant User Manual V1 0...

Page 2: ...STARTUP AND SHUTDOWN 11 UNDERSTANDING THE DISPLAY 13 STATUS ICONS AND AXIS DETAILS 13 MANUAL JOG 16 JOG WITH THE PADDLE 16 JOG WITH THE JOG WHEEL 17 GROUP JOGGING 17 JOG TO A SPIKE 18 TECHNICAL SUPPO...

Page 3: ...e network the Stagehands use It is not a stand alone controller but an arm of Spikemark Setting up the Pendant is straightforward with only two cable connections and a few IP Addresses you ll be up an...

Page 4: ...lready be filled in for both the computer running Spikemark as well as the Pendant Spikemark IP 192 168 10 245 This is the IP Address of the computer running Spikemark Pendant IP 192 168 10 250 This i...

Page 5: ...ll need to confirm the Spikemark computer IP Address matches what is entered on the Pendant To find your network settings in Windows 10 Press the Start button type Network Status then press Enter On t...

Page 6: ...then click Change adapter options Double click on your adapter from the list Double click on Internet Protocol Version 4 TCP IPv4 Click Use the following IP address radio button Adjust the IP address...

Page 7: ...Rev 12 31 2018 2 Select Configure from the Pendant menu 3 In the Pendant Configuration window enter the computer and pendant IP Addresses if different from the default and click OK Page 7 of 24...

Page 8: ...Rev 12 31 2018 4 Select Enable Pendant from the Pendant menu 5 Select Connect on the Pendant menu Page 8 of 24...

Page 9: ...Rev 12 31 2018 6 Once the Pendant is connected the display will change from the set up screen to the operation interface Page 9 of 24...

Page 10: ...port However it must be enabled every time Spikemark is started before it will be able to connect The Pendant menu within Spikemark has several options Configure IP Address and Port configuration Get...

Page 11: ...will need to pull the accessory cable to restart This method requires the Pendant to be unplugged for approximately 45 seconds before it will restart When updated firmware is released it can be insta...

Page 12: ...e axis you will only see one motor displayed If you are working with more than six axes you can scroll down with the scroll bar or slide the axes up to see additional units Each axis is populated in t...

Page 13: ...Rev 12 31 2018 AXIS STATUS ICONS AXIS LIMIT STATES The Spikes section displays the state of the spikes Page 13 of 24...

Page 14: ...31 2018 SPIKES DISPLAY PARTS SPIKES HIGHLIGHT COLORS Jogging to a Spike outside the soft limits will only jog to the programmed soft limit Spikes can be updated from the Pendant or in Spikemark Page 1...

Page 15: ...on must be pressed and held in order to allow motion JOG WITH THE PADDLE Jogging with the Paddle is the quickest way to move the selected axis or group The Paddle offers proportional control of the se...

Page 16: ...1 when Fine is selected Here s how to jog with the Jog Wheel Select the axis or group Select Jog Mode then select Coarse or Fine Press and hold the green Enable Button Turn the jog wheel Clockwise to...

Page 17: ...s and hold the Enable button The selected Spike will highlight GREEN When the move is complete the Spike will highlight BLUE Jogging to a Spike is only supported on individual axes TECHNICAL SUPPORT W...

Page 18: ...port creativeconners com CASE BUTTONS AND SWITCHES 1 Case is broken a Email support creativeconners com 2 Broken switch knob or lever a Email support creativeconners com CONNECTION ISSUES 1 Pendant co...

Page 19: ...unication 6 Pendant screen displays Network error a Pendant screen will initially flash when attempting to connect then displays Network Error i On subsequent attempts to connect status will switch to...

Page 20: ...d select Paste Can also left click to select and use Ctrl C to copy and Ctrl V to paste It will paste at the top of the list so either scroll up to find it or resort via Name or Group by clicking on t...

Page 21: ...k vi Reopen your show file and restart the Pendant vii Configure both using 9090 in the Port field and attempt to connect viii If the same issue arises repeat the process using another port number Any...

Page 22: ...Voltage 24 VDC Max Input Current 1 25 A SCCR 5000 A Emergency Stop Signal Dual switched channels Communication Ethernet 100mbs etherCON connector Processor Quad Core 1 2GHz Broadcom BCM2837 64 bit ARM...

Page 23: ...Rev 12 31 2018 Dimensions Page 23 of 24...

Page 24: ...Rev 12 31 2018 DRAWINGS Overview https creativeconners com files Drawings Pendant_Overview pdf Page 24 of 24...