7.2. Electrical installation and setup
●
The SmartWasher
®
may only be connected to an
alternating current power supply network. The voltage
indicated on the type plate must correspond to the
voltage of the electrical source. (220 VAC / 50-60 Hz)
●
The equipment may only be connected to an electric
supply that has been installed by a qualified electrician
in accordance with IEC 60364.
●
Any electrical component box may only be opened by
an qualified electrician
●
It is imperative to connect the equipment to the electric
power supply by means of the supplied plug. The plug
serves for the complete disconnection of the equipment
from the main power supply. Do not alter the cable
under any conditions. In case of damages to that cable,
do not repair this cable but substitute by a new one.
●
Check the power cable with mains plug for damage
before every use. If the power cable is damaged, have
it replaced immediately by your local CRC Distributor
or by a qualified electrician in order to avoid possible
hazards.
●
The equipment should be installed in the neighbour-
hood of a normal 220VAC Ground Fault Circuit Inter-
rupter (GFCI) electrical outlet so that it can be plugged
in easily. The SmartWasher
®
should be the only item
plugged into this circuit. The electrical circuit should
be protected by a 30 mA differential switch.
●
The use of an extension cable is authorized. If an
extension cable is used, make sure that this cable is
not damaged by running over, pinching, dragging or
similar. Protect this cable from heat, oil, sharp edges, …
●
The extension cable must have the cross section listed
in the circuit plan and be protected against spraying
water. The connection must not lie in water.
●
Please use the power cable prescribed by the manu-
facturer. The same is also applicable when you replace
the power cable. For type details see chapter 7.1 of
this user instruction manual.
●
If couplings of the power cable or extension cable are
replaced, the splash protection and the mechanical
tightness must be ensured. For connection values, see
type plate/technical data.
●
Never touch the main power plug with wet hands.