Please Read This Before Installing Or Operating Pump. 
This information is provided for 

SAFETY

 and to 

PREVENT 

EQUIPMENT PROBLEMS.

 To help recognize this information, 

observe the following symbols:

IMPORTANT!

 Warns about hazards that can result 

in personal injury orIndicates factors concerned with 
assembly, installation, operation, or maintenance which 
could result in damage to the machine or equipment if 
ignored.

CAUTION!

 Warns about hazards that 

can or will cause minor

 

personal injury or property damage if ignored. Used with symbols 
below.

WARNING!

  Warns about hazards that can or will cause serious 

personal injury, death, or major property damage if ignored. Used 
with symbols below.

Only quali

fi

 ed personnel should install, operate and repair 

pump. Any wiring of pumps should be performed by a quali

fi

 ed 

electrician.

WARNING !

 To reduce risk of electrical shock, pumps 

and control panels must be properly grounded in 
accordance with the National Electric Code (NEC) or 
the Canadian Electrical Code (CEC) and all applicable 
state, province, local codes and ordinances. Improper 
grounding voids warranty.

WARNING!

 To reduce risk of electrical shock, always 

disconnect the pump from the power source before 
handling or servicing. Lock out power and tag. 

WARNING!

 Operation against a closed 

discharge valve will cause premature bearing 
and seal failure on any pump, and on end 
suction and self priming pump the heat build 

may cause the generation of steam with resulting dangerous 
pressures. It is recommended that a high case temperature 
switch or pressure relief valve be installed on the pump body.

 

CAUTION !

 Pumps build up heat and pressure 

during operation-allow time for pumps to cool 
before handling or servicing.

 

WARNING !

 Do not pump hazardous materials 

(

fl

 ammable, caustic, etc.) unless the pump is speci

fi

 cally 

designed and designated to handle them.

 

 

WARNING !

 Do not wear loose clothing that may  

become entangled in moving parts.

  

WARNING !

 Keep clear of suction and discharge 

openings. 

DO NOT 

insert 

fi

 ngers in pump with power 

connected.  

Always wear eye protection when working on pumps. 

Make sure lifting handles are securely fastened each  
time before lifting. 

DO NOT

 operate pump without safety 

devices in place. Always replace safety devices that  
have been removed during service or repair. Secure the 
pump in its operating position so it can not tip over, fall  
or slide.

 

DO NOT

 exceed manufacturers recommendation for 

maximum performance, as this could cause the motor  
to overheat.

 

WARNING !

 To reduce risk of electrical shock, all  wiring 

and junction connections should be made per  the NEC 
or CEC and applicable state or province and  local 
codes. Requirements may vary depending on  usage 
and location.

  

WARNING!

 Products returned must be cleaned, 

sanitized, or decontaminated as necessary prior to 
shipment, to insure that employees will not be exposed 
to health hazards in handling said material. All Applicable 
Laws And Regulations Shall Apply.

 

Bronze/brass and bronze/brass 

fi

 tted pumps may 

contain lead levels higher than considered safe for 
potable water systems. Lead is known to cause cancer 
and birth defects or other reproductive harm. Various 
government agencies have determined that leaded 
copper alloys should not be used in  potable water 
applications. For non-leaded copper  alloy materials of 
construction, please contact factory.

 

Crane Pumps & Systems, Inc. is not responsible for 
losses, injury, or death resulting from a failure to observe 
these safety precautions, misuse or abuse of pumps or 
equipment.

SAFETY FIRST!

Hazardous fl uids can 
cause fi re or explo-
sions, burnes or death 
could result.

Extremely hot - Severe 
burnes can occur on contact.

Biohazard can cause 
serious personal injury.

Hazardous fl uids can Hazard-
ous pressure, eruptions or ex-
plosions could cause personal 
injury or property damage.

Rotating machinery
Amputation or severe 
laceration can result.

Hazardous voltage can 
shock, burn or cause death.

Other brand and product names are trademarks or registered trademarks of their respective holders.
Weinman® is a registered trademark of Crane Pumps & Systems, Inc.
1997, 

7/06, 

9/06 

         Alteration 

Rights 

Reserved

Summary of Contents for Weinman ULL - 7181

Page 1: ...ems Inc constant product improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 119981 Rev E Series ULL and ULL VM Section 1420 Man...

Page 2: ... discharge openings DO NOT insert fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slid...

Page 3: ...er to Lubrication for proper lubrication of the shaft seal and motor bearings Pumps may be installed on any sufficiently solid support since pump and motor are rigidly aligned The Fig 7171 7172 series pumps may be mounted in a vertical position with the motor above the pump liquid end if vertical mounting is preferred PIPING Suction and discharge piping should be direct with as few fittings as pos...

Page 4: ...p To completely dismantle the pump follow to order listed below or select sections applicable to make required repairs All gaskets and o rings should be replaced with new parts at reassembly DISASSEMBLY A To inspect or replace impeller and suction cover impeller or suction cover rings if furnished Remove drain plugs and any external piping Fig ULL 1 Remove capscrews 215 and suction cover 9 2 Remov...

Page 5: ...g certain that end of sleeve is seated against shoulder of motor shaft Note This operation must be done rapidly without allowing the shaft sleeve to cool Do Not allow the sleeve to stop before it is properly seated 6 Hold shaft sleeve snug against the shaft shoulder until shrink begins Allow the sleeve to cool below 100ºF before proceeding with pump assembly 7 Replace deflector 40 on the motor sha...

Page 6: ... or foot valve to see that it is not plugged or buried in mud or sediment When installing in pond or lake support the suction line so that it will be submerged in water but nut imbedded in mud or sediment A strainer with greater screen area may be required d Add sufficient pipe to keep the submerged end well below the water surface e If caused by suction pipe friction increase the size of the pipe...

Page 7: ...Impeller Screw Impeller Key Deflector Base Suction Elbow Handhole Cover Adapter Seal Head Gasket Shaft Seal Pipe Plug Cap Screw Cap Screw Pipe Plug O ring Cap Screw Cap Screw O ring Cap Screw Handhole Cover Cap Screw Cap Screw Gasket Motor Washer Seal Retainer Pipe Plug Gasket Pipe Plug Machine Screw Pipe Plug Impeller Washer Pipe Nipple Gasket Set Recommended Spare Parts Figure ULL Figure ULL VM ...

Page 8: ...formance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS ANALYSES AND EVALUATI...

Page 9: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Crane Pumps...

Page 10: ...__ Type _________________________________ Number and size of short circuit device s ___________ Amp rating ___________________ Overload Type _____________ Size ______________ Amp rating ___________________ Do protection devices comply with pump and motor Amp rating YES___ NO___ Are all electrical and panel entry connections tight YES___ NO___ Is the interior of the panel dry YES___ NO___ Liquid le...

Page 11: ...s installed away from turbulence YES___ NO___ Is level control operating properly YES___ NO___ Is pump fully submerged during operation YES___ NO___ Follow up Corrective Action Required YES___ NO___ Additional Comments ____________________________________________________________________________ ____________________________________________________________________________ ___________________________...

Page 12: ...Notes ...