background image

 

 

BEFORE EACH USE 

 

CHECK VAPORIZER PLACEMENT 

Place the Vaporizer in a stable position on a firm, flat surface at least four feet away 
from bedside and out of reach of children.   
  

 

Protect floor, rug or furniture by placing the vaporizer on a non-metallic, water 
proof, heat-resistant surface. 

 

DO NOT

 direct steam flow directly at user, walls, or furniture.   

 

DO NOT

 place the vaporizer on or near wood, or furniture that can be damaged 

by too much moisture. 

 

KEEP OUT OF REACH OF CHILDREN.  Steam can cause burns.  

 

CAUTION 

 
DO NOT operate the vaporizer without water in the Water Tank. 
 
DO NOT plug or unplug the Power Cord with wet hands as electric 
shock could occur. 
 

OPERATION AND USE

 

 

1.

 

UNRAVLE CORD BEFORE USE.  

Failure to do so could cause overheating and 

possible fire hazard.

 

 
NOTE:

 Always unplug cord from electrical outlet before removing steam unit and 

when vaporizer is not in use.  Always allow vaporizer to cool completely before 
moving, cleaning, or storing. 
 

2.

 

FILL WATER TANK.

  Remove steam unit.  Fill 

water tank with tap water to 

water fill line

 on 

water tank.   
 

CAUTION:

 Do not overfill.   

 

3.

 

ADD SALT.

  Add approximately 1/8 teaspoon of 

salt to the water and mix thoroughly.  It is 
imperative to mix thoroughly.  The salt has no 
effect on the purity of the steam or medication. 
 

CAUTION:  

Too much salt can cause 

excessive boiling or blown fuse. 

 

4.

 

REPLACE STEAM UNIT.

  Hold down 

steam unit for ten seconds to allow 
water to enter the housing and seat it 
properly in the water tank.  If steam 
unit floats, container is overfilled. 

 

Summary of Contents for EE-8619B

Page 1: ...E 8619B EE 8619R EE 8619Y PLEASE READ AND SAVE ALL INSTRUCTIONS TO ENSURE THE SAFE AND EFFCTIVE USE OF THIS APPLIANCE If you have any questions about the operation of your warm steam vaporizer please contact Crane Customer Care Toll Free 888 599 0992 Email customer service crane usa com ...

Page 2: ...ration and Use P 5 7 Maintenance P 7 Trouble Shooting P 8 Customer Care P 9 Warranty P 10 VAPORIZER MODELS This instruction manual applies to the following models of the Warm Steam Vaporizers product line Color Model Blue EE 8619B Pink EE 8619R Yellow EE 8619Y For information about all CRANE products please visit http www crane usa com ...

Page 3: ... operate the unit with a damaged cord or plug 11 Always place the unit on a smooth flat lint free non metallic waterproof and level surface and position unit away from direct sunlight Keep the cord away from heated surfaces and areas where it could be walked on or tripped over Unplug the unit when not in use and whenever you clean or move the unit 12 Do NOT add medication of any type into the Wate...

Page 4: ...ord must be arranged so that it will not drape over the countertop or tabletop where it can be pulled on by children or accidently tripped over ELECTRIC POWER If the electric circuit is overloaded by other appliances your vaporizer and or appliances may not operate properly The vaporizer should be operated on a separate electrical circuit from other operating appliances POLARIZED PLUG This vaporiz...

Page 5: ...Water Tank 2 Power Cord 3 Medication Cup 4 Steam Unit TECHNICAL SPECIFICATIONS Rating Voltage 120V Frequency 60Hz Power 300W Water Tank Capacity 1 Gallon Run Time Per Tank Up to 24 Hours Humidifying Capacity Up to 250 sq feet ...

Page 6: ...ur OPERATION AND USE 1 UNRAVLE CORD BEFORE USE Failure to do so could cause overheating and possible fire hazard NOTE Always unplug cord from electrical outlet before removing steam unit and when vaporizer is not in use Always allow vaporizer to cool completely before moving cleaning or storing 2 FILL WATER TANK Remove steam unit Fill water tank with tap water to water fill line on water tank CAUT...

Page 7: ...eving steam pressure DO NOT lift or move the vaporizer while it is in use 8 USE FRESH WATER AND MEDICATION Always use fresh water and medication with each use of the vaporizer 9 AFTER EACH USE Empty any unused water from the water tank Shake the water tank gently back and forth to remove any remaining water Rinse container thoroughly drain and wipe with a dry clean cloth Discoloration Black Partic...

Page 8: ...aking with fingers covering the bottom holes of the steam unit add tap water to the steam outlet Cover steam outlet with finger from other hand shake vigorously then empty the water through the steam outlet Repeat several times until black particles are no longer emitted and vinegar odor is gone 6 Be sure that steam outlet and water intake holes in the bottom of the steam unit are open and not clo...

Page 9: ...and allow to cool Pour out water and rinse container Rinse steam unit as described in Weekly Maintenance Refill with fresh water but DO NOT ADD SALT If vaporizer now does not operate or steams too slowly see directions above If vaporizer operates too fast fuse blows you may live in an area where minerals in the water caused the vaporizer to steam too rapidly Disconnect vaporizer from electrical ou...

Page 10: ...60106 Toll Free 1 888 599 0992 Monday Friday 9 00am 4 00pm CST Email customer service crane usa com Website http www crane usa com ENVIRONMENTAL PROTECTION If the vaporizer should no longer operate please be sure to dispose of the unit in an environmentally friendly way by taking it into a public collection point Please do not place broken vaporizers with your regular household waste ...

Page 11: ...y to the original purchaser and does not extend to subsequent owners of the product Liability under this warranty is limited to repair or replacement In no event shall liability exceed the purchase price paid by the purchaser of the product Under no circumstances shall there be liability for any loss direct indirect or incidental or consequential damage arising out of or in connection with the use...

Reviews: