background image

 

 

TABLE OF CONTENTS 

 
 

 
 

CRANE & SUSTAINABILITY 

 

Crane USA is dedicated to your environment both 
inside and outside your home.  We know if 
cleaned and maintained properly, our products 
last for years helping to reduce unnecessary use of 
resources and emissions making new products. 
 

The Crane manual you are holding is from recycled materials with 
no added finishes or harmful dyes.  If the humidifier should no 
longer operate, please be sure to dispose of the unit in an 
environmentally friendly way by taking it to a public collection 
point. 
 

PLEASE DO NOT PLACE BROKEN HUMIDIFIERS WITH YOUR REGULAR 

HOUSEHOLD WASTE.

 

 
 

Table of Contents 

P. 1 

Safety Instructions 

P. 2-3 

List of Main Parts 

P. 4 

Technical Specifications, Before Use 

P. 5 

Assembly & Operation 

P. 6 

Maintenance & Storage 

P. 7 

Customer Care & Troubleshooting 

P. 8 

Warranty 

P. 9 

Summary of Contents for EE-5951

Page 1: ...951 PLEASE READ AND SAVE ALL INSTRUCTIONS TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS HUMIDIFIER If you have any questions about the operation of your humidifier please contact Crane Customer Care Toll Free 888 599 0992 Email customer service crane usa com ...

Page 2: ...SAVE YOUR DATED PROOF OF PURCHASE You will need this in case of warranty ...

Page 3: ...g is from recycled materials with no added finishes or harmful dyes If the humidifier should no longer operate please be sure to dispose of the unit in an environmentally friendly way by taking it to a public collection point PLEASE DO NOT PLACE BROKEN HUMIDIFIERS WITH YOUR REGULAR HOUSEHOLD WASTE Table of Contents P 1 Safety Instructions P 2 3 List of Main Parts P 4 Technical Specifications Befor...

Page 4: ...f and level surface and position unit away from direct sunlight Keep the cord away from heated surfaces and areas where it could be walked on or tripped over Unplug the unit when not in use and whenever you clean or move the unit 9 Do not add medication of any type into the Water Basin or Water Tank Do not cover any openings on the unit or insert objects into any openings 10 The unit should not be...

Page 5: ... over the countertop or tabletop where it can be pulled on by children or accidently tripped over ELECTRIC POWER If the electric circuit is overloaded by other appliances your humidifier and or appliances may not operate properly The humidifier should be operated on a separate electrical circuit from other operating appliances POLARIZED PLUG This humidifier has a polarized plug one blade is wider ...

Page 6: ...F MAIN PARTS Fig 1 Humidifier Base 1 Power Icon 2 Power Indicator Light 3 Nebulizer Fig 2 Bottom of Water Tank 4 Mist Outlet Channel 5 Water Tank Cap Fig 3 Other Parts 6 Mist Lid 7 Detachable Cord 2 1 4 5 3 6 7 ...

Page 7: ... on an elevated non metallic lint free waterproof level surface at least 2 feet above the floor DO NOT PLACE ON CARPET OR TOWEL The fan vent is located on the bottom of the humidifier base The fan vent MUST NOT be obstructed DO NOT PLACE ON WOOD SURFACE or near furniture that can be damaged by too much moisture CAUTION DO NOT attempt to operate the humidifier without water in the Water Tank DO NOT...

Page 8: ... icon on the humidifier base 4 The Power Indicator Light will illuminate in blue indicating that there is enough water in the Humidifier Base and mist will begin emitting through the Mist Lid 1st Press Humidifier ON Nightlight OFF 2nd Press Humidifier ON Nightlight ON 3rd Press All OFF 5 When the humidifier runs out of water the Power Indicator Light will flash 3 times and beep once before powerin...

Page 9: ...until ready for next use WEEKLY MAINTENANCE 1 Turn off unplug from outlet and empty water from tank base 2 Fill the water tank halfway warm water and add 2 Tablespoons of white vinegar Shake vigorously and let sit for 20 30 minutes Empty tank and rinse with plain water 3 Fill base with warm water add 1 tablespoon of white vinegar and let sit for 30 min Empty base wipe with a dry cloth TIP Clean th...

Page 10: ...re is water in the tank Too much water in the base Empty base and let tank refill the base properly If there is a strange odor Clean the Water Tank with the water and vinegar solution and rinse with clean water Leave the empty Water Tank open for 12 hours without the Water Tank Cap attached in a cool place The mist output volume is low Clean the nebulizer as described in the weekly maintenance Too...

Page 11: ...anty does not apply to normal wear and tear or commercial use In no event shall liability exceed the purchase price paid by the purchaser of the product Under no circumstances shall there be liability for any loss direct indirect or incidental or consequential damage arising out of or in connection with the use of this product This warranty is valid only in the 48 contiguous states plus the Distri...

Page 12: ...10 ...

Reviews: