CAUTION:  Always be sure the purifier is unplugged and switched off before cleaning, 
removing filters or attempting to store the item.  NEVER PLUG OR UNPLUG THE 
PURIFIER WITH WET HANDS. 
 
CLEANING THE WASHABLE PARTICLE FILTER
 

1.

 

Gently remove the particle filter by unwrapping from the HEPA filter. 

2.

 

Rinse the particle filter by hand using only warm water.   
DO NOT place in dishwasher.   
DO NOT use hard solvents or detergents. 

3.

 

Particle filter MUST be thoroughly dry before wrapping it around the HEPA filter.  

 
Note: HEPA Filter should be cleaned once a month by a vacuum cleaner 

 

CLEANING THE AIR PURIFIER 
NOTE: No part of the air purifier should be placed in the dishwasher.  
 
1.

 

Always unplug the unit before cleaning. 

2.

 

Once unplugged, the exterior of the unit may be cleaned by wiping with a lightly 
damp cloth.  
DO NOT ALLOW WATER TO GET INTO THE INTAKE AND OUTLET GRILLS.   
DO NOT USE GASOLINE, POLISH OR ANY CHEMICAL SOLUTION TO CLEAN AIR 
PURIFIER. 

3.

 

The intake grill and outlet grill can be cleaned of dust with a small soft brush. 

4.

 

If you wish to lightly clean the inside of the air purifier, please remove filters and 
ONLY use a dry, soft cloth to lightly wipe down. 

 

STORING YOUR PURIFIER 

 

Store the purifier is a dry location.  Do not place heavy items on top of the purifier 
during storage as this may result in possible damage of the appliance.  Store the cord in 
a clean, dry location away from metal objects.  Always check the plug before use to 
assure metal items have not become attached. 

 

 

 

 

 

CRANE CUSTOMER CARE 

CALL US: 

888-599-0992  (Mon-Fri 9:00am – 4:00pm CST) 

Summary of Contents for EE-5068

Page 1: ...68 PLEASE READ AND SAVE ALL INSTRUCTIONS TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS PURIFIER If you have any questions about the operation of your purifier please contact Crane Customer Care Toll Free 888 599 0992 Email customer service crane usa com ...

Page 2: ...2 SAVE YOUR DATED PROOF OF PURCHASE You will need this in case of warranty PLEASE READ AND SAVE ALL INSTRUCTIONS TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS PURIFIER ...

Page 3: ...als with no added finishes or harmful dyes If the purifier should no longer operate please be sure to dispose of it in an environmentally friendly way by taking it to a public collection point PLEASE DO NOT PLACE BROKEN PURIFIERS WITH YOUR REGULAR HOUSEHOLD WASTE Table of Contents Sustainability P 1 Safety Instructions P 2 3 List of Main Parts Technical Specifications P 4 Air Purifier Filters P 5 ...

Page 4: ... or lift the air purifier Do not pull the cord against or around sharp corners or edges This could result in injury to the user and or damage the cord 13 Never pull on the cord itself to unplug from power outlet 14 ALWAYS turn unit off before unplugging 15 Never block the air openings or place on soft surface such as a bed or sofa as this could cause the unit to tip over thus blocking the air inta...

Page 5: ...and at least 13 A 1625 W and 2 the cord must be arranged so that it will not drape over the countertop or tabletop where it can be pulled on by children or accidently tripped over ELECTRIC POWER If the electric circuit is overloaded by other appliances your purifier and or appliances may not operate properly The purifier should be operated on a separate electrical circuit from other operating appl...

Page 6: ...V Button 3 Fan Speed Button 4 Power Button Fig 2 Main 5 Air Outlet 6 Air Intake Vent Fig 3 Bottom 7 UV Bulb Compartment 8 Washable Particle Filter HEPA Filter TECHNICAL SPECIFICATIONS Rating Voltage 120 V 60 Hz Power Supply 40 W UB Bulb 3 W Weight 7 3 lbs 1 2 3 4 5 6 ...

Page 7: ...ll as 0 3 microns Microns are used to measure the size of these microscopic airborne particles Allergens such as pollen smoke animal dander mold spores and dust get trapped in the HEPA filter Level 3 UV Bulb The ultraviolet bulb helps reduce germs from growing in the HEPA filter NOTE Blue UV Indicator Light indicates that the UV Bulb is ON unless the unit is set to Sleep Mode BEFORE USE 1 Select a...

Page 8: ... time press the button until there are no more indicator lights lit up IMPORTANT NOTE When the unit is not in use please turn the unit off and unplug REPLACING THE HEPA FILTER When the Filter Reset light blinks continuously it is an indication to replace the filter Once you have replaced the filter hold the POWER button down for 5 seconds to reset the system On average the HEPA Filter needs to be ...

Page 9: ...sposal of the old bulb s The UV bulb is designed to provide approximately one year continuous operation After one year the UV bulb s effectiveness is greatly reduced For maximum protection replace after a year or if the blue UV bulb does not illuminate when the UV switch is ON 1 Unplug the unit and turn it upside down Remove the base and filter 2 Slowly loosen the GREEN screw 3 Grasp the wire conn...

Page 10: ...ays unplug the unit before cleaning 2 Once unplugged the exterior of the unit may be cleaned by wiping with a lightly damp cloth DO NOT ALLOW WATER TO GET INTO THE INTAKE AND OUTLET GRILLS DO NOT USE GASOLINE POLISH OR ANY CHEMICAL SOLUTION TO CLEAN AIR PURIFIER 3 The intake grill and outlet grill can be cleaned of dust with a small soft brush 4 If you wish to lightly clean the inside of the air p...

Page 11: ...ions do not work please contact Crane Customer Care If the air flow is reduced Make sure that the intake and outlet grills are not blocked and are free of debris Make sure the washable filter has been cleaned and check your HEPA filter it may need to be replaced If the above solutions do not work please contact Crane Customer Care If blue UV indicator light does not illuminate Check that the UV bu...

Page 12: ...r and tear or commercial use In no event shall liability exceed the purchase price paid by the purchaser of the product Under no circumstances shall there be liability for any loss direct indirect or incidental or consequential damage arising out of or in connection with the use of this product This warranty is valid only in the 48 contiguous states plus the District of Columbia and excludes Puert...

Page 13: ...13 ...

Reviews: