6
CHART ‘A
’
MODEL NO
.
SIZE
IMP
. DIA.
INCHES
(MM)
HP
V
O
LT
PH
HZ
RPM
NEMA ST
AR
T
CODE
FULL LO
A
D
AMPS
SER
VICE
FA
CT
OR
SER
VICE
FA
CT
OR
AMPS
LOCKED RO
T
O
R
AMPS
DRIVER FRAME
CORD P/N
▲
CORD SIZE
CORD O.
D
.
WINDING
RESIST
ANCE
7366N-424-1H-32N
4M
7.87 (200)
7.5
208
3
60
1750
M
35.9
1.2
38.5
206.6 /
103.3
3
125498
8/4 - 18/4
1.12 ±.02
.187 - .748
230
32.4
1.2
34.8
3
125498
8/4 - 18/4
1.12 ±.02
460
16.2
1.2
17.4
3
125497
12/4 - 18/4
.87 ±.02
7366N-424-73-32N
4M
7.87 (200)
7.5
575
3
60
1750
M
13.0
1.2
13.9
82.6
3
125497
12/4 - 18/4
.87 ±.02
1.16
7366N-410-1H-32N
4ML
8.27 (210)
7.5
208
3
60
1750
M
35.9
1.2
38.5
206.6 /
103.3
3
125498
8/4 - 18/4
1.12 ±.02
.187 - .748
230
32.4
1.2
34.8
3
125498
8/4 - 18/4
1.12 ±.02
460
16.2
1.2
17.4
3
125497
12/4 - 18/4
.87 ±.02
7366N-410-73-32N
4ML
8.27 (210)
7.5
575
3
60
1750
M
13.0
1.2
13.9
82.6
3
125497
12/4 - 18/4
.87 ±.02
1.16
7366N-410-1J-32N
4ML
8.66 (220)
10
208
3
60
1750
K
40.4
1.2
44.6
206.6 /
103.3
3
125498
8/4 - 18/4
1.12 ±.02
.187 - .748
230
36.5
1.2
40.3
3
125498
8/4 - 18/4
1.12 ±.02
460
18.3
1.2
20.2
3
125497
12/4 - 18/4
.87 ±.02
7366N-410-74-32N
4ML
8.66 (220)
10
575
3
60
1750
K
14.6
1.2
16.1
82.6
3
125497
12/4 - 18/4
.87 ±.02
1.16
7366N-410-1K-32N
4ML
9.25 (235)
15
208
3
60
1750
E
51.8
1.2
59.0
206.6
3
125498
8/4 - 18/4
1.12 ±.02
.187 - .748
230
46.9
1.2
54.3
3
125498
8/4 - 18/4
1.12 ±.02
460
23.4
1.2
27.2
103.3
3
125497
12/4 - 18/4
.87 ±.02
7366N-410-75-32N
4ML
9.25 (235)
15
575
3
60
1750
E
18.7
1.2
21.7
82.6
3
125497
12/4 - 18/4
.87 ±.02
1.16
▲
CORD SOLD SEP
ARA
TEL
Y.
IMPOR
TANT !
1.) MOISTURE
AND
TEMPERA
TURE
SENSORS
MUST
BE CONNECTED
T
O
V
ALIDA
TE
THE CSA
LISTING.
2.)
A
SPECIAL
MOISTURE SENSOR RELA
Y
IS REQUIRED IN
THE CONTROL
P
ANEL
FOR PROPER OPERA
TION OF
THE MOISTURE SENSORS.CONT
ACT
CP&S
FOR INFORMA
TION
CONCERNING MOISTURE SENSING RELA
YS FOR CUST
OMER SUPPLIED CONTROL
P
ANELS.
3.)
THESE PUMPS
ARE CSA
LISTED FOR PUMPING W
A
TER
AND W
ASTEW
A
TER.
DO NOT USE T
O
PUMP
FLAMMABLE LIQUIDS
. NOT
SUIT
ABLE FOR ENVIRONMENTS
CONT
AINING GASOLINE OR HEXANE.
4.)
INST
ALLA
TIONS SUCH
AS DECORA
TIVE FOUNT
AINS OR W
A
TER FEA
TURES PROVIDED FOR VISUAL
ENJOYMENT
MUST
BE INST
ALLED IN
ACCORDANCE
WITH
THE
NA
TIONAL
ELECTRIC CODE
ANSI/NFP
A
70
AND/OR
THE
AUTHORITY
HA
VING JURISDICTION.
THIS PUMP
IS NOT
INTENDED FOR USE IN SWIMMING PO
OLS, RECREA
TIONAL
W
A
TER P
ARKS, OR INST
ALLA
TIONS IN WHICH HUMAN CONT
ACT
WITH PUMPED MEDIA
IS
A
COMMON OCCURRENCE.
5.)
WINDING RESIST
ANCE ± 7.5%. WINDING RESIST
ANCE MEASURED IN OHMS @ 25°C (BETWEEN LINES)
A
T
MOT
OR LEADS.
6.)
PUMP
RA
TED FOR OPERA
TION
A
T
± 10% VOL
TAGE
A
T
MOT
OR.
7.)
CORD SUFFIX: XF - 50 FEET
, XJ - 75 FEET
, OR XL
- 100 FEET
. CORD SOLD SEP