Airlocks -
If the pump runs but dose not move any
water, an airlock has occurred. An airlock will cause
pump to overheat. If you suspect an airlock unplug
the pump, tip the pump on its side and submerse
in water and restart. Never restart the pump in less
than 1/2 inch of water.
ELECTRICAL CONNECTIONS:
Power Cable -
The cord assembly mounted to the
pump must not be modifi ed in any way. This pump
comes complete with a 3 wire cord and 3 prong
grounded plug that must be connected into a 3
wire grounded Ground Fault receptacle.
DO NOT
remove ground pin from electrical plug. It is
NOT
recommended to use an extension cord with this
pump. Never place pump in water or remove from
water while the unit is plugged in.
DO NOT USE
THE POWER CABLE TO LIFT PUMP.
Overload Protection -
Automatic thermal overload
protects the motor. Running dry may overheat the
motor and trip the overload. This means that the
overload protector will trip out and shut the pump off
if the windings become too hot, or the load current
passing through them becomes too high. It will then
automatically reset and start the pump up after the
motor cools to a safe temperature. In the event of
an overload, the source of this condition should be
determined and rectifi ed immediately.
DO NOT LET
THE PUMP CYCLE OR RUN IF AN OVERLOAD
CONDITION OCCURS !
SERVICE AND REPAIR:
Strainer -
Remove screws, and remove strainer
from volute and remove volute. Clean and examine
impeller. If impeller vanes are clogged, or it is
excessively worn or broken, the pump should be
replaced.
WARRANTY
:
Information Needed:Always furnish the following
information:
1. Pump Part Number
2. Pump model number
3. Pump Serial number
Typical Name Plate
IMPORTANT !
WARRANTY REGISTRATION
Your product is covered by the enclosed Warranty.
Complete the Warranty Registration Form and
returned to Crane Pumps & Systems, Inc. Warranty
Service Group
IMPORTANT!
If you have a claim under the
provision of the warranty, contact your local Crane
Pumps & Systems, Inc. Distributor.
RETURNED GOODS:
Return Of Merchandise Requires A
“Returned
Goods Authorization”
. Contact Your Local Crane
Pumps & Systems, Inc. Distributor.
Products Returned Must Be
Cleaned, Sanitized, Or Decontami-
nated As Necessary Prior To Ship-
ment, To Insure That Employees
Will Not Be Exposed To Health
Hazards In Handling Said Material.
All Applicable Laws And Regulations Shall Apply.
Summary of Contents for BARNES UT17