background image

Airlocks -

 If the pump runs but dose not move any 

water, an airlock has occurred. An airlock will cause 
pump to overheat. If you suspect an airlock unplug 
the pump, tip the pump on its side and submerse 
in water and restart. Never restart the pump in less 
than 1/2 inch of water.

ELECTRICAL CONNECTIONS:

Power Cable -

 The cord assembly mounted to the 

pump must not be modifi ed in any way. This pump 
comes complete with a 3 wire cord and 3 prong 
grounded plug that must be connected into a 3 
wire grounded Ground Fault receptacle. 

DO NOT

 

remove ground pin from electrical plug. It is 

NOT

 

recommended to use an extension cord with this 
pump. Never place pump in water or remove from 
water while the unit is plugged in. 

DO NOT USE 

THE POWER CABLE TO LIFT PUMP.

Overload Protection -

 Automatic thermal overload 

protects the motor. Running dry may overheat the 
motor and trip the overload. This means that the 
overload protector will trip out and shut the pump off 
if the windings become too hot, or the load current 
passing through them becomes too high. It will then 
automatically reset and start the pump up after the 
motor cools to a safe temperature. In the event of 
an overload, the source of this condition should be 
determined and rectifi ed immediately. 

DO NOT LET 

THE PUMP CYCLE OR RUN IF AN OVERLOAD 
CONDITION OCCURS !

SERVICE AND REPAIR: 

Strainer -

 Remove screws, and remove strainer 

from volute and remove volute. Clean and examine 
impeller. If impeller vanes are clogged, or it is 
excessively worn or broken, the pump should be 
replaced.

WARRANTY

:

Information Needed:Always furnish the following 
information:

1. Pump Part Number
2. Pump model number
3. Pump Serial number

Typical Name Plate

IMPORTANT !
WARRANTY REGISTRATION

Your product is covered by the enclosed Warranty. 
Complete the Warranty Registration Form and 
returned to Crane Pumps & Systems, Inc. Warranty 
Service Group

IMPORTANT!

 If you have a claim under the 

provision of the warranty, contact your local Crane 
Pumps & Systems, Inc. Distributor.

RETURNED GOODS:

Return Of Merchandise Requires A 

“Returned 

Goods Authorization”

. Contact Your Local Crane 

Pumps & Systems, Inc. Distributor.

Products Returned Must Be 
Cleaned, Sanitized, Or Decontami-
nated As Necessary Prior To Ship-
ment, To Insure That Employees 
Will Not Be Exposed To Health 
Hazards In Handling Said Material. 

All Applicable Laws And Regulations Shall Apply.

Summary of Contents for BARNES UT17

Page 1: ...457 2650 www cranepumps com Form No 113829 Rev F SPECIFICATIONS DISCHARGE 3 4 G H T Male Vertical LIQUID TEMPERATURE 77 F 25 C Continuous MOTOR HOUSING Thermoplastic PUMP STRAINER Thermoplastic IMPELLER 2 Vane Semi Open Thermoplastic SHAFT Steel O RINGS Buna N HARDWARE Stainless Steel CABLE ENTRY 15 Ft 4 5M Cord with Plug and Pressure Grommet for Sealing and Strain Relief CABLE TYPE 18 3 SJTW SEAL...

Page 2: ...ould not be used in potable water applications For non leaded copper alloy materials of construction please contact factory Crane Pumps Systems Inc is not responsible for losses injury or death resulting from a failure to observe these safety precautions misuse or abuse of pumps or equipment GENERAL INFORMATION To The Purchaser Congratulations You are the owner of one of the finest pumps on the ma...

Page 3: ...nd start the pump up after the motor cools to a safe temperature In the event of an overload the source of this condition should be determined and rectified immediately DO NOT LET THE PUMP CYCLE OR RUN IF AN OVERLOAD CONDITION OCCURS SERVICE AND REPAIR Strainer Remove screws and remove strainer from volute and remove volute Clean and examine impeller If impeller vanes are clogged or it is excessiv...

Page 4: ...formance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS ANALYSES AND EVALUATI...

Page 5: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Crane Pumps...

Page 6: ...Notes ...

Reviews: