6
CHART ‘A
’
MODEL
NO
HP
V
O
LT
PH
Hz
RPM (Nom)
NEMA ST
AR
T
CODE
FULL LOA
D
AMPS
SER
VICE
FA
CT
OR
SER
VICE
FA
CT
OR
AMPS
LOCKED R
O
T
OR
AMPS
CORD P/N
▲
CORD SIZE
CORD O.
D
.
WINDING
RESIST
ANCE
SITHE SCMD
Pump
4SCMD20064
20.0
208
3
60
1750
G
63.0
1.2
74.6
323.0
138318
6/4 - 18/4
1.14 ± .03
0.098
4SCMD25094
25.0
208
3
60
1750
G
77.8
1.2
93.4
359.0
138319
2/4 - 18/4
1.47 ± .03
0.098
230
71.4
1.2
82.3
4SCMD30094
30.0
208
3
60
1750
E
93.4
1.2
116.9
359.0
138319
2/4 - 18/4
1.47 ± .03
0.098
230
82.3
1.2
98.7
4SCMD40034
40.0
230
3
60
1750
E
106.0
1.2
126.4
486.0
138319
2/4 - 18/4
1.47 ± .03
.063
4SCMD40044
40.0
460
3
60
1750
E
53.0
1.2
63.2
243.0
138318
6/4 - 18/4
1.14 ± .03
.248
4SCMD40054
40.0
575
3
60
1750
E
42.4
1.2
50.6
194.4
138317
8/4 - 18/4
1.12 ± .02
.382
SITHE SCMB Pump
4SCMB20064
20.0
208
3
60
1750
G
63.0
1.2
74.6
323.0
138318
6/4 - 18/4
1.14 ± .03
0.88 - 2.14
4SCMB25094
25.0
208
3
60
1750
G
77.8
1.2
93.4
359.0
138319
2/4 - 18/4
1.47 ± .03
0.098
230
71.4
1.2
82.3
4SCMB30094
30.0
208
3
60
1750
E
93.4
1.2
116.9
359.0
138319
2/4 - 18/4
1.47 ± .03
0.098
230
82.3
1.2
98.7
4SCMB40034
40.0
230
3
60
1750
E
106.0
1.2
126.4
486.0
138319
2/4 - 18/4
1.47 ± .03
0.063
4SCMB40044
40.0
460
3
60
1750
E
53.0
1.2
63.2
243.0
138318
6/4 - 18/4
1.14 ± .03
0.248
4SCMB40054
40.0
575
3
60
1750
E
42.4
1.2
50.6
194.4
138318
6/4 - 18/4
1.12 ± .02t
0.382
SITHE SCME Pump
4SCME30094
30.0
208
3
60
1750
E
93.4
1.2
116.9
359.0
138319
2/4 - 18/4
1.47 ± .03
0.098
230
82.3
98.7
4SCME40034
40.0
230
3
60
1750
E
106.0
1.2
126.4
486.0
138319
2/4 - 18/4
1.47 ± .03
.063
4SCME40044
40.0
460
3
60
1750
E
53.0
1.2
63.2
243.0
138318
6/4 - 18/4
1.14 ± .03
.248
4SCME40054
40.0
575
3
60
1750
E
42.4
1.2
50.6
194.4
138317
8/4 - 18/4
1.12 ± .02
.382
4SCME50044
50.0
460
3
60
1750
F
67.1
1.2
79.0
339.0
138318
6/4 - 18/4
1.14 ± .03
.15
4SCME50054
50.0
575
3
60
1750
F
53.7
1.2
63.2
271.2
138318
6/4 - 18/4
1.14 ± .03
.245
4SCME20096
20.0
208
3
60
1150
H
60.3
1.2
71.5
354.0
138318
6/4 - 18/4
1.14 ± .03
.111
7
230
57.2
1.2
69.8
SCMEA Pump
4SCMEA20096
20.0
208
3
60
1150
H
60.3
1.2
71.5
354.0
138318
6/4 - 18/4
1.14 ± .03
0.1
117
230
57.2
1.2
69.8
4SCMEA25096
25.0
208
3
60
1150
G
75.2
1.2
90.8
354.0
138319
2/4 - 18/4
1.47 ± .03
0.1
117
230
70.8
1.2
82.6
4SCMEA25046
25.0
460
3
60
1150
G
35.4
1.2
41.3
177.0
138317
8/4 - 18/4
1.12 ± .02
0.4397
4SCMEA25056
25.0
575
3
60
1150
G
28.3
1.2
33.0
141.6
138317
8/4 - 18/4
1.12 ± .02
0.6857
Moisture and
Temperature sensor leads are integral to power cord.
Winding Resistance ± 7.5%
Winding resistance measured in OHMS @ 25°C (Between Lines) at motor leads.
Pump rated for operation at ± 10% voltage at motor
.
▲ Cord Suffix: XF - 50 Feet, XJ - 75 Feet, or XL
- 100 Feet
▲ Cord sold separately
.