background image

3

Please Read This Before Installing Or Operating Pump. 
This information is provided for 

SAFETY and to PREVENT 

EQUIPMENT PROBLEMS

. To help recognize this information, 

observe the following symbols:

IMPORTANT!

 Warns about hazards that can result 

in personal injury or Indicates factors concerned with 
assembly, installation, operation, or maintenance which 
could result in damage to the machine or equipment if 
ignored.

CAUTION !

 Warns about hazards that can or will cause minor 

personal injury or property damage if ignored. Used with symbols 
below.

WARNING !

  Warns about hazards that can or will cause serious 

personal injury, death, or major property damage if ignored. Used 
with symbols below.

Only qualifi ed personnel should install, operate and repair 
pump. Any wiring of pumps should be performed by a qualifi ed 
electrician.  

WARNING ! -

 To reduce risk of electrical shock, pumps 

and control panels must be properly grounded in 
accordance with the National Electric Code (NEC) or the 
Canadian Electrical Code (CEC) and all applicable state, 
province, local codes and ordinances. 

WARNING! -

 To reduce risk of electrical shock, always 

disconnect the pump from the power source before 
handling or servicing. Lock out power and tag.

WARNING!

 Operation against a closed 

discharge valve will cause premature bearing 
and seal failure on any pump, and on end 
suction and self priming pump the heat build 

may cause the generation of steam with resulting dangerous 
pressures. It is recommended that a high case temperature 
switch or pressure relief valve be installed on the pump body.

CAUTION !

 Never operate a pump with a plug-in  type 

power cord without a ground fault  circuit interrupter.

CAUTION! 

Pumps build up heat and pressure 

during operation-allow time for pumps to cool 
before handling or servicing. 

WARNING!

 - 

DO NOT

 pump hazardous materials 

(fl ammable, caustic, etc.) unless the pump is specifi cally 
designed and designated to handle them.

Do not block or restrict discharge hose, as discharge 
hose may whip under pressure. 

WARNING! - DO NOT

 wear loose clothing that may 

become entangled in the impeller or other moving parts. 

WARNING! - 

Keep clear of suction and discharge 

openings. 

DO NOT

 insert fi ngers in pump with power 

connected.

Always wear eye protection when working on pumps.

Make sure lifting handles are securely fastened each 
time before lifting. 

DO NOT

 operate pump without 

safety devices in place. Always replace safety devices 
that have been removed during service or repair. 
Secure the pump in its operating position so it can not 
tip over, fall or slide.

DO NOT

 exceed manufacturers recommendation for 

maximum performance, as this could cause the motor 
to overheat.

DO NOT

 remove cord and strain relief. Do not connect 

conduit to pump.

WARNING!

 Cable should be protected at all times to 

avoid punctures, cut, bruises and abrasions - inspect 
frequently. Never handle connected power cords with 
wet hands.

WARNING!

 To reduce risk of electrical shock, all wiring 

and junction connections should be made per the NEC 
or CEC and applicable state or province and local 
codes. Requirements may vary depending on usage 
and location.

WARNING!

 Submersible Pumps are not approved for 

use in swimming pools, recreational water installations, 
decorative fountains or any installation where human 
contact with the pumped fl uid is common.

WARNING! 

Products Returned Must Be Cleaned, 

Sanitized, Or Decontaminated As Necessary Prior 
To Shipment, To Insure That Employees Will Not Be 
Exposed To Health Hazards In Handling Said Material. 
All Applicable Laws And Regulations Shall Apply.

 

Bronze/brass and bronze/brass fi tted pumps may 
contain lead levels higher than considered safe for 
potable water systems. Lead is know to cause cancer 
and birth defects or other reproductive harm.Various 
government agencies have determined that leaded 
copper alloys should not be used in potable water 
applications. For non-leaded copper alloy materials of 
construction, please contact factory. 

IMPORTANT! -

 Crane Pumps & Systems, Inc. is not 

responsible for losses, injury, or death resulting from a 
failure to observe these safety precautions, misuse or 
abuse of pumps or equipment.

SAFETY FIRST!

Hazardous 

fl

 uids can 

cause 

fi

 re or explo-

sions, burnes or death 
could result.

Extremely hot - Severe 
burnes can occur on contact.

Biohazard can cause 
serious personal injury.

Hazardous 

fl

 uids can Hazard-

ous pressure, eruptions or ex-
plosions could cause personal 
injury or property damage.

Rotating machinery
Amputation or severe 
laceration can result.

Hazardous voltage can 
shock, burn or cause death.

Summary of Contents for BARNES 4SE-DS Series

Page 1: ...ct improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 105242 Rev V Series 4SE L DS 9 1 4 1 9 HP 1750RPM 60 Hz Single and Double...

Page 2: ...IEW Fig 17 18 DOUBLE SEAL CROSS SECTION Fig 18 19 DOUBLE SEAL EXPLODED VIEW Fig 19 20 PARTS LIST 21 23 RETURNED GOODS POLICY 26 WARRANTY 25 WARRANTY REGISTRATION SPECIAL TOOLS AND EQUIPMENT INSULATION TESTER MEGGER DIELECTRIC TESTER SEAL TOOL KIT see parts list PRESSURE GAUGE KIT see parts list Other brand and product names are trademarks or registered trademarks of their respective holders Barnes...

Page 3: ...ert fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slide DO NOT exceed manufacturers r...

Page 4: ...rrel Cage Induction Insulation Class B Class F on selected models SINGLE PHASE Permanent Split Capacitor PSC Includes overload protection in motor THREE PHASE 200 240 480 is Tri voltage motor 600V Requires overload protection to be included in control panel OPTIONAL EQUIPMENT Seal Material Impeller Trims Additional Cord N C Temperature Sensors with cord for 3 Phase pumps Requires relay in Control ...

Page 5: ... Back side Dynamically balanced ISO G6 3 Material Cast Iron ASTM A 48 Class 30 SHAFT 416 Stainless Steel SQUARE RINGS Buna N HARDWARE 300 Series Stainless Steel PAINT Air dry enamel top coat SEAL Design Tandem Mechanical with Oil Filled reservoir Material Rotating Faces Carbon Stationary Faces Ceramic Elastomer Buna N Hardware 300 series stainless steel CORD ENTRY 30 ft 9 1m Cord Plug on 120 volt ...

Page 6: ...d debris like gravel stones or earth The sump lift station or basin shall be vented in accordance with local plumbing codes This pump is designed to pump sewage effluent or other nonexplosive or noncorrosive wastewater and shall NOT be installed in locations classified as hazardous in accordance with the National Electrical Code NEC ANSI NFPA 70 or the Canadian Electrical Code CEC Never install the p...

Page 7: ...except for shortening to a specific application Any splice between the pump and the control panel must be made in accordance with all applicable electric codes It is recommended that a junction box if used be mounted outside the sump or be of at least Nema 4 EEMAC 4 construction if located within the wet well Do not use the power or control cable to lift pump NOTE The white wire is NOT a neutral or...

Page 8: ...5 5 49 6 28 4SE1944DS 1 9 480 3 60 1750 B B 2 5 7 7 14 4 SOW 0 570 14 5 21 96 24 51 4SE1954DS 1 9 600 3 60 1750 C F 1 9 7 2 14 4 SOW 0 570 14 5 34 36 35 60 Winding Resistance 5 measured from terminal block Pump Rated for Operation at 10 Voltage at Motor OPTIONAL Temperature sensor cord for 3 phase models is 14 3 SOW 0 530 13 5mm O D OPTIONAL Moisture sensor cord is 18 5 SOW 0 470 12mm O D OPTIONAL...

Page 9: ...pump is removed from operation the cooling oil in the motor housing 6 should be checked visually for oil level and contamination F 1 1 Checking Oil Motor Housing To check oil set unit upright Remove pipe plug 39 from housing 6 With a flashlight visually inspect the oil in the motor housing 6 to make sure it is clean and clear light amber in color and free from suspended particles Milky white oil in...

Page 10: ...1 Disassembly and Inspection To clean out volute 1 or replace impeller 33 disconnect power remove hex bolts 26 and lockwasher 12 vertically lift motor and seal plate assembly from volute 1 see Figure 4 Clean out body if necessary Clean and examine impeller 33 for pitting or wear and replace if required inspect gasket 36 and replace if cut or damaged If the impeller 33 needs replacing place a flat s...

Page 11: ...mber 28a firmly into inner seal plate 5 using a seal pusher Nothing but the seal pusher is to come in contact with seal face see Figure 8 IMPORTANT DO NOT hammer on the seal pusher it will damage the seal face Make sure the stationary member is in straight Slide a bullet over motor shaft Lightly oil DO NOT use grease shaft bullet and inner surface of bellows on rotating member 28b see Figure 9 With...

Page 12: ...ng 25 drain oil from motor as outlined in paragraph F 1 1 Disassemble volute and impeller as outlined in paragraph F 2 1 and disassemble shaft seal as outlined in paragraph F 3 1 Position unit upright using blocks to avoid resting unit on shaft Unscrew cable hex bolts 11 and remove compression flange 16a and power cord 16 Remove snap ring 19 with a flat head screwdriver Pull the terminal block 21 ou...

Page 13: ... with motor Motor Slide lower bearing 25 and motor shaft squarely into the seal plate 5 until bearing seats on the bottom Place stator over rotor lining up motor bolts with holes in seal plate 5 Position capacitor 9 single phase units so that it will lay on the opposite side of the cable entry bosses of the motor housing 6 Reconnect capacitor leads Torque motor tie bolts to 17 in lbs Set square ri...

Page 14: ...on This number is used for ordering and obtaining information G 3 MODEL NUMBER This designation consists of numbers and letters which represent the discharge size series horsepower motor phase and voltage speed and pump design This number is used for ordering and obtaining information G 4 SERIAL NUMBER The serial number block will consist of a six digit number which is specific to each pump and may...

Page 15: ...15 FIGURE 15 CONTIUED ...

Page 16: ... Check cutter for freedom of operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the suction is always flooded Clean vent hole 10 Remove examine for damage Replace pump stator if required 11 Repair fixtures as required to eliminate leakage 12 Check pump temperature limits ...

Page 17: ...17 FIGURE 16 4SE L Series Single Seal ...

Page 18: ...18 FIGURE 17 4SE L Series Single Seal ...

Page 19: ...19 FIGURE 18 4SE DS Series Double Seal ...

Page 20: ...20 FIGURE 19 4SE DS Series Double Seal ...

Page 21: ...0oz 029034 Oil All double seal Includes 24oz in Seal Chamber 9 1 034964 Capacitor 30MFD 1 Phase 10 1 039858 Capacitor Bracket 1 Phase 11 4 1 129 1 Hex Hd Cap Screw Std 5 16 18 x 75 Lg Stainless 6 1 129 1 Hex Hd Cap Screw Optional for moisture and temp sensors 12 8 026322 Lockwasher Std 5 16 Stainless 10 026322 Lockwasher Optional for moisture and temp sensors 13 1 103503 Handle 16 1 See Table 2 Po...

Page 22: ...08 Nipple 35 3 003479 Cap 36 1 027344 Gasket 39 1 014270 Pipe Plug 375 NPT ZP 41 A R Loctite242 42 A R Permatex2C 44 1 003217 Pipe Plug All double seal 25 NPT ZP 45 2 5 32 6 Screw Optional for moisture sensor 6 32 x 25 Lg ZP 46 2 052563 Lockwasher Optional for moisture sensor 6 Stl 47 2 084948 Socket Head Screw 1 4 20 x 1 25 Lg Stainless 48 4 105150 Terminal Connector 200 240V 3Ph 3 625 00163 Term...

Page 23: ...sture and Temperature Sensor 3 Phase or Moisture Sensor 8 FT 103756A 103741A 103742A 103741A 113288A 15 FT 103756 103741 103742 103741 113288 20 FT 103756XA 103741XA 103742XA 103741XA 113288XA 30 FT Std 103756XC 103741XC 103742XC 103741XC 113288XC 50 FT 103756XF 103741XF 103742XF 103741XF 113288XF 75 FT 103756XJ 103741XJ 103742XJ 103741XJ 113288XJ 100 FT 103756XL 103741XL 103742XL 103741XL 113288X...

Page 24: ...24 Notes ...

Page 25: ... PXVW EH VLJQHG E RXU DXWKRUL HG UHSUHVHQWDWLYH XH WR LQDFFXUDFLHV LQ HOG WHVWLQJ LI D FRQÀ LFW DULVHV EHWZHHQ WKH UHVXOWV RI HOG WHVWLQJ FRQGXFWHG E RU IRU XVHU DQG ODERUDWRU WHVWV FRUUHFWHG IRU HOG SHUIRUPDQFH WKH ODWWHU VKDOO FRQWURO 5 200 1 7 216 25 63 33 7 216 25 7 26 5 68 7 1 520 6 67 06 1 6 6 1 9 8 7 216 21 8 7 6 21 285 67 9 3 5 1 1 38 6 1 8675 1 250 7 21 68 5 200 1 7 216 2 127 2167 787 55 ...

Page 26: ...ent To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Crane Pump...

Reviews: