4
DISCHARGE ..................
2” NPT, Vertical, Bolt-on Flange
3” NPT, Vertical, Bolt-on Flange
LIQUID TEMPERATURE
104°F (40°C) Continuous
MOTOR HOUSING ........
Cast Iron ASTM A-48, Class 30
VOLUTE .........................
Cast Iron ASTM A-48, Class 30
SEAL PLATE .................
Cast Iron ASTM A-48, Class 30
IMPELLER
Design
...........
Vortex, Open with Pump out vanes
on Back side. Dynamically
balanced, ISO G6.3
Material
........
Cast Iron ASTM A-48, Class 30
SHAFT ............................
416 Stainless Steel
SQUARE RINGS ............
Buna-N
HARDWARE ..................
300 Series Stainless Steel
PAINT .............................
Air dry enamel, top coat
SEAL
Design
..........
Single Mechanical, or Tandem
Mechanical with oil fi lled reservoir
Material
........
Rotating Faces - Carbon
Stationary Faces - Ceramic
Elastomer - Buna-N
Hardware - 300 series stainless steel
CORD ENTRY ................
2” NPT, 20 ft. (6.1m)
3” NPT, 30 ft. (9.1m)
Cord. Plug on 120 volt & .5Hp, 240
volt 1 Phase. Quick connect. Custom
molded for sealing and strain relief
SPEED ...........................
1750 & 3450 RPM, 60Hz (nominal)
UPPER BEARING:
Design
..........
Single Row, Ball, Oil Lubricated
Load
.............
Radial
LOWER BEARING:
Design
..........
Single Row, Ball, Oil Lubricated
Load
.............
Radial & Thrust
MOTOR:
Design
..........
NEMA L, Single phase,
NEMA B, Three Phase Torque Curve,
Oil Filled, Squirrel Cage Induction
Insulation
......
Class B
Class F on selected models
SINGLE PHASE .............
Permanent Split Capacitor (PSC)
Includes overload protection in motor
THREE PHASE ..............
200-240/480 is Tri voltage motor.
600V. Requires overload protection
to be included in control panel
OPTIONAL EQUIPMENT:
Seal Material, Impeller Trims, Additional Cord,
N/C Temperature Sensors with cord for 3 Phase pumps
(Requires relay in Control Panel). N/O Moisture Sensor with
cord for DS pumps (Requires relay in Control Panel), 3” NPT
Discharge Adapter
SECTION: A - PUMP SPECIFICATIONS:
inches
(mm)
2SEV-L Series
Plugs for 120 Volt
and .5Hp, 240
Volt Single Phase
Models.
IMPORTANT !
1.) PUMP MAY BE OPERATED “DRY” FOR EXTENDED PERIODS WITHOUT DAMAGE TO MOTOR AND/OR SEALS.
2.) THIS PUMP IS APPROPRIATE FOR THOSE APPLICATIONS SPECIFIED AS CLASS I DIVISION II HAZARDOUS LOCATIONS.
3.) THIS PUMP IS NOT APPROPRIATE FOR THOSE APPLICATIONS SPECIFIED AS CLASS I DIVISION I HAZARDOUS LOCATIONS.
4.) INSTALLATIONS SUCH AS DECORATIVE FOUNTAINS OR WATER FEATURES PROVIDED FOR VISUAL ENJOYMENT MUST BE INSTALLED IN
ACCORDANCE WITH THE NATIONAL ELECTRIC CODE ANSI/NFPA 70 AND/OR THE AUTHORITY HAVING JURISDICTION. THIS PUMP IS NOT
INTENDED FOR USE IN SWIMMING POOLS, RECREATIONAL WATER PARKS, OR INSTALLATIONS IN WHICH HUMAN CONTACT WITH PUMPED
MEDIA IS A COMMON OCCURRENCE.
Summary of Contents for 104918
Page 16: ...16 FIGURE 15 CONTIUED ...
Page 18: ...18 FIGURE 16 2SEV L 3SEV L Series Single Seal ...
Page 19: ...19 FIGURE 17 2SEV L 3SEV L Series Single Seal ...
Page 20: ...20 FIGURE 18 2SEV DS 3SEV DS Series Double Seal ...
Page 21: ...21 FIGURE 19 2SEV DS 3SEV DS Series Double Seal ...
Page 25: ...25 Notes ...
Page 26: ...26 Notes ...