background image

Summary of Contents for Colovos 351.181700

Page 1: ...81700 Colovos CAUTION Read and follow all Safety Rules and Operating Instructions before First Use of this Product Keep this manual with tool Sears Roebuck and Co Hoffman Estates IL 60179 U S A www sears com craftsman 20801 00 Draft 04 09 03 Safety Operation Maintenance Parts List EspaSol ...

Page 2: ... maximum system pres sure whichever is greater Do not use a hose swivel connector with this tool Do not pull trigger or depress contact trip while connecting to the air supply as the tool may cycle possibly causing injury When loading tool Do not pull trigger or depress contact trip Do not point the tool at yourself or others Do net place hand or any part of body in the fastener discharge area of ...

Page 3: ...r operated tools require clean dry lubricated com pressed air to ensure top performance low maintenance and long life Dirt and abrasive materials present in all air lines will dam age tool O rings valves and cylinders Moisture will reduce tool performance and life if not removed from compressed air A filter regulator lubricator system is required and should be located as close to tool as possible ...

Page 4: ...t to single fire mode the tool will not drive a second fastener until the trigger is fully released and pulled again When the switch is rotated to rapid fire mode the tool can drive fasteners continuously A fastener will be fired each time the contact trip is pressed against the workpiece as long as the trigger is maintained in the pulled position Figure 3 Load Magazine Slide magazine cover forwar...

Page 5: ...rfaces by the contact trip during normal operation Pad can be removed and stored on the storage sleeve located on the end cover of the magazine Rex wrench is also stored on the magazine Figure 7 Storing Contact Trip Pad and Wrench FASTENER VIEW WINDOW This tool has a fastener viewing window on the magazine cover Fasteners are visible through the window see Figure 8 When the pusher is visible throu...

Page 6: ...g properly With the red push button switch in the rapid fire mode per form the following procedures to test safety mechanism Leave trigger untouched while pushing contact trip into workpiece Tool must not fire Pull trigger while contact trip is clear of work and pointed away from operator and others Tool must not fire Depress and hold trigger Push contact trip against work where fastener is needed...

Page 7: ...d bumper 2 Build up on ram or nose 3 4 5 6 Insufficient air supply 3 Damaged or worn piston O ring 4 Damaged magazine springs 5 Magazine nose bolts loose 6 7 Fasteners too short 8 Damaged fasteners 9 Incorrect fastener size 10 Cap leaks 11 Damaged trigger valve seal and O rings 12 Bent or damaged ram 13 Dirty magazine 14 Damaged or worn magazine or magazine cover 1 Check and replace damaged spring...

Page 8: ...Model 351 181700 Figure 10 Replacement Parts Illustration For Stapler 12 2o _t 22 _ 30 24 I 27 V 57_ _ _ I 51 _ 50 47 49 39 35 8 ...

Page 9: ...Staples h Crown Long 5000 9 18331 Staples V2 Crown Long 1000 9 19185 A Staples 2 Crown l Long 4000 9 18379 z Staples V Crown l Long 1000 9 19187 KEY NO 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 A A A PART NO DESCRIPTION 20795 00 20301 00 20796 00 20797 00 20798 00 06086 00 20299 00 17437 00 20300 00 20246 00 20276 00 06080 00 N A 04327 00 20304 00 20...

Page 10: ...lawn equipment and electronics call or go on line for the location of your nearest Sears Parts Repair Center 1 800 488 1222 Call anytime day or night U S A only www sears com To purchase a protection agreement U S A or maintenance agreement Canada on a product serviced by Sears 1 800 827 6655 U S A 1 800 361 6665 Canada Para pedir servicio de reparaci6n a domicilio y para ordenar piezas 1 888 SU H...