19- ENG
D24445
6.
Assemble the regulator and
orient as shown.
NOTE:
Arrow indicates flow of air.
Make sure it is pointing in the
direction of air flow.
7.
Reapply pipe sealant to outlet
pressure gauge and quick
connect.
8.
Reassemble outlet pressure
gauge and quick connect. Orient
outlet pressure gauge to read
correctly. Tighten quick connect
with wrench.
To Replace Regulator
1.
Release all air pressure from air
tank. See “To Drain Tank” in the
Maintenance section.
2.
Unplug outfit.
3.
Remove the outlet pressure
gauge and quick connect (if
equipped) from the regulator.
4.
Remove the regulator.
5.
Apply pipe sealant tape to the
nipple.
Nipple
Outlet
Pressure
Gauge
Quick
Connect
Regulator
Regulator
Arrow
Regulator