7
Function Range
Resolution
Accuracy
200
0.1
(0.8% r 5 digits)
2 k
0.001
k
20 k
0.01
k
200 k
0.1
k
(0.8% r 2 digits)
2 M
0.001
M
Resistance
20 M
0.01
M
(2.5% r 8 digits)
0 to 30
F / -17 to -1
C
15
F / 8.3
C
31 to 150°F / -0.5 to 65
C
6
F / 3.3
C
Temperature IR
151 to 400°F / 66 to 204
C
0.1
C/
F
4.0% of reading
Enclosure
Double molded
Diode Test
Test current of 0.9mA maximum, open circuit voltage 2.8V DC typical
Continuity
Threshold 20 to 50
, test current <1.5mA
Input Impedance
10M
Ω
VDC/VAC
AC Response
True RMS
ACV Bandwidth
40Hz to 1000Hz
IR Spectral response
6 to 16µm
IR Emissivity
0.95 fixed
IR distance ratio
4:1
Laser pointer
Class 2 laser < 1mW power; Wavelength is 630 to 670nm
Display
2,000 count backlit liquid crystal display
Overrange indication
“
OL
” is displayed
Auto Power Off
15 minutes (approximately)
Polarity
Automatic (no indication for positive); Minus (-) sign for negative
Measurement Rate
2 times per second, nominal
Battery
One 9 volt (NEDA 1604) battery
Fuses
mA, µA ranges; 200mA 250V ceramic fast blow
A range; 10A 600V ceramic fast blow
Operating Temperature
-10ºC to 40ºC (14ºF to 122ºF)
Storage Temperature
-10
o
C to 60
o
C (14
o
F to 140
o
F)
Operating Humidity
Max 80% up to 31ºC (87ºF) decreasing linearly to 50% at 40ºC (104ºF)
Storage Humidity
<80%
Operating Altitude
2000 meters (7000 ft) maximum
Weight
260 g (9.17oz)
Size
147x76x42 mm (5.8x2.9x1.6”)
Safety
This meter is intended for origin of installation use and protected, against
the users, by double insulation per IEC/EN 61010-1:2001 and IEC/EN
61010-031:2002 to Category III 600V; Pollution Degree 2.
Approvals
CE