background image

OPERATION 

 
Know your Inflator 

READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT.  
Compare the illustration with your unit to familiarize yourself with the location of various controls 
and adjustments.  Save this manual for future reference.   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Description of Operation 

On/Off Switch: 

Used to turn Inflator on 

and off. 

Pressure Gauge: 

Gives the pressure 

reading in PSI. 

Small Adaptor: 

Attaches directly to 

the Quick-Connect Universal Valve 
Adaptor to inflate small inflatable rafts 
and beach balls. 

Quick-Connect Universal Valve 
Adaptor:

 Used with standard tire 

valves and with accessories included 
with Inflator. 

Air Needle: 

Attaches directly to the 

Quick-Connect Universal Valve 
Adaptor to inflate sport balls. 

 

 

High Flow Inflator/Deflator Adaptor: 

Used with inflator/deflator nozzles, this 
adaptor attaches directly to the Quick-
Connect Universal Valve Adaptor to 
inflate or deflate air mattresses, small 
boats, inflatable toys, and other items 
that require a large volume of low-
pressure air.  

 

Inflator/Deflator Nozzles:

 Used with 

High Flow Inflator/Deflator Adaptor. 

Seal Ring: 

Used with inflator/deflator 

nozzles to prevent air from leaking out 
of inflatables with very large air inlets. 
 

 WARNING: 

 

 

Risk of Bursting.  

Unattended tires, inflatable balls, 
inflatable toys, and other inflatable items 
can over-inflate very quickly, sometimes 
in a matter of seconds, and result in 
personal injury or property damage.   
 

 

10 

Summary of Contents for 75118

Page 1: ...N Read the Safety Guidelines and All Instructions Carefully Before Operating Sears Brands Management Corporation Hoffman Estates IL 60179 U S A Visit our Craftsman website www craftsman com Safety Guidelines Assembly Operation Maintenance Troubleshooting ...

Page 2: ...or warranty coverage details to obtain free replacement visit the web site www craftsman com This warranty does not cover the air needle which is an expendable part that can wear out from normal use within the warranty period This warranty is void if this product is ever used while providing commercial services or if rented to another person This warranty gives you specific legal rights and you ma...

Page 3: ...y equipment always wear MSHA NIOSH approved properly fitting face mask or respirator when using such tools When using air tools basic safety precautions should always be followed to reduce the risk of personal injury This Inflator is designed to inflate car tires bike tires ATV tires sports equipment air mattresses beach toys and other inflatables Do not use for any purpose other than inflating If...

Page 4: ...pors they may ignite causing fire or explosion Store flammable materials in a secure location away from inflator Restricting any of the inflator ventilation openings will cause serious overheating and could cause fire Never place objects against or on top of inflator Operate inflator in an open area at least 12 inches away from any wall or obstruction that would restrict the flow of fresh air to t...

Page 5: ...sult in personal or property damage Always remain in attendance when inflating tires inflatable balls inflatable toys and other inflatable items Be prepared to stop inflator when item is fully inflated sometimes in a matter of seconds HAZARD WARNING Risk from Flying Objects What Could Happen How To Prevent It The inflator air stream can cause soft tissue damage to exposed skin and can propel dirt ...

Page 6: ...ult in serious injury or death from electrocution See grounding instructions Make certain that the electrical circuit to which the inflator is connected provides proper electrical ground correct voltage and adequate fuse protection When operating inflator outdoors use GFCI outlet HAZARD WARNING Risk to Breathing What Could Happen How To Prevent It The compressed air directly from your inflator is ...

Page 7: ...t with you your clothing loose hair or jewelry Never operate the inflator with guards or covers which are damaged or removed Attempting to operate inflator with damaged or missing parts or attempting to repair inflator with protective shrouds removed can expose you to moving parts and can result in serious injury Any repairs required on this product should be preformed by authorized service center...

Page 8: ... operation with a fire extinguisher Do not operate machine with missing broken or unauthorized parts HAZARD WARNING Risk of Injury Do not direct air stream at body Disconnect from supply circuitry before replacing fuse SAVE THESE INSTRUCTIONS GLOSSARY Become familiar with these terms before operating the unit CFM Cubic feet per minute SCFM Standard cubic feet per minute a unit of measure of air de...

Page 9: ...Flow Inflator Deflator Adaptor with three nozzles and seal ring Used to inflate or deflate air mattresses small boats inflatable toys and other items that require large volume of low pressure air ASSEMBLY Contents of Carton To Remove Inflator from Carton 1 Inflator equipped with rubber air hose and pressure gauge 1 Inflation Accessory Kit 1 Air Needle 1 Small Adaptor 1 Presta Valve Adaptor 1 High ...

Page 10: ...MPORTANT The outlet being used must be installed and grounded in accordance with all local codes and ordinances 2 Make sure the outlet being used has the same configuration as the grounded plug DO NOT USE AN ADAPTOR See illustration 3 Inspect the plug and cord before each use Do not use if there are signs of damage 4 If these grounding instructions are not completely understood or if in doubt as t...

Page 11: ...ed with Inflator Air Needle Attaches directly to the Quick Connect Universal Valve Adaptor to inflate sport balls High Flow Inflator Deflator Adaptor Used with inflator deflator nozzles this adaptor attaches directly to the Quick Connect Universal Valve Adaptor to inflate or deflate air mattresses small boats inflatable toys and other items that require a large volume of low pressure air Inflator ...

Page 12: ...late sports ball air mattress rubber raft etc 1 Place 120 Volt Inflator evenly on flat surface 2 Select the appropriate inflation accessory and insert into the Quick Connect Universal Valve Adaptor and push down the Valve Lock Lever to secure the connection 3 Plug the power cord into a grounded 120 Volt outlet NOTE For instructions on how to use High Flow Inflator Deflator Adaptor at this point se...

Page 13: ...Insert nozzle thru seal ring as shown 3 The high flow inflator deflator adaptor has an inflation outlet and deflation outlet Attach the nozzle to the preferred outlet NOTE Inflation and Deflation are marked at outlets Inflation Position Deflation Position 4 Insert nozzle into inflatable and start inflator NOTE If inflatable is not getting firm enough place thumb over the deflation outlet to allow ...

Page 14: ...ore attempting the repairs PROBLEM CAUSE CORRECTION Motor will not run Fuse blown circuit breaker tripped Extension cord is wrong length or gauge Faulty motor 1 Check fuse holder for blown fuse and replace as necessary Reset circuit breaker Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit 2 Check for proper fuse You should be using a 15...

Page 15: ... expert advice www managemylife com For repair in your home of all major brand appliances lawn and garden equipment or heating and cooling systems no matter who made it no matter who sold it For the replacement parts accessories and owner s manuals that you need to do it yourself For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY ...

Reviews: