background image

Summary of Contents for 580.326311

Page 1: ...w all Safety Rules add Operating Instructions ADVEBTENCIA Antes de utilizar el producto lea este manual y siga todas las Reglasde Seguridade Instrucciones de Uso Sears Roebuckand Co Roffrnan Estates IL 60179 U S A Visit our Craftsman website www craftsman com Part No 201492GS Draft C 11 07 2007 Safety Assembly Operation o Maintenance Parts Espafiol p 36 ...

Page 2: ... proves impossible AdditionalOne YearLimited Warrantyon Craftsman Generator For the second year from the date of purchase if any part of this generator fails dueto a defect in material or workmanship a new part will be supplied free of charge You must pay the labor cost if you wish to have it installed All warranty coverageapplies for only 90 days from date of purchase if this generator is used fo...

Page 3: ...ed to holdacartridgewhich containsfuelstabilizer IfSWALLOWED callphysicianimmediately DONOTinduce vomiting If inhaled remove to freshair In caseof eyeor skin contact flushwithwaterfor 15minutes Storeunopened cartridgesina cool dry wellventilated area Keepopencartridgeinfuel cap andfuel capclosedonfueltank whennotin use Inthe caseof anemergency contacta physician immediately andcall 1 808 424 9308 ...

Page 4: ...thing jewelry or anything that may be caught in the starter or other rotating parts Tie up long hair and remove jewelry WARNING Starter cord kickback rapid retraction can result in bodily injury Kickback will pull hand and arm I1_ toward engine faster than you can let go Broken bones fractures bruises or sprains could result When starting engine pull cord slowly until resistanceis felt and then pu...

Page 5: ...ical devices connected to it DONOTexceedthe generator s wattage amperage capacity See Don t OverloadGeneratorin the Operationsection Start generator and let engine stabilize before connecting electrical loads Connect electrical loads in OFFposition then turn ONfor operation Turn electrical loads OFFand disconnect from generator before stopping generator NOTICE Improper treatment of generator can d...

Page 6: ...Lever Usedwhen starting a cold engine CircuitBreakers AC Pushto resetcircuit breakersare providedto protectthe 120VAC 20A duplexreceptaclesagainst electricaloverload DataTag Providesmodel revisionandserial numberof generator Pleasehavethese readilyavailablewhen calling for assistance EngineRocker Switch Recoil Starter Oil Fill Cap Lever Battery Float Start Switch ChargerJack DoublePoleCircuitBreak...

Page 7: ...ls to install these components 13mmwrench Socket wrench with a 13ram socket Pliers Safety glasses install the Wheel Kit as Follows IMPORTANT Installing the wheel kit must be completed prior to adding any oil or fuel 1 Tip generator so that engine end is up 2 Slide axle through both mounting brackets 3 Place a wheel on each side as shown 4 Place a washer on axle and then place an e ring in axle gro...

Page 8: ...e A minimum of 87 octane 87 AK 91 RON Highaltitude use see High Altitude Gasolinewith up to 10 ethanol gasoho or upto f 5 MTBE methyl tertiary butyl ether is acceptable NOTICE Avoid generator damage Failureto follow Operator s Manual for fuel recommendations voids warranty DONOTuseunapproved gasoline suchas E85 DONOTmixoil in gasoline DONOTmodifyengine to runonalternate fuels To protect the fuel s...

Page 9: ...tret butylphenol 128 39 2 and alipbatic petroleum distillate 64742 47 8 1 Place cartridge into fuel cap 2 Push to snap cartridge into place 3 Removetab to expose membrane IMPORTANT DONOTremove the silver foil seal on the opposite side 4 Reinstall fuel cap on fuel tank 5 Periodically check the cartridge to ensure there is still fuel preserver inside If it is empty removecartridge and replace HighAl...

Page 10: ...ic utility workers dueto backfeedof electrical energy Whenusinggenerator for backup power notifyutilitycompany Useapproved transferequipment to isolategenerator from electricutility Useagroundfaultcircuit interrupter GFCI in anydampor highlyconductive area suchasmetaldecking or steelwork DONOT touchbarewiresor receptacles DONOT usegenerator withelectricalcordswhichareworn frayed bareor otherwise d...

Page 11: ...lcordslowlyuntil resistance is feltand thenpullrapidlyto avoidkickback NEVER startor stopengine with electrical devicespluggedin andturnedon If engine starts proceed to step 7 If engine fails to start proceed to step 6 6 Move choke lever to Half choke position and pull recoil handletwice If engine fails to start repeatsteps 5 thru 7 7 Slowly move choke lever to Run position If engine falters movec...

Page 12: ... grounded extension cords with the generator s 120 Volt duplex receptacle Inspect extension cords before each use Checkthe ratings of all extension cords before you use them Extensioncord sets used should be rated for 125 Volt AC loads at 20 Amps or greater for most electrical devices Some devices however may not requirethis type of extension cord Checkthe operator s manualsof those devicesfor the...

Page 13: ...Battery charging should be done in a dry location such as inside a garage 1 Plug charger into unit s 12V DO Battery Charger jack which is located on the start switch bracket Plug battery charger into a 120 Volt AC wall receptacle 4 _ _ _ j 2 Unplug charger from unit and wall outlet when generator is being started and while in operation 3 Keepcharger plugged in when generator is not in useto prolon...

Page 14: ...orrect and safe way to managegenerator power is to sequentially add loads as follows 1 With nothing connected to the generator start the engine as described in this manual 2 Plug in and turn on the first load preferablythe largest load you have 3 Permit the generator output to stabilize engine runs smoothly and attached deviceoperates properly 4 Plug in and turn on the next load 5 Again permit the...

Page 15: ...t power This difference is due to a variety of factors including but not limited to accessories air cleaner exhaust charging cooling carburetor fuel pump etc application limitations ambient operating conditions temperature humidity altitude and engine to engine variability Due to manufacturing and capacity limitations Briggs Stratton maysubstitute an engine of higher rated power for this Series en...

Page 16: ...ized dealer Seethe Emissions Warranty GEHERATOR MAINTENANCE Generator maintenanceconsists of keepingthe unit clean and dry Operateand store the unit in a clean dry environment where it will not beexposedto excessivedust dirt moisture or any corrosive vapors Cooling air slots in the generator must not becomeclogged with snow leaves or any other foreign material Checkthe cleanliness of the generator...

Page 17: ...utton once quickly will display Co clearing to zero This will clear any maintenance codes that have elapsed up to that point and they will begin timing again from zero 2 CA Pressing and holding the reset button for 2 seconds will display CA clearing all This clears all maintenancecodes even if they have not yet reached their service point and they will begin timing again from ze re If nominal load...

Page 18: ...ditions or in extremely hot weather change the oil more often CAUTION Avoid prolonged or repeatedskin contact with used motor oil Usedmotoroil hasbeenshownto causeskincancerin certain laboratory animals Thoroughly washexposed areas with soapandwater KEEPOUTOF REACHOF CHILDREN DON T POLLUTE CONSERVE RESOURCES RETURN USEDOIL TO COLLECTION CENTERS Changethe oil while the engine is still warm from run...

Page 19: ...r bracket 2 Remove four screws that attach spark arrester screen C 3 Inspect screen and obtain a replacement if torn perforated or otherwise damaged DO NOTuse a defective screen If screen is not damaged clean it with commercial solvent 4 Reattachscreen and muffler guard Air Coofing System Overtime debris may accumulate in cylinder cooling fins and cannot be observed without partial engine disassem...

Page 20: ... Removespark plug and pour about 1 ounce 30ml of clean engine oil into the cylinder Install spark plug and crank slowly to distribute oil WARNING _ Unintentional sparking can result in fire or _ electric shock NEVER crankengine with sparkplugremoved Generator 1 Cleangenerator as outlined in Generator Cleaning 2 Checkthat cooling air slots and openings on generator are openand unobstructed Other St...

Page 21: ...isconnect shorted electrical load 2 Contact Searsor other qualified service dealer 3 SeeDon t OverloadGenerator 4 Contact Searsor other qualified service dealer 1 Set switch to On 2 Turn fuel valveto Open position 3 Cleanor replace air cleaner 4 Fill fuel tank 5 Drain fuel tank and carburetor fill with fresh fuel 6 Connectwire to spark plug rough spark plug 7 Badspark plug 8 Water in fuel 9 Floode...

Page 22: ...DWER li _EEOE_ PI 3 0 LDAD MDNITOR 22 CC2 20AMP IR IIA 2e LED 44B DPI 1 22 S_IIC _GR liB WHITE PDWER 22 120V 20AMP CB3 44C _ 44A 20AMP DP2 IP B 44C B BRASS SCREW S SILVER SCREW GR GREEN SCREW TL X 44A 120 240V 30AMP P_ 4 SPARK PLUG ENG IGNITIDN RUN BLK __ ENG GRN RUN 0 SWITCH 55 IA 600V 22 sw L i3 _ O 1g 1 START RUN DCJ ...

Page 23: ...CRAFTSMAH6300 Watt AC Generator 580 326311 LQA M_N T_R 23 ...

Page 24: ...AH6310 Watt AC Generator 580 326311 Main Unit Exploded View 6O 69 75 44 55 62 52 51 T 40 54 41 32 53 DETAIL OF JACK ASSEMBLY COAXIAL DC tl 34 26 25 9 13 20 21 6 10 1 2_ 31 DETAIL OF BATTERY TRAY 5 J J _ 14 24 ...

Page 25: ... SCREW Self Driller 12 14 x 7 8 BRACKET Switch Jack BOLT Shoulder M6 1 0 w washer VALVE Fuel SOLENOID ASSY Tank Fuel includes Items 41 50 51 52 62 FUELCAP FreshStartTM Item Part 46 B4135GS 47 77395GS 48 195373GS 49 50 188333GS 51 194799GS 52 189235GS 53 194034GS 54 194448GS 55 197789GS 56 196908GS 57 58 200301GS 59 189164GS 60 195537GS 62 202997GS 68 198760GS 69 193043GS 70 87799GS 71 199152GS 73 ...

Page 26: ... 192241GS 17 3BO57GS 18 199528GS 19 199532GS Parts Not illustrated 201171GS 6 7 Description PANEL Control COVER Flip Outlets BOX Control Panel BOOT Circuit Breaker BREAKER Circuit 30A LIGHT Led Panel SCREW 3 x 6 Tapping CAP Breaker Circuit BREAKER Circuit 20A BAR Retaining PPPHS M3 0 5 x 18 OUTLET 120 240V 30A PALNUT 3 16 OUTLET 120V 15 20A NUT 5 32 Pal SCREW 3 5 x 14 Tapping GROMMET PLUG Dual Row...

Page 27: ...0GS 86308HGS 66386GS 66849GS 65791GS 81917GS 189769GS 74908GS 23762GS 199119GS Description ADAPTER Mounting Alternator ASSY Rotor Includes Item 8 STATOR RBC with O Ring p n 189197GS HHCS M6 1 0 x 140 SEMS ASSY Holder Brush TAPTITE M5 0 8 x 16 BEARING PIN Roll 4ram x 10 REGULATOR Voltage AVR SCREW M5 0 8 x 10 Taptite WASHER Shakeproof Ext 10 HARNESS Monitor Load 2 27 ...

Page 28: ...scription 1 196517GS WHEEL 2 WASHER 5 8 3 191267RGS AXLE 4 191265GS E RING 5 HHCS M81 25x20 6 67989GS NUT M8 FlangeSerrated 8 198629GS ASSY Supportw Mounts Parts Net illustrated 196157GS SUBKIT Hardware Items without part numbers are common fasteners and are available at local hardware stores 28 ...

Page 29: ...EHGIHE BrJggsand Stratto 210415 Exploded View 718A _o 529 415 21 12 21 725 742 746 _ 89 3O7 _ 24 _ 741 146 725A 728 _ 622 _ 1298 5O5 337 635 334 2g ...

Page 30: ...EHGIHE BrJggsand Stratto 210415 ExpJodedView 331 798 _ _ 1100_ 1022 4s 1230 222_ 604 633 914 356 1171 356A 914A_ 118 2o9 1404 0 564 633 633 _ _ 1270 130 221 51A_ 95 135 105 _ 117_ 369 _ 1O4 137 1127_ 30 ...

Page 31: ...Exploded View 8o2 697 121 CARBURETOROVERHAUL KIT 137 981 117 lo50 127 _ 163 104 _ 6330 358 ENGINEGASKET SET 868_ 20 163 883 304 305q_ 732 459 1095 VALVEGASKETSET 883__11 _ 51A _ _ _ 1022 868_ 51 977 CARBURETOR GASKET SET 7 _ 633 163 31 ...

Page 32: ...10 69 513 69 529 7_ 544 552 562 6 564 6 579 597 604 60B 615 616 622 632 633 635 689 697 718 71BA 725 72B 746 783 797 79B 801 802 803 851 868 883 914 914A 951 96B 975 977 102 105 117 121 121 32 OB ocker ingine BoW r Cleanercartridge whee awl Riction archer r Starter Cabte Starter _overnorControl Lever Drive Starter Clutch Drive ontro ter Cable awl Friction plate rive CoveO Starter _errnina Spark ug...

Page 33: ...33 ...

Page 34: ...Contrni Defects Warranty Provisions The following are specific provisions relative to your Emissions Control DefectsWarranty Coverage It is in addition to the Sears enginewarranty for non regulated enginesfound in the Operatingand MaintenanceInstructions 1 Warranted Parts Coverageunder this warranty extendsonly to the parts listed below the emissions control systems parts to the extent these parts...

Page 35: ...ate Engineis certified to beemission compliant for 250 hours of actual engine running time Extended Engineis certified to beemission compliant for 500 hours of actual engine running time Forexample a typical walk behind lawn mower is used 20 to 25 hours per year Therefore the EmissionsDurability Period of an engine with an intermediate rating would equateto 10to 12 years Certainengines will be cer...

Page 36: ...sta no sea posible parasu sustituci6n Garantialimitada de un ano adicional del generador Craftsman Duranteel segundo a_o a partir de ia fechade compra si cualquier pieza del generador faiia debido a defectos de materiales o mano de obra se suministrarA gratuitamente una nuevapieza Si desea quese instale la pieza deberApagar la mano de obra El periodo de garantia se reducirA a 90 dias desde la fech...

Page 37: ...aduras Qufmica K Qufmico Peligroso L Partes en Movimiento PELIGRO Su Contenidoes NOCIVO0 F_ SERINGERIDO Eviteel contacto con los ojos la piel o la ropa No tomar internamente Evite respirar la niebla o el vapor La exposici6n excesivade los ojos o la piel puede causar irritaci6n Mantengael estabilizador fuera del alcancede los ni_os El estabilizador de combustible es un quimico peligroso Latapa de c...

Page 38: ...decualquier forma NOopereel generador bajolaIluvia NOmaneje elgenerador o cablesel_ctricos mientrasest6 paradoenagua descalzo o cuandolasmanos y los piesest6n mojados NOpermitaquepersonas descalificadas o ni_osopereno sirvan algenerador ADVERTENCIA La combustible y sus vapores son extremadamente inflamables y explosivos El fuego o una explosi6n pueden causar quemaduras severas e inclusive la muert...

Page 39: ...conecte el alambre dela bujiay col6quelodondeno puedaentrarencontacto con labujia CUANDO PRUEBE LABUJJA DELMOTOR Utiliceuncornprobador de bujiashomologado NOcomprueba lachispasin labujiainstalada PRECAU ION Las velocidades de operaci6n en exceso aumentan los riesgos de heridas y da_ios al generador Las velocidades bajan en exceso imponen una carga muy esada NOcambie ninguna velocidad determinada E...

Page 40: ...ter BalancJn del Meter Deber_ estar en la posici6n On En para darle arranque al motor Col6quelo en la posici6n Off Apagado para detener un motor en funcionamiento Interrupter de Arranque Mantenga pulsado el interrupter en la posici6n Start Arranque durante un mAximo de 15 segundos cada vez que intente arrancar hasta conseguirlo Culatazo el Principio Interrupter Balancin del Motor Tapa del Dep6sito...

Page 41: ...entes herramientas para instalar estos componentes Llave de 13 mm Llave de cube de 13 mm Alicates Galasdeseguridad Instaleel juegederuedas conforme a lasinstrucciones siguientes llVlPORTANTE Elmontajedeljuegoderuedasse debecompletar antesdea_adiraceiteo combustible 1 Delelavueltaal generador deformaqueel motorquedearriba 2 Introduzca elejeatrav_sdelosdossoportes demontaje 3 Coloqueunaruedaencadaex...

Page 42: ...ulte Granalfitud o El motor admite gasolina con hasta un 10 de etanol gasohol o hasta un 15 de MTBE Otermetil terbutilico AViSO Evite el da_o del generador El fracaso para seguir Manual de Operario para el combustible reccomendations garantia de vacios NOutilice gasolina no autorizada por ejemplo E85 NOmezcle aceite con gasolina NOmodifique el motor para hacerlofuncionar con otros combustibles Par...

Page 43: ... tert butilfenol 128 39 2 y destilado de petr61eoalif_tico 64742 47 8 1 Introduzca el cartucho en el tapon 2 Presionehastaqueel cartuchoencajeensu posiciOn 3 Retirela lengiJeta paradejarla membrana aldescubierto ilVIPORTANTE NOretireel cierreplateado delotto lade 4 Vuelvaa colocareltapOndecombustible enel dep6sito 5 Compruebe peri6dicamente elcartuchoparaasegurarse deque sigaconteniendo estabiliza...

Page 44: ...y lascorriente deairepreponderantes cuandoelijala ubicaci6n delgenerador Conexi_n al Sistema El_ctrico de un Edificio Lasconexiones a efectosdealimentaci6n dereserva al sistema el_ctricode unedificiodebenser realizadas porun electricista cualificado Laconexi6n debeaislarlaalimentaci6n delgenerador delaalimentaci6n dela redpt blicay debecumplirtodaslasleyesy normasel_ctricas vigentes ADVERTENCIA Lo...

Page 45: ...ra evitar su retroceso NUNCAarranque o pare el motor cuando haya aparatos el_ctricos conectadosyen funcionamiento Si el motor arranca continQecon el paso 7 Si el motor no arranca procedacon el paso 6 6 Muevala palancade choque hasta la posiciOn Half media y accione dos veces la manija de retroceso Si el motornoarranca repitalos pasosdesde5 hasta7 7 Coloque la palanca de retroceso en la posiciOnde ...

Page 46: ...S CONECTORES Utilice exclusivamente cables prolongadores de alta calidad bien aislados y con conexiOna tierra para la toma doble de 120 V del generador Examinelos cables prolongadores antes de cada uso Revise las capacidadesdetodos las cordones de extension antes de usarlos Los juegos de cordones de extension utilizados deberAn tener una capacidad de 125 Voltios AC a 20 Amperios o mayor para la ma...

Page 47: ... cable amarillo como el tomacorriente de cable negro es de 20 Amperios NOTA Siga todas las instrucciones de seguridad cuando conecte cualquier cable de extension o aparato al generador C6mo al Uso el Corcel de Bateria El gato del corcel de la bateria del uso con el corcel proporcionado de bateria a mantienela bateria que comienza cargadoy se prepara para el uso Cargar de bateria se debe hacer en u...

Page 48: ...ia del generador es la de a_adir en secuencias las cargas como se describe a continuaci6n 1 Sin tener nada conectado al generador encienda el motor de la manera descrita en este manual 2 Conecte y encienda la primera carga preferiblemente la mayor que usted tenga 3 Permita que la salida del generador se estabilice el motor funciona suavemente y el aparato conectado al mismo trabaja adecuadamente 4...

Page 49: ...motores del mismo modelo Dada la amplia variedad de productos que utilizan nuestros motores y la multitud de factores ambientales que pueden afectar a su funcionamiento es posible que el motor de gasolina no desarrolle toda su potencia bruta nominal en determinados equipos potencia en la aplicaciOn o neta real Estadiferencia se debe entre otros a los siguientes factores accesorios filtro de aire e...

Page 50: ...ado pot elfabricante V_aseGarantfa deemisiones IVlantenimiento del Generador Elmantenimiento delgenerador consisteenconservarlaunidad limpiay seca Opere y almacene launidaden unambiente limpioy secodondenoserAexpuesta alpolvo suciedad humedad o vaporescorrosivos Las ranurasdelairedeenfriamiento del generador no deben estartapadas con nieve hojas o cualquierotro materialextra_os Revisefrecuentement...

Page 51: ...hasta ese punto y se volver_ a contar el tiempo nuevamente desde cero 2 CA Si se pulsa el bot6n de rearme reset y se Io mantiene pulsado durante 2 segundos se mostrar_ CA borrado total Esto borra todos los c6digos de mantenimiento incluso si no han alcanzado aOnsu punto de servicio y se volver_ a contar el tiempo nuevamentedesde cero Si aparecesimult_ neamentela carga nominaly un c6digo de manteni...

Page 52: ...ie el aceite cada 50 horas de ese momento enadelante Si est utilizando su generador bajo condiciones de extremasuciedad o polvo o en un clima demasiadocaliente haga el cambio de aceite m_ sfrecuentemente AVISO Evite el contacto prolongado o repetido de piel con aceite usado de motor El aceite usado del motor hasido mostrado al cancer de la piel de la causa en ciertos animalesdel laboratorio Comple...

Page 53: ...rigeraci6n de Aire Con el tiempo se pueden acumular residuos en las aletas de refrigeraci6n del cilindro y pasarinadvertidos mientras no se desmonte parcialmente el motor Recomendamos que encargue la limpieza del sistema de refrigeraci6n A a un distribuidor de servicio Sears siguiendo los intervalos recomendados consulte la secci6n Plan demantenimiento Es igualmente importante que no se acumulen r...

Page 54: ...1 onza deaceite de motor limpio en el interior del cilindro o Coloque la bujia y arranque lentamente para distribuir el aceite ADVERTENCIA f _l_ Chispear involuntario puede tener come resultado el fuego o el golpe elOctrico NUNCAarranque el motor sin la bujias instalada Generador Limpie el generador come est4 descrito en ParaLimpiar et Generador o Reviseque las ranuras para el aire de enfriamiento...

Page 55: ...eel interruptoren On En 2 Girelav_ lvula delcombustible a la EI motornoarranca o arranca y fun iona real Off 3 Depurador deairesucio 4 Sincombustible 5 Combustible vieja 6 El alambre de la bujia no est conectado 7 Bujia en mal estado 8 Agua en la combustible 9 Exceso decebado posici6n On 3 Limpie o reemplace el depurador de aire 4 Llene el tanque de combustible 5 Drene el tanque de combustible 116...

Page 56: ...56 ...

Page 57: ...57 ...

Page 58: ...en funcionamiento Disposicienes de la garautia de Sears Roebuck and Co contra defectos en el control de emisienes Las siguientes son disposiciones especificas relacionadas con la cobertura de la garantia contra defectos en el control de emisiones Se aiiade a la garantia de motores de Sears para motores no regulados que figura en las Instrucciones de uso y mantenimiento 1 Partes garantizadas La cob...

Page 59: ...va sobre emisiones durante 250 horas de funcionamiento real Prolongado El motor est_ certificado para cumplir la normativa sobre emisiones durante 500 horas de funcionamiento real Por ejemplo un cortac_sped con operario a pie se suele utilizar entre 20 y 25 horas al a_o Por tanto el Periodo de Burabilidad de las Ernisienes de un motor con clasificaci6n intermedia equivaldria a 10 12 a_os Algunos m...

Page 60: ..._H i_iiiiii iiiiiiiii iiiiiiiiiiiiiiiiiiiiii_H Our Home For repair of carry in items like vacuums lawn equipment and electronics call or go on line for the location of your nearest Sears Parts Repair Center iiiiiiiiiiiiiiiii iiiiiHi i ii_iiiii iiiiiii iiiiiiiii iiiiiiiiiiiii iiiiiii_ ii_iiiiiiiiiiiiiiiiiiii _ i iiiiiiiiiiiiiiiiiiiiiii i iiiiiiiiiiiiiiiiiiiiiii i iiiiiiiiiiiiiiiiiiiiiii i iiiiiiiii...

Reviews: