background image

Summary of Contents for 580.326301

Page 1: ...utilizar e producto leaeste manual y siga todas las Reglas de Seguridad e Instrucciones de Uso Sears Roebuck and Co Hoffman Estates _L 60179 U S A Visit our Craftsman website www craftsman com Part No 196822GS Draft 4 11 08 2005 o Safety o Assembly o Operation o Maintenance o Parts o EspaSol ...

Page 2: ...d prepaid by him This warranty does not cover normal maintenance and service and does not apply to a generator set alternator or engine or parts which have been subjected to improper or unauthorized installation or alteration misuse negligence accident overloading overspeeding improper maintenance repair or storage so as in SEARS s judgment to adversely affect its performance and reliability NORMA...

Page 3: ...plications Failure to use the appropriate U S Coast Guard approved generator could result in bodily injury and or property damage Hazard Symbols and Meanings Explosion Fire Electrical Shock Toxic Fumes Hot Surface Kickback WARNtNG Operate generator ONLY outdoors Keep exhaust gas from entering a confined area through windows doors ventilation intakes or other openings DO NOT operate generator insid...

Page 4: ... Regulation CFR Title 36 Parks Forests and Public Property require equipment powered by an internal combustion engine to have a spark arrester maintained in effective working order complying to USDA Forest service standard 5100 1C or later revision In the State of California a spark arrester is required under section 4442 of the California Public resources code Other states may have similar laws W...

Page 5: ... May be used to supply electrical power for the operation of 120 and or 240 Volt AC 30 Amp single phase 60 Hz electrical lighting appliance tool and motor loads Air Cleaner Filters intake air as it is drawn into the engine Choke Lever Used when starting a cold engine CircuEt Breakers AC Push to reset circuit breakers are provided to protect the generator against electrical overload Spark Arrester ...

Page 6: ...wrench with a 1 2 or 13mm socket Pliers Safety glasses Install the Wheel Kit as Follows 1 Tip generator so that engine end is up 2 Slide axle through both mounting brackets 3 Slide a wheel over the axle NOTE Be sure to install both wheels with the air pressure valve on the outboard side 4 Place a washer on axle and then place an e ring in axle groove 5 Install e ring with pliers squeezing from top...

Page 7: ...ndations Add Fuem NOTE This gasoline engine is certified to operate on gasoline Exhaust Emission Control System EM Engine Modifications WARNING WHEN ADDING FUEL Turn generator OFF and let it coo at least 2 minutes before removing fue cap Loosen cap slowly to relieve pressure in tank Fil fuel tank outdoors DO NOT overfill tank Allow space for fuel expansion Keep fue away from sparks open flames pil...

Page 8: ...ator from electric utility Use a ground circuit fault interrupter GFCI in any damp or highly conductive area such as metal decking or steel work DO NOT touch bare wires or receptacles DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while...

Page 9: ...sition If engine falters move choke lever to Half choke position until engine runs smoothly and then to Run position IMPORTANT If engine floods place choke lever in Run position and crank until engine starts NOTE If engine starts after 3 pulls but fails to run or if unit shuts down during operation make sure unit is on a level surface and check for proper oil level in crankcase This unit may be eq...

Page 10: ... protected against overload by a single 20 Amp push to reset circuit breaker Use each receptacle to operate 120 Volt AC single phase 60 Hz electrical loads requiring up to 2 400 watts 2 4 kW at 20 Amps of current 120 240 Volt AC 30 Amp Receptacle This is a full capacity receptacle it can supply the generator s full rated output from this sole outlet The outlet is protected by two 30 Amp push to re...

Page 11: ... generator power is to sequentially add loads as follows 1 With nothing connected to the generator start the engine as described in this manual 2 Plug in and turn on the first load preferably the largest load you have 3 Permit the generator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 ...

Page 12: ...mperature barometric pressure humidity fuel engine lubrication maximum governed engine speed individual engine to engine variability design of the particular peice of power equipment the manner in which the engine is operated engine run in to reduce friction and clean out of combustion chambers adjustments to the valves and carburetor and other factors The power ratings may also be adjusted based ...

Page 13: ...t or repair of the emission control devices and systems may be performed by any non road engine repair establishment or individual GENERATOR MAINTENANCE Generator maintenance consists of keeping the unit clean and dry Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust dirt moisture or any corrosive vapors Cooling air slots in the generator must not...

Page 14: ...ibed in Checking Oil Level 3 If needed slowly pour oil into oil fill opening to the point of overflowing at oil fill cap Changing Engine OH Change the oil after the first 5 hours of operation Change oil every 50 hours thereafter If you are using your generator under extremely dirty or dusty conditions or in extremely hot weather change the oil more often CAUTION Used motor oil has been shown to ca...

Page 15: ...uffler remove four screws that connect guard to muffler bracket 2 Remove four screws that attach spark arrester screen Mu mlr_NSpark Arrester Screen eat Shield 3 inspect screen and replace if torn perforated or otherwise damaged DO NOT use a defective screen If screen is not damaged clean it with commercial solvent 4 Reattach screen and muffler guard Air Coo_ing System Over time debris may accumul...

Page 16: ...ect Fue_ System Fuel Additive If adding a fuel additive fill the fuel tank with fresh fuel If only partially filled air in the tank will promote fuel deterioration during storage Engine and fuel can be stored up to 24 months with additive Add fuel additive following manufacturer s instructions Run the engine outdoors for several minutes to be sure that treated fuel has replaced the untreated fuel ...

Page 17: ...tion Set switch to On 6 Spark plug wire not connected Engine will not start or stars and runs rough 3 Clean or replace air cleaner 4 Fill fuel tank 5 Drain fuel tank fill with fresh fuel 6 Connect wire to spark plug to spark plug 7 Bad spark plug 8 Water in fuel 9 Overchoking 7 Replace spark plug 8 Drain fuel tank fill with fresh fuel 9 Open choke fully and crank engine 10 Low oil level 11 Excessi...

Page 18: ...AS SCREW S SILVER SCREW GR OREEN SCREW IP 22 POWER PI 2 CSl S B GR EB3 25A IP 11A 22 120 248V 30A POWER 120V 20A 44 30A I P CB4 44B _ _o 44A 25A 1P 44A CB2 32 _IOAT CHAR KR INPUT IA 600V DIODE 12V BATTERY i ii I ss STARTER _s l _6 ELECTRIC START SW TCH 18 ...

Page 19: ...CRAFTSMAN 6300 Watt AC Generator 580 326301 IBVDC FLOAT CHARGER NPUr SUPPLIED BATTERY 22 _A 8 0 44 pi 33 33 ELECTRIC START SWITCH NEITE PBSITIVE BRUSH IS CLUSEST TO BEARING _2 GROUND 11 22 STATOR 19 ...

Page 20: ...6301 Main Unit m E p_oded View DETAIL OF JACK ASSEMBLY COAXAL 9C 71 i i i i i DEIAiL OF BATTERY TRAY 75 78 DETAIl OF ELECTRIC S AR SWI CI 37 6 45 52 _39 78 STARTER 0 t IERMINAI ON BAiTERY 9O 5q 26 55 X 6 8 25 22 52 50 44 9OO 5 4 72 49 41 2O ...

Page 21: ...Muffler 900 HHCS 1 4 20 x 3 4 NUT 5 16 24 COVER Bearing Carrier w Cap KIT Fuel Hose NUT 1 4 20 SCREW 12 14 x 7 8 Self Drill SCREW 10 24 x 1 2 Cdmptite BRACKET Starter Switch KIT Hardware Tank Fuel KIT Fuel Valve Tank SWITCH Starter ASSY Tank Fuel Includes Items 41 50 51 52 CAP Fuel Gauge Part B4135GS 77395GS 195373GS 188333GS 194799GS 189235GS 194034GS 194448GS 197798GS 191757GS 194389GS 195680GS ...

Page 22: ...694GS 17 192241GS 18 75207PGS Description KIT Control Panel Lid CONTROL PANEL Compact OUTLET 120V 20Amp Duplex NUT Palnut 5 32 CAP Circuit Breaker BREAKER Circuit 30A OUTLET 120 240V Locking 30A NUT Palnut 3 16 PPPHS M3 0 5 x 18 BAR Retaining COVER Back Control Panel SCREW Tapping STC 3 x 18 HOUSING Receptacle SCREW Tapping 3 5 x 14 BREAKER Circuit 25A items without part numbers are common fastene...

Page 23: ...R 5 8 2 B4966GS WHEEL 3 191267GGS AXLE 5 8 x 23 62 4 191265GS EzR NG 5 8 5 HHCS M8 z 1 25 x 20 6 B187101GS LEG Support 7 191413GS VIBE MOUNT with Washer 8 HHCS 1 4 _20 x 1 9 52858GS NUT M8 1 25 Lock 10 192432GS NUT 1 4 20 Serrated Lock items without part numbers are common fasteners available at local hardware stores 23 ...

Page 24: ...059GS 191876GS 194006AGS 186060GS 86308HGS 66386GS 66849GS 22694GS 81917GS 193428AGS 189769GS 194274GS Description ADAPTER Mounting Alternator ROTOR STATOR RBC with OzRing p n 189197GS HHCS M6 z 1 0 x 140 SEMS ASSY Holder Brush TAPT TE M5 _ 0 8 x 16 RECEPTACLE 6 pin PIN Roll 4mm x 10 ASSY Wire Ground REGULATOR Voltage AVR HARNESS Wire Power 24 ...

Page 25: ...ENGINE 11 HP Briggs and Stratton 210415 Exploded View 718A 286 799 5_ f_ 5O5 22 _ _ 306 89 I 27 o 334 25 ...

Page 26: ...ggs and Stratton 210415 Exploded View 40 868 798_ 1100 8 1026_ 4s _ 347 188 2 604 36 914 1171 1_L_ 633 oy 137 9so 564A 564 _ 977 CARBURETOR 51 GASKET SET 137_ 633 163_ 121 CARBURETOR OVERHAUL KmT 137 _ 117 163_ 633 26 ...

Page 27: ..._1 HP Briggs and Stratton 210415 Exploded View 462 579 _ 797 503 310_ 544 2 1070 00 455 332_ 967 358 ENGINE GASKET SET 8680 2o1 5iA_ 883 i095 VALVE GASKET SET 304 305 58 732 456 689 45_ I i2i0 i21i 592 65 _ 27 ...

Page 28: ...ind Starter 718A 695178 Plug Oil Drain 727 697465 Screw Throttle Valve 732 691097 Shaft Throttle 741 691288 Kit Idle Speed 742 692564 Pin Float Hinge 746 694679 Valve Float Needle 783 693713 Valve Choke 797 693167 Jet Main Standard 798 690967 Jet Main High Altitude 799 690297 Kit Carburetor Overhaul 801 694482 Spacer Carburetor 802 691286 Carburetor 803 693757 Plug Welch 868 690968 Valve Throttle ...

Page 29: ...29 ...

Page 30: ...uck and Co Emissions Control Defects Warranty Provisions The following are specific provisions relative to your Emissions Control Defects Warranty Coverage It is in addition to the Sears engine warranty for non regulated engines found in the Operating and Maintenance Instructions 1 Warranted Parts Coverage under this warranty extends only to the parts listed below the emissions control systems par...

Page 31: ...ar Therefore the Emissions Durability Period of an engine with an intermediate rating would equate to 10 to 12 years The Air hdex is a calculated number describing the relative level of emissions for a specific engine family The lower the Air Index the cleaner the engine This information is displayed in graphical form on the emisions labe Emissions Compliance Period On Engine Emissions Compliance ...

Page 32: ... o las piezas que han sido su etas a instalaci6n a alteraci6n inadecuadads o desautorizadas abuso negligencia accidentes sobrecarga velocidad excesiva mantenimiento reparciones o almacenamiento inadecuados de modo que en la opini6n de SEARS afecten adversamente su rendimiento y confiabilidad Degaste Normal Como con todos los aparatos el6ctricos los motores necesitan servicio y reemplazo peri6dico ...

Page 33: ...es marinas El use de un generador no homologado por cuerpo de guardacostas de EE UU puede provocar tesiones y da_os materiales S mbo os de Pe igro y Significados Explosi6n Fuego Descarga Electrica Gases T6xicos Superficie Ca iente Retroceso ADVERTENC A Opere et generador SOLAMENTE al aire libre AsegL_rese de que los gases de escape no puedan entrar por ventanas puertas tomas de aire de ventilaciOn...

Page 34: ... uso en equipos m6viles ni en aplicaciones marinas CUANDO TRANSPORTE O REPARE EL EQUIPO Transporte o repare el equipo con et tanque de combustible vacio o con ta valvula para apagar et combustible apagada posici6n OFF Desconecte el cable de ta bujia CUANDO ALMACENE O GUARDE EL EQUIPO CON COMBUSTIBLE EN EL TANQUE Atmacene aJejado de calderas estufas calentadores de agua secadoras de ropa u otros ap...

Page 35: ...que penetra en el motor nterruptor BaJanc n Debera estar en la position On En para darle arranque al motor Col6quelo en la posici6n Off Apagado para detener un motor en funcionamiento Pamanca del Cebador Usada cuando se est dando arranque a un motor fr o Silenciador Apagachispas El silenciador disminuye el ruido de motor y est equipado con una pantalla apagachispas Silenciador Apagachispas Conecto...

Page 36: ...a las siguientes herramientas para instalar estos componentes Llave de 1 2 6 13 mm Llave de cubo de 1 2 6 13 mm Alicates Gafas de seguridad Instale el juego de ruedas conforrne alas instrucciones siguientes 1 Dele la vuelta al generador de forma que el motor quede arriba 2 Introduzca el eje a traves de los dos soportes de montaje 3 Monte una rueda en el eje NOTA AsegOrese de instalar ambas ruedas ...

Page 37: ...ertificado para funcionar con gasolina Sistema de control de emisiones de gases de escape EM Modificaciones de motor ADVERTENCIA CUANDO ANADA COMBUSTIBLE Apague el generador posici6n OFF y d6jeto enfnar at menos por 2 minutos antes de remover ta tapa de ta combustible Afloje ta tapa lentamente para dejar que la presi6n salga del tanque Llene el dep6sito de combustible a ta intemperie NO Ilene dema...

Page 38: ...a la falla del circuito de tierra GFCI en cualquier area bastante hOmeda o que sea altamente conductiva tales como terrazas de metal o trabajo hecho con acero NO toque los alambres pelados o receptacutos NO use un generador con cables et6ctricos que est6n malgastados rotos petados o da_ados de cuatquier forma NO opere et generador bajo la Ituvia NO maneje el generador o cables electricos mientras ...

Page 39: ...ra en funcionamiento asegOrese de que la unidad esta en una superficie plana y compruebe que el nive de aceite del cigOeBal es correcto La unidad puede equiparse con un dispositivo de proteccion de bajo nivel de aceite ADVERTENCIA NO toque las superficies calientes y evite los gases del escape a alta temperatura Permita que el equipo se enfrie antes de tocado Deje un espacio minimo de 152 cm 5 pie...

Page 40: ...posici6n Utilice cada uno de estos tomacorrientes para operar cargas el6ctricas de 120 Voltios AC monofasicas de 60 Hz que requieran hasta 2 400 vatios 2 4 kW a 20 Amperios de corriente Tomacorriente de 1201240 Vo_tios AC 30 Amperios Este es un tomacorriente de capacidad total Io que significa que usted puede tomar e vatiaje nominal total de este solo tomacordente Este es una tomacorriente tipo NE...

Page 41: ...s como se describe a continuaci6n 1 Sin tener nada conectado al generador encienda el motor de la manera descrita en este manual 2 Conecte y encienda la primera carga preferiblemente la mayor que usted tenga 3 Permita que la salida del generador se estabilice el motor funciona suavemente y el aparato conectado al mismo trabaja adecuadamente 4 Conecte y encienda la proxima carga 5 De nuevo permita ...

Page 42: ...idad maxima controlada del motor variaciones entre distintos motores del mismo modelo disefio del equipo mecanico utilizado manera de hacer funcionar el motor rodaje de motor para reducir la fricci6n y limpiar las camaras de combusti6n ajustes de las valvulas y el carburador etc Los valores de potencia nominal tambien se puede ajustar en funci6n de las comparaciones con otros motores similares uti...

Page 43: ...ONTROL DE EMlSlONES Cualquier establecimiento o individuo especializado en la reparacion de motores que no sean de automoci6n puede encargarse del mantenimiento la sustituci6n y la reparaci6n de los dispositivos y sistemas de control de emisiones Mantenimiento del Generador El mantenimiento del generador consiste en conservar la unidad limpia y seca Opere y almacene la unidad en un ambiente limpio...

Page 44: ...oque el generador sobre una superficie nivelada 2 Quite ei tapon de Ilenado de aceite y limpie o con un trapo 3 Compruebe que el aceite Ilega hasta e punto de desbordamiento en e orificio de Ilenado Adici6n de aceite de motor 1 AsegOrese de que la generador este en una superficie plana 2 Compruebe el nivel de aceite tal como se indica en la seccion Comprobacion del nivel de aceite 3 Si es necesari...

Page 45: ...ras de operaci6n o una vez al a_o Io que suceda primero Limpie o o reemplacelo mas a menudo si la unidad funciona bajo condiciones de suciedad o polvo excesivo Atienda a Fi tro de Aire 1 Afloje los tornillos y quite aire la cubierta mas limpia Quite papel el filtro Cartucho Cubierta 4 Reemplace la bujia si los electrodos estan picados quemados o si la porcelana esta rota Para su reemplazo 0nicamen...

Page 46: ...el Estado de California ta tey exige et uso de una pantalta apagachispas Seccidn 4442 dei C6digo de Recursos PQblicos de California En otros estados puede haber leyes similares en vigor Limpie e inspeccione e apagachispas de Ja siguiente manera 1 Para retirar la protecci6n del silenciador retire los cuatro tornillos que conectan la protecci6n a la m6nsula del silenciador __G ANALLA DE CHJSPAS S_ P...

Page 47: ...ue Vacie el dep6sito de combustible a la intemperie Mantenga la combustible alejada de chispas llamas abiertas pilotos calory otras fuentes de ignici6n NO encienda un cigarritto o fume Proteja el Sistema de Combustible 1 Retire toda la gasolina del tanque de combustible para evitar que se formen dep6sitos de goma en estas partes y causen posible real funcionamiento de motor 2 Haga funcionar e moto...

Page 48: ...ieja 6 El cable de la bujia no esta en malas la bujia 7 Bujia defectuosa 8 Agua en la gasolina 9 Sobrecebado 10 Mezcla de combustible excesivamente rica 3 4 5 6 7 8 9 10 On Limpie o reemplace el depurador de aire Llene o con combustible fresco Drene el tanque de gasolina Ilenelo con combustible fresco Conecte el cable a la bujia Reemplace la bujia Drene el tanque de gasolina Ilenelo con combustibl...

Page 49: ...49 ...

Page 50: ...or La garantia no dependera de ninguna prueba de emisiones en funcionamiento Disposiciones de la garant a de Sears Roebuck and Co contra defectos en el control de emisiones Las siguientes son disposiciones especificas relacionadas con la cobertura de la garantfa contra defectos en el control de emisiones Se a_ade a la garantfa de motores de Sears para motores no regulados que figura en las Instruc...

Page 51: ...e un motor con clasificaci6n intermedia equivaldria a 10 12 afios El indice de Aire es un valor calculado que indica el nivel relativo de emisiones de una gama concreta de motores Cuanto menor es el indice de Aire mas limpio es el motor Esta informacion se presenta en forma gr fica en la etiqueta de emisiones Periodo de Cump_imiento de _a Normativa de Emisiones en ia Etiqueta de CumpHmiento de Emi...

Page 52: ...ke vacuums lawn equipment and electronics call or go on line for the nearest Sears Parts Repair Center 1 800 488 1222 Anytime dayor night U S A only www sears com To purchase a protection agreement U S A or m intenanc agreement Canada on a pro uct terviced by Sears 1 800 827 6 55 U S A 1 800 361 6665 Canada Para pedir servicio der paraci6n AuCanada poos rvice f an ais a domicilio y para ordenar pi...

Reviews: